Accuracy of a Novel High-Throughput "Car Blood Pressure" Measurement Protocol.

IF 3.2 3区 医学 Q2 PERIPHERAL VASCULAR DISEASE
Neiberg de Alcantara Lima, Shaun Cardozo, Andrew Johnson, Brian Reed, Steven Korzeniewski, Philip D Levy, Robert D Brook
{"title":"Accuracy of a Novel High-Throughput \"Car Blood Pressure\" Measurement Protocol.","authors":"Neiberg de Alcantara Lima, Shaun Cardozo, Andrew Johnson, Brian Reed, Steven Korzeniewski, Philip D Levy, Robert D Brook","doi":"10.1093/ajh/hpaf016","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>More than one in three adults with hypertension in the United States are unaware of their condition, highlighting the importance of large-scale screening campaigns. Currently, the identification of hypertension is largely limited to medical settings. To help overcome this barrier, we developed a novel high-throughput screening protocol that measures blood pressure (BP) while patients remain seated in an automobile (\"car-BP\"). The aim of this study was to provide an initial assessment of the accuracy of car-BP.</p><p><strong>Methods: </strong>Three BP readings were determined in a clinic exam room before and after three BP readings were taken while patients were seated in a parked car outside (n=100 participants). The same validated device model (Omron HEM-907XL) and BP measurement methods adhering to guidelines were used in both scenarios. The average of all 6 clinic readings was compared to the average of the 3 car-BP readings in each individual.</p><p><strong>Results: </strong>Mean clinic and car-BP readings were 120.9 ± 16.2/78.0 ± 9.9 and 118.9 ± 15.2/76.0 ± 10.0 mm Hg, respectively. The paired mean and absolute mean differences in systolic BP levels between methods were -1.92 mm Hg (95% confidence interval (CI) -3.2 to -0.7 mm Hg) and 4.8 mm Hg (95%CI 3.8 to 5.6 mm Hg), respectively. A total of 85% of participants had both systolic and diastolic BP levels ≤10 mm Hg different between measurement scenarios (meeting the a priori determined study primary outcome).</p><p><strong>Conclusions: </strong>Car-BP represents an innovative and accessible approach for potential large-scale hypertension screening campaigns.</p>","PeriodicalId":7578,"journal":{"name":"American Journal of Hypertension","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajh/hpaf016","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: More than one in three adults with hypertension in the United States are unaware of their condition, highlighting the importance of large-scale screening campaigns. Currently, the identification of hypertension is largely limited to medical settings. To help overcome this barrier, we developed a novel high-throughput screening protocol that measures blood pressure (BP) while patients remain seated in an automobile ("car-BP"). The aim of this study was to provide an initial assessment of the accuracy of car-BP.

Methods: Three BP readings were determined in a clinic exam room before and after three BP readings were taken while patients were seated in a parked car outside (n=100 participants). The same validated device model (Omron HEM-907XL) and BP measurement methods adhering to guidelines were used in both scenarios. The average of all 6 clinic readings was compared to the average of the 3 car-BP readings in each individual.

Results: Mean clinic and car-BP readings were 120.9 ± 16.2/78.0 ± 9.9 and 118.9 ± 15.2/76.0 ± 10.0 mm Hg, respectively. The paired mean and absolute mean differences in systolic BP levels between methods were -1.92 mm Hg (95% confidence interval (CI) -3.2 to -0.7 mm Hg) and 4.8 mm Hg (95%CI 3.8 to 5.6 mm Hg), respectively. A total of 85% of participants had both systolic and diastolic BP levels ≤10 mm Hg different between measurement scenarios (meeting the a priori determined study primary outcome).

Conclusions: Car-BP represents an innovative and accessible approach for potential large-scale hypertension screening campaigns.

求助全文
约1分钟内获得全文 求助全文
来源期刊
American Journal of Hypertension
American Journal of Hypertension 医学-外周血管病
CiteScore
6.90
自引率
6.20%
发文量
144
审稿时长
3-8 weeks
期刊介绍: The American Journal of Hypertension is a monthly, peer-reviewed journal that provides a forum for scientific inquiry of the highest standards in the field of hypertension and related cardiovascular disease. The journal publishes high-quality original research and review articles on basic sciences, molecular biology, clinical and experimental hypertension, cardiology, epidemiology, pediatric hypertension, endocrinology, neurophysiology, and nephrology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信