Optimisation of low and ultra-low dose scanning protocols for ultra-extended field of view PET in a real-world clinical setting.

IF 3.5 2区 医学 Q2 ONCOLOGY
Johanna Ingbritsen, Jason Callahan, Hugh Morgan, Melissa Munro, Robert E Ware, Rodney J Hicks
{"title":"Optimisation of low and ultra-low dose scanning protocols for ultra-extended field of view PET in a real-world clinical setting.","authors":"Johanna Ingbritsen, Jason Callahan, Hugh Morgan, Melissa Munro, Robert E Ware, Rodney J Hicks","doi":"10.1186/s40644-025-00823-x","DOIUrl":null,"url":null,"abstract":"<p><p>True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility. Low-dose (1 MBq/kg) and ultra-low dose (0.5 MBq/g) cohorts, each of 20 patients were scanned in a single bed position for 10 and 15 min respectively with list-mode data acquisition. These data were then reconstructed simulating progressively shorter acquisition times down to 30 s and 1 min, respectively and then reviewed by 2 experienced PET readers who selected the shortest optimal and minimal acquisition durations based on personal preferences. Quantitative analysis was also performed of image noise to assess how this correlated with qualitative preferences. At the consensus minimum acquisition durations at both dosing levels, the coefficient of variance in the liver as a measure of image noise was 10% or less and there was minimal reduction in this measure between the optimal and longest acquisition durations. These data support the reduction in both administered activity and scan acquisition times for routine clinical FDG PET/CT on the Quadra providing efficient workflows and low radiation doses to staff and patients, while achieving high quality images.</p>","PeriodicalId":9548,"journal":{"name":"Cancer Imaging","volume":"25 1","pages":"7"},"PeriodicalIF":3.5000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11780987/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancer Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40644-025-00823-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility. Low-dose (1 MBq/kg) and ultra-low dose (0.5 MBq/g) cohorts, each of 20 patients were scanned in a single bed position for 10 and 15 min respectively with list-mode data acquisition. These data were then reconstructed simulating progressively shorter acquisition times down to 30 s and 1 min, respectively and then reviewed by 2 experienced PET readers who selected the shortest optimal and minimal acquisition durations based on personal preferences. Quantitative analysis was also performed of image noise to assess how this correlated with qualitative preferences. At the consensus minimum acquisition durations at both dosing levels, the coefficient of variance in the liver as a measure of image noise was 10% or less and there was minimal reduction in this measure between the optimal and longest acquisition durations. These data support the reduction in both administered activity and scan acquisition times for routine clinical FDG PET/CT on the Quadra providing efficient workflows and low radiation doses to staff and patients, while achieving high quality images.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Cancer Imaging
Cancer Imaging ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
7.00
自引率
0.00%
发文量
66
审稿时长
>12 weeks
期刊介绍: Cancer Imaging is an open access, peer-reviewed journal publishing original articles, reviews and editorials written by expert international radiologists working in oncology. The journal encompasses CT, MR, PET, ultrasound, radionuclide and multimodal imaging in all kinds of malignant tumours, plus new developments, techniques and innovations. Topics of interest include: Breast Imaging Chest Complications of treatment Ear, Nose & Throat Gastrointestinal Hepatobiliary & Pancreatic Imaging biomarkers Interventional Lymphoma Measurement of tumour response Molecular functional imaging Musculoskeletal Neuro oncology Nuclear Medicine Paediatric.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信