A cross-sectional study comparing passive and eccentric modes of an isokinetic dynamometer to assess eccentric torque in trained athletes: Methodological considerations

Anne Delextrat, Andreu Sastre-Munar, Mark de Ste Croix, Gregory Walsh
{"title":"A cross-sectional study comparing passive and eccentric modes of an isokinetic dynamometer to assess eccentric torque in trained athletes: Methodological considerations","authors":"Anne Delextrat,&nbsp;Andreu Sastre-Munar,&nbsp;Mark de Ste Croix,&nbsp;Gregory Walsh","doi":"10.1002/ejsc.12248","DOIUrl":null,"url":null,"abstract":"<p>Some technical limitations to using the eccentric mode to measure peak eccentric strength of the hamstrings (PTH<sub>ecc</sub>) were raised. PTH<sub>ecc</sub> also has limited validity to predict performance or injury risk factor. Therefore, our aim was to compare PTH<sub>ecc</sub> and other isokinetic variables tested in the eccentric and passive modes. Twenty male hockey players (20.2 ± 1.1 years; 179.7 ± 6.9 cm; 73.4 ± 7.1 kg and 12.2 ± 3.4% of body fat) performed maximal eccentric contractions of the hamstrings at 60°·s<sup>−1</sup> (three repetitions) and 180°·s<sup>−1</sup> (five repetitions) on both legs and using the eccentric mode and the passive mode (automatic movement of the lever arm) of the Biodex System 4 isokinetic dynamometer. The following variables were measured: PTH<sub>ecc</sub>, the angle of peak torque (APT,°), angle-specific H<sub>ecc</sub> torque at intervals of 10° and the rate of torque development (RTD) in the first 50 ms and the first 100 ms. The main results showed that compared to the eccentric mode, the passive mode led to a significantly greater PTH<sub>ecc</sub> in the non-dominant leg only and significantly smaller APT, RTD and angle-specific H<sub>ecc</sub> at angles close to knee flexion. In contrast, significantly greater angle-specific H<sub>ecc</sub> was observed in the passive mode at angles close to extension (10°–40°). This suggests that, although eccentric or concentric modes can be used to compare isokinetic data to existing literature, it is preferable to use the passive mode to assess peak torque or torque close to knee extension. The eccentric mode might be better to assess variables at the start of movement such as RTD.</p>","PeriodicalId":93999,"journal":{"name":"European journal of sport science","volume":"25 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11761717/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of sport science","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ejsc.12248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Some technical limitations to using the eccentric mode to measure peak eccentric strength of the hamstrings (PTHecc) were raised. PTHecc also has limited validity to predict performance or injury risk factor. Therefore, our aim was to compare PTHecc and other isokinetic variables tested in the eccentric and passive modes. Twenty male hockey players (20.2 ± 1.1 years; 179.7 ± 6.9 cm; 73.4 ± 7.1 kg and 12.2 ± 3.4% of body fat) performed maximal eccentric contractions of the hamstrings at 60°·s−1 (three repetitions) and 180°·s−1 (five repetitions) on both legs and using the eccentric mode and the passive mode (automatic movement of the lever arm) of the Biodex System 4 isokinetic dynamometer. The following variables were measured: PTHecc, the angle of peak torque (APT,°), angle-specific Hecc torque at intervals of 10° and the rate of torque development (RTD) in the first 50 ms and the first 100 ms. The main results showed that compared to the eccentric mode, the passive mode led to a significantly greater PTHecc in the non-dominant leg only and significantly smaller APT, RTD and angle-specific Hecc at angles close to knee flexion. In contrast, significantly greater angle-specific Hecc was observed in the passive mode at angles close to extension (10°–40°). This suggests that, although eccentric or concentric modes can be used to compare isokinetic data to existing literature, it is preferable to use the passive mode to assess peak torque or torque close to knee extension. The eccentric mode might be better to assess variables at the start of movement such as RTD.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信