Revati Varma, Catherine E Williams, Ethan S McClain, Kent R Bailey, Tamas Ordog, Adil E Bharucha
{"title":"Utility of a <sup>13</sup>C-Spirulina Stable Isotope Gastric Emptying Breath Test in Diabetes Mellitus.","authors":"Revati Varma, Catherine E Williams, Ethan S McClain, Kent R Bailey, Tamas Ordog, Adil E Bharucha","doi":"10.1111/nmo.15008","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.</p><p><strong>Methods: </strong>Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and <sup>13</sup>C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart. We assessed the accuracy of <sup>13</sup>C-spirulina GEBT excretion rate (percent dose multiplied by 1000 [kPCD] min<sup>-1</sup>) values to predict scintigraphic half-life and distinguish between normal, delayed, and accelerated GE and the intraindividual reproducibility of the GEBT.</p><p><strong>Key results: </strong>Scintigraphy revealed normal, delayed, and accelerated GE, respectively, in 17 (30%), 29 (52%), and 10 (18%) test results. GE T½ values measured with scintigraphy and GEBT were highly concordant within individuals; the intraindividual reproducibility was 34% (scintigraphy) and 15% (GEBT). Compared to current criteria, the kPCD150 (150 min) and kPCD180 values provided equally sensitive (90%) and more specific (81% vs. 67%) approach for distinguishing between delayed versus normal/accelerated GE. A new metric (kPCD60-kPCD15 min) was 90% sensitive and 83% specific for distinguishing between accelerated versus normal/delayed GE. These findings were used to create nomograms and an algorithm for interpreting GEBT results.</p><p><strong>Conclusions and inferences: </strong>Among patients with poorly controlled diabetes, the <sup>13</sup>C-spirulina GEBT can accurately and precisely assess GE and effectively distinguish between normal, delayed, and accelerated GE.</p>","PeriodicalId":19123,"journal":{"name":"Neurogastroenterology and Motility","volume":" ","pages":"e15008"},"PeriodicalIF":3.5000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurogastroenterology and Motility","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/nmo.15008","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.
Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and 13C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart. We assessed the accuracy of 13C-spirulina GEBT excretion rate (percent dose multiplied by 1000 [kPCD] min-1) values to predict scintigraphic half-life and distinguish between normal, delayed, and accelerated GE and the intraindividual reproducibility of the GEBT.
Key results: Scintigraphy revealed normal, delayed, and accelerated GE, respectively, in 17 (30%), 29 (52%), and 10 (18%) test results. GE T½ values measured with scintigraphy and GEBT were highly concordant within individuals; the intraindividual reproducibility was 34% (scintigraphy) and 15% (GEBT). Compared to current criteria, the kPCD150 (150 min) and kPCD180 values provided equally sensitive (90%) and more specific (81% vs. 67%) approach for distinguishing between delayed versus normal/accelerated GE. A new metric (kPCD60-kPCD15 min) was 90% sensitive and 83% specific for distinguishing between accelerated versus normal/delayed GE. These findings were used to create nomograms and an algorithm for interpreting GEBT results.
Conclusions and inferences: Among patients with poorly controlled diabetes, the 13C-spirulina GEBT can accurately and precisely assess GE and effectively distinguish between normal, delayed, and accelerated GE.
期刊介绍:
Neurogastroenterology & Motility (NMO) is the official Journal of the European Society of Neurogastroenterology & Motility (ESNM) and the American Neurogastroenterology and Motility Society (ANMS). It is edited by James Galligan, Albert Bredenoord, and Stephen Vanner. The editorial and peer review process is independent of the societies affiliated to the journal and publisher: Neither the ANMS, the ESNM or the Publisher have editorial decision-making power. Whenever these are relevant to the content being considered or published, the editors, journal management committee and editorial board declare their interests and affiliations.