Comparisons of oscillatory potentials and 30 Hz flicker electroretinograms for discriminating eyes with diabetic retinopathy from normal eyes.

IF 2.1 3区 医学 Q2 OPHTHALMOLOGY
Mana Gonmori, Shigeki Machida, Shinya Inoue, Satoshi Ebihara, Keita Misu
{"title":"Comparisons of oscillatory potentials and 30 Hz flicker electroretinograms for discriminating eyes with diabetic retinopathy from normal eyes.","authors":"Mana Gonmori, Shigeki Machida, Shinya Inoue, Satoshi Ebihara, Keita Misu","doi":"10.1007/s10384-024-01154-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the amplitudes and implicit times of the oscillatory (OPs) of the full-field electroretinograms (ERGs) to those of the 30 Hz flicker ERGs in differentiating eyes with diabetic retinopathy (DR) from normal eyes.</p><p><strong>Study design: </strong>Single-center observational study.</p><p><strong>Methods: </strong>Full-field ERGs were recorded in 55 patients with Type 2 diabetes mellitus (DM) and 20 normal control subjects. The amplitudes and implicit times of the OPs and of the 30 Hz flicker ERGs were measured. Optical coherence tomography angiography (OCTA) was used to record 3×3 mm enface images of the retina from which the vascular density (VD) of the superficial capillary plexus (SCP) and deep capillary plexus (DCP) were obtained. The receiver operating characteristic (ROC) curves were used to determine the ability of each ERG parameter to discriminate diseased eyes from normal eyes. The significance of the correlations between each ERG parameter and the VD of the SCP and DCP was determined.</p><p><strong>Results: </strong>The area under the ROC curves (AUCs) was significantly larger for the implicit times than for the amplitudes of each ERG component (P<0.005). There were no significant differences in the AUCs between the OPs and 30 Hz flicker ERGs in differentiating eyes with DM or DR from normal eyes. The implicit time of the 30 Hz flicker ERG had the highest significant correlation coefficient with the VD of the DCP (r = - 0.31, P <0.001).</p><p><strong>Conclusions: </strong>The OPs and 30 Hz flicker ERGs have equal ability in differentiating eyes with DR from normal eyes but with better ability for the implicit times than the amplitudes. The implicit time of the 30 Hz flicker ERG is the most sensitive parameter that is correlated with the reduction of VD among the full-field ERG components.</p>","PeriodicalId":14563,"journal":{"name":"Japanese Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10384-024-01154-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the amplitudes and implicit times of the oscillatory (OPs) of the full-field electroretinograms (ERGs) to those of the 30 Hz flicker ERGs in differentiating eyes with diabetic retinopathy (DR) from normal eyes.

Study design: Single-center observational study.

Methods: Full-field ERGs were recorded in 55 patients with Type 2 diabetes mellitus (DM) and 20 normal control subjects. The amplitudes and implicit times of the OPs and of the 30 Hz flicker ERGs were measured. Optical coherence tomography angiography (OCTA) was used to record 3×3 mm enface images of the retina from which the vascular density (VD) of the superficial capillary plexus (SCP) and deep capillary plexus (DCP) were obtained. The receiver operating characteristic (ROC) curves were used to determine the ability of each ERG parameter to discriminate diseased eyes from normal eyes. The significance of the correlations between each ERG parameter and the VD of the SCP and DCP was determined.

Results: The area under the ROC curves (AUCs) was significantly larger for the implicit times than for the amplitudes of each ERG component (P<0.005). There were no significant differences in the AUCs between the OPs and 30 Hz flicker ERGs in differentiating eyes with DM or DR from normal eyes. The implicit time of the 30 Hz flicker ERG had the highest significant correlation coefficient with the VD of the DCP (r = - 0.31, P <0.001).

Conclusions: The OPs and 30 Hz flicker ERGs have equal ability in differentiating eyes with DR from normal eyes but with better ability for the implicit times than the amplitudes. The implicit time of the 30 Hz flicker ERG is the most sensitive parameter that is correlated with the reduction of VD among the full-field ERG components.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.80
自引率
8.30%
发文量
65
审稿时长
6-12 weeks
期刊介绍: The Japanese Journal of Ophthalmology (JJO) was inaugurated in 1957 as a quarterly journal published in English by the Ophthalmology Department of the University of Tokyo, with the aim of disseminating the achievements of Japanese ophthalmologists worldwide. JJO remains the only Japanese ophthalmology journal published in English. In 1997, the Japanese Ophthalmological Society assumed the responsibility for publishing the Japanese Journal of Ophthalmology as its official English-language publication. Currently the journal is published bimonthly and accepts papers from authors worldwide. JJO has become an international interdisciplinary forum for the publication of basic science and clinical research papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信