Efficacy of SAVE: A Novel Maxillary Protraction Device-A Finite Element Analysis.

Q3 Dentistry
Sandeep Shetty, B T Nandish, Vivek Amin, Pooja Harish, Stanly S Kumar, T Abirami
{"title":"Efficacy of SAVE: A Novel Maxillary Protraction Device-A Finite Element Analysis.","authors":"Sandeep Shetty, B T Nandish, Vivek Amin, Pooja Harish, Stanly S Kumar, T Abirami","doi":"10.5005/jp-journals-10005-3003","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study describes a novel device known as \"SAVE\" to effectively protract the deficient maxilla in class III malocclusion by quantifying and evaluating the changes in the maxilla through a finite element analysis (FEA).</p><p><strong>Materials and methods: </strong>The patented novel SAVE device was three-dimensionally modeled using Autodesk Fusion 360. An existing computed tomography (CT) scan of a patient exhibiting class III malocclusion was used to generate a finite element (FE) model. The total number of nodes was 8,49,682 and 5,30,716 elements. The material of choice for the appliance was medical-grade polyetheretherketone (PEEK) polymer. The loading was performed to simulate maxillary protraction (after assigning material properties). The loading forces of 3.5, 5.5, and 9 N were simulated on each side with 30° angulations to the occlusal plane. The color changes in terms of areas of maximum (red) and minimum (blue) deformation.</p><p><strong>Results: </strong>The FEA results with protraction forces of 3.5, 5.5, and 9 N showed deformation of the maxilla in the forward and downward directions. Equivalent von Mises stress on the SAVE appliance showed stress on the superior surface of the main frame and on the area below the struts where the force module was attached. In relation to the implant, the stress concentration was on the posterior and superior area around the implant.</p><p><strong>Conclusion: </strong>The FEM analysis force vectors showed a forward and downward deformation of the maxilla with counterclockwise rotation, supporting the fact that the novel appliance could bring about effective maxillary protraction in a shorter duration.</p><p><strong>How to cite this article: </strong>Shetty S, T NB, Amin V, <i>et al</i>. Efficacy of SAVE: A Novel Maxillary Protraction Device-A Finite Element Analysis. Int J Clin Pediatr Dent 2024;17(12):1377-1382.</p>","PeriodicalId":36045,"journal":{"name":"International Journal of Clinical Pediatric Dentistry","volume":"17 12","pages":"1377-1382"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11760406/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Clinical Pediatric Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10005-3003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This study describes a novel device known as "SAVE" to effectively protract the deficient maxilla in class III malocclusion by quantifying and evaluating the changes in the maxilla through a finite element analysis (FEA).

Materials and methods: The patented novel SAVE device was three-dimensionally modeled using Autodesk Fusion 360. An existing computed tomography (CT) scan of a patient exhibiting class III malocclusion was used to generate a finite element (FE) model. The total number of nodes was 8,49,682 and 5,30,716 elements. The material of choice for the appliance was medical-grade polyetheretherketone (PEEK) polymer. The loading was performed to simulate maxillary protraction (after assigning material properties). The loading forces of 3.5, 5.5, and 9 N were simulated on each side with 30° angulations to the occlusal plane. The color changes in terms of areas of maximum (red) and minimum (blue) deformation.

Results: The FEA results with protraction forces of 3.5, 5.5, and 9 N showed deformation of the maxilla in the forward and downward directions. Equivalent von Mises stress on the SAVE appliance showed stress on the superior surface of the main frame and on the area below the struts where the force module was attached. In relation to the implant, the stress concentration was on the posterior and superior area around the implant.

Conclusion: The FEM analysis force vectors showed a forward and downward deformation of the maxilla with counterclockwise rotation, supporting the fact that the novel appliance could bring about effective maxillary protraction in a shorter duration.

How to cite this article: Shetty S, T NB, Amin V, et al. Efficacy of SAVE: A Novel Maxillary Protraction Device-A Finite Element Analysis. Int J Clin Pediatr Dent 2024;17(12):1377-1382.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
135
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信