Enhanced porphyrin-based hypoxia imaging by temporal oversampling of delayed fluorescence signal.

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2025-02-01 Epub Date: 2025-01-28 DOI:10.1117/1.JBO.30.S2.S23903
Marien I Ochoa, Arthur F Petusseau, Matthew S Reed, Petr Brůža, Brian W Pogue
{"title":"Enhanced porphyrin-based hypoxia imaging by temporal oversampling of delayed fluorescence signal.","authors":"Marien I Ochoa, Arthur F Petusseau, Matthew S Reed, Petr Brůža, Brian W Pogue","doi":"10.1117/1.JBO.30.S2.S23903","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Protoporphyrin IX (PpIX) delayed fluorescence (DF) is inversely related to the oxygen present in tissues and has potential as a novel biomarker for surgical guidance and real-time tissue metabolism assessment. Despite the unique promise of this technique, its successful clinical translation is limited by the low intensity emitted.</p><p><strong>Aim: </strong>We developed a systematic study of ways to increase the PpIX DF signal through acquisition sampling changes, allowing optimized imaging at video rates.</p><p><strong>Approach: </strong>To accomplish signal increase, time-gating signal compression was achieved through changes in pulse frequency and power density, using sampling rates that are faster than the decay rate of the signal. The increased signal yield was tested and validated <i>in vitro</i> and then demonstrated <i>in vivo</i>, with comparison to settings that sample the full lifetime emission decay.</p><p><strong>Results: </strong>Results <i>in vitro</i> and <i>in vivo</i> demonstrated that optimized timing could increase the detected intensity by a factor of 7. The images showed results that were superior than when sampling the full DF lifetime decay.</p><p><strong>Conclusions: </strong>The proposed timing optimization enhances PpIX-based DF real-time imaging of tissue hypoxia. By increasing sampling frequency and adjusting the acquisition gate and pulse width, the collected signal intensity improved sevenfold, demonstrated both <i>in vitro</i> and <i>in vivo</i>. The technique was shown to enable better visualization of small and anatomically challenging hypoxic structures. The improved target-to-background ratio and compatibility with pressure-enhanced sensing of tissue oxygen technique were demonstrated.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"30 Suppl 2","pages":"S23903"},"PeriodicalIF":3.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11774257/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.30.S2.S23903","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Protoporphyrin IX (PpIX) delayed fluorescence (DF) is inversely related to the oxygen present in tissues and has potential as a novel biomarker for surgical guidance and real-time tissue metabolism assessment. Despite the unique promise of this technique, its successful clinical translation is limited by the low intensity emitted.

Aim: We developed a systematic study of ways to increase the PpIX DF signal through acquisition sampling changes, allowing optimized imaging at video rates.

Approach: To accomplish signal increase, time-gating signal compression was achieved through changes in pulse frequency and power density, using sampling rates that are faster than the decay rate of the signal. The increased signal yield was tested and validated in vitro and then demonstrated in vivo, with comparison to settings that sample the full lifetime emission decay.

Results: Results in vitro and in vivo demonstrated that optimized timing could increase the detected intensity by a factor of 7. The images showed results that were superior than when sampling the full DF lifetime decay.

Conclusions: The proposed timing optimization enhances PpIX-based DF real-time imaging of tissue hypoxia. By increasing sampling frequency and adjusting the acquisition gate and pulse width, the collected signal intensity improved sevenfold, demonstrated both in vitro and in vivo. The technique was shown to enable better visualization of small and anatomically challenging hypoxic structures. The improved target-to-background ratio and compatibility with pressure-enhanced sensing of tissue oxygen technique were demonstrated.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信