Femtosecond Laser-Assisted Pterygium Surgery Using a Customized Algorithm for Trapezoidal Conjunctival Grafts.

IF 1.9 3区 医学 Q2 OPHTHALMOLOGY
Shayne S Tan, Yu-Chi Liu, Evelina J Y Han, Hon Shing Ong, Marcus Ang, Andri K Riau, Jodhbir S Mehta
{"title":"Femtosecond Laser-Assisted Pterygium Surgery Using a Customized Algorithm for Trapezoidal Conjunctival Grafts.","authors":"Shayne S Tan, Yu-Chi Liu, Evelina J Y Han, Hon Shing Ong, Marcus Ang, Andri K Riau, Jodhbir S Mehta","doi":"10.1097/ICO.0000000000003815","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Conjunctival autografts (CAGs) are the gold standard treatment after pterygium resection, but it is challenging to achieve consistently thin Tenon-free CAGs with manual dissection. We herein report the reproducibility and clinical outcomes of a novel algorithm to produce customizable trapezoidal CAGs using femtosecond laser (femtosecond lasers)-assisted pterygium surgery.</p><p><strong>Methods: </strong>We first tested this algorithm in 4 pig eyes to show reproducibility. We then treated 15 pterygia of 14 patients using this algorithm. After manual pterygium excision, 7-mm x 10-mm preset trapezoidal CAGs were dissected with the Ziemer FEMTO LDV Z8 laser set at a 60 μm depth. The achieved thickness was measured with intraoperative optical coherence tomography, and the achieved area was calculated.</p><p><strong>Results: </strong>For the pig eyes, the average CAG length and width were 9.8 ± 0.1 mm and 7.3 ± 0.04 mm, respectively, with a mean deviation of 7.3% ± 3.2% and 7.5% ± 4.1%, respectively. The mean age of the patients was 56.8 ± 7.3 years. The programmed and achieved CAG areas were 70 mm2 and 72.5 ± 3.9 mm2, respectively, with a mean deviation of 4.7% ± 4.6%. The eventual CAG thickness was 59.5 ± 3.9 μm, with a minimal deviation of 4.4% ± 4.6%. The average time to remove the FSL-prepared CAG to unfold it onto the cornea was 19.9 ± 14.9 seconds. At the postoperative month 3 follow-up, no postoperative complications or recurrences occurred, and all donor CAG sites had completely healed.</p><p><strong>Conclusions: </strong>This novel algorithm using the FEMTO LDV Z8 in Femtosecond Laser-Assisted Pterygium Surgery provides consistent and customizable trapezoid ultrathin CAGs. Longer follow-up and larger cohorts will need to be studied for recurrence and complication rates.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003815","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Conjunctival autografts (CAGs) are the gold standard treatment after pterygium resection, but it is challenging to achieve consistently thin Tenon-free CAGs with manual dissection. We herein report the reproducibility and clinical outcomes of a novel algorithm to produce customizable trapezoidal CAGs using femtosecond laser (femtosecond lasers)-assisted pterygium surgery.

Methods: We first tested this algorithm in 4 pig eyes to show reproducibility. We then treated 15 pterygia of 14 patients using this algorithm. After manual pterygium excision, 7-mm x 10-mm preset trapezoidal CAGs were dissected with the Ziemer FEMTO LDV Z8 laser set at a 60 μm depth. The achieved thickness was measured with intraoperative optical coherence tomography, and the achieved area was calculated.

Results: For the pig eyes, the average CAG length and width were 9.8 ± 0.1 mm and 7.3 ± 0.04 mm, respectively, with a mean deviation of 7.3% ± 3.2% and 7.5% ± 4.1%, respectively. The mean age of the patients was 56.8 ± 7.3 years. The programmed and achieved CAG areas were 70 mm2 and 72.5 ± 3.9 mm2, respectively, with a mean deviation of 4.7% ± 4.6%. The eventual CAG thickness was 59.5 ± 3.9 μm, with a minimal deviation of 4.4% ± 4.6%. The average time to remove the FSL-prepared CAG to unfold it onto the cornea was 19.9 ± 14.9 seconds. At the postoperative month 3 follow-up, no postoperative complications or recurrences occurred, and all donor CAG sites had completely healed.

Conclusions: This novel algorithm using the FEMTO LDV Z8 in Femtosecond Laser-Assisted Pterygium Surgery provides consistent and customizable trapezoid ultrathin CAGs. Longer follow-up and larger cohorts will need to be studied for recurrence and complication rates.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Cornea
Cornea 医学-眼科学
CiteScore
5.20
自引率
10.70%
发文量
354
审稿时长
3-6 weeks
期刊介绍: For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references. Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信