Evaluating temperature dynamics: a single-center prospective randomized pilot study of holmium versus thulium laser fiber for renal stones.

IF 2.8 2区 医学 Q2 UROLOGY & NEPHROLOGY
Vaibhavkumar Patel, Kshitij Raghuvanshi, Rajeev Chaudhari
{"title":"Evaluating temperature dynamics: a single-center prospective randomized pilot study of holmium versus thulium laser fiber for renal stones.","authors":"Vaibhavkumar Patel, Kshitij Raghuvanshi, Rajeev Chaudhari","doi":"10.1007/s00345-025-05466-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We aimed to evaluate and compare the rise in the temperature for the safety of the kidney parenchyma on firing the Holmium: Yttrium Aluminium Garnet laser and the Thulium Fiber Laser during laser lithotripsy in humans.</p><p><strong>Method: </strong>We included 30 pre-stented patients with renal calculi undergoing Retrograde intra-renal surgery. They were randomized into two groups - 15 patients underwent holmium laser lithotripsy and 15 patients underwent TFL laser lithotripsy. We used Philips paediatric esophageal probe to measure rise in temperature on firing holmium or TFL laser with irrigation at 10 ml/min and pressure at 100 mmHg. Different laser settings were used.</p><p><strong>Result: </strong>The mean size of the calculi was 0.8 mm. The rise in temperature with holmium and TFL lasers depended on the firing time and irrigation flow, keeping power constant. On continuous firing for 10s, 20s, and 30s, the average rise in temperature went up to 28.67 °C, 29.70 °C, and 37.17 °C with holmium and with TFL it was 28.77 °C, 29.83 °C, and 37.62 °C, respectively. The difference in rise in temperature between two groups was statistically insignificant with p-values > 0.05. The maximum temperature reached with TFL was 39.4 °C with a 30s lasing time, and that with Ho: YAG was 38.9 °C.</p><p><strong>Conclusions: </strong>The rise in temperature was almost equivalent with holmium and TFL. Hence, both Ho: YAG and TFL can be safely used in laser lithotripsy. Adequate irrigation is a must during the surgery. The continuous lasing time should be strictly restricted to less than 20s.</p>","PeriodicalId":23954,"journal":{"name":"World Journal of Urology","volume":"43 1","pages":"91"},"PeriodicalIF":2.8000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00345-025-05466-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: We aimed to evaluate and compare the rise in the temperature for the safety of the kidney parenchyma on firing the Holmium: Yttrium Aluminium Garnet laser and the Thulium Fiber Laser during laser lithotripsy in humans.

Method: We included 30 pre-stented patients with renal calculi undergoing Retrograde intra-renal surgery. They were randomized into two groups - 15 patients underwent holmium laser lithotripsy and 15 patients underwent TFL laser lithotripsy. We used Philips paediatric esophageal probe to measure rise in temperature on firing holmium or TFL laser with irrigation at 10 ml/min and pressure at 100 mmHg. Different laser settings were used.

Result: The mean size of the calculi was 0.8 mm. The rise in temperature with holmium and TFL lasers depended on the firing time and irrigation flow, keeping power constant. On continuous firing for 10s, 20s, and 30s, the average rise in temperature went up to 28.67 °C, 29.70 °C, and 37.17 °C with holmium and with TFL it was 28.77 °C, 29.83 °C, and 37.62 °C, respectively. The difference in rise in temperature between two groups was statistically insignificant with p-values > 0.05. The maximum temperature reached with TFL was 39.4 °C with a 30s lasing time, and that with Ho: YAG was 38.9 °C.

Conclusions: The rise in temperature was almost equivalent with holmium and TFL. Hence, both Ho: YAG and TFL can be safely used in laser lithotripsy. Adequate irrigation is a must during the surgery. The continuous lasing time should be strictly restricted to less than 20s.

求助全文
约1分钟内获得全文 求助全文
来源期刊
World Journal of Urology
World Journal of Urology 医学-泌尿学与肾脏学
CiteScore
6.80
自引率
8.80%
发文量
317
审稿时长
4-8 weeks
期刊介绍: The WORLD JOURNAL OF UROLOGY conveys regularly the essential results of urological research and their practical and clinical relevance to a broad audience of urologists in research and clinical practice. In order to guarantee a balanced program, articles are published to reflect the developments in all fields of urology on an internationally advanced level. Each issue treats a main topic in review articles of invited international experts. Free papers are unrelated articles to the main topic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信