{"title":"Hata-Yanagiya physical activity calculation system: a novel global positioning system-based method for accurate estimation of oxygen consumption during walking and running.","authors":"Keiichiro Hata, Toshio Yanagiya, Hiroaki Noro, Yoshio Suzuki","doi":"10.3389/fspor.2024.1522214","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Marathon running has become increasingly popular among amateur athletes, many of whom maintain speeds of 8-9 km/h. However, existing methods for estimating oxygen consumption (VO<sub>2</sub>) during running and walking-such as the American College of Sports Medicine (ACSM) equations and commercial activity monitors-often lack accuracy and transparency. This study introduces the Hata-Yanagiya Physical Activity Calculation (HYPAC) system, a novel approach for estimating VO<sub>2</sub> using Global Positioning System (GPS) and map data.</p><p><strong>Methods: </strong>The HYPAC system was developed through regression equations based on metabolic equivalents (METs) and slope data. To validate the system, 10 university students (5 runners, 5 non-runners) completed a 5 km course while equipped with a GPS device and a portable metabolic measurement system. VO<sub>2</sub> estimates from the HYPAC system were compared with measured values and those calculated using ACSM equations.</p><p><strong>Results: </strong>The HYPAC system demonstrated high accuracy in estimating VO<sub>2</sub>, with a relative error of -0.03 [95% confidence intervals (CI): -0.14, 0.08] compared to measured values. For the running group, the HYPAC system achieved the lowest absolute mean relative error (0.02). In the mixed running/walking group, the HYPAC system maintained strong performance with a relative error of -0.07 (95% CI: -0.26, 0.12).</p><p><strong>Discussion: </strong>The HYPAC system provides a transparent and accurate method for estimating VO<sub>2</sub> during walking and running, outperforming existing methods under varied conditions. Its open-source framework encourages further validation and improvement by researchers and practitioners. Future studies should address limitations such as sample size and population diversity to enhance the system's applicability.</p>","PeriodicalId":12716,"journal":{"name":"Frontiers in Sports and Active Living","volume":"6 ","pages":"1522214"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11757879/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Sports and Active Living","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fspor.2024.1522214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Marathon running has become increasingly popular among amateur athletes, many of whom maintain speeds of 8-9 km/h. However, existing methods for estimating oxygen consumption (VO2) during running and walking-such as the American College of Sports Medicine (ACSM) equations and commercial activity monitors-often lack accuracy and transparency. This study introduces the Hata-Yanagiya Physical Activity Calculation (HYPAC) system, a novel approach for estimating VO2 using Global Positioning System (GPS) and map data.

Methods: The HYPAC system was developed through regression equations based on metabolic equivalents (METs) and slope data. To validate the system, 10 university students (5 runners, 5 non-runners) completed a 5 km course while equipped with a GPS device and a portable metabolic measurement system. VO2 estimates from the HYPAC system were compared with measured values and those calculated using ACSM equations.

Results: The HYPAC system demonstrated high accuracy in estimating VO2, with a relative error of -0.03 [95% confidence intervals (CI): -0.14, 0.08] compared to measured values. For the running group, the HYPAC system achieved the lowest absolute mean relative error (0.02). In the mixed running/walking group, the HYPAC system maintained strong performance with a relative error of -0.07 (95% CI: -0.26, 0.12).

Discussion: The HYPAC system provides a transparent and accurate method for estimating VO2 during walking and running, outperforming existing methods under varied conditions. Its open-source framework encourages further validation and improvement by researchers and practitioners. Future studies should address limitations such as sample size and population diversity to enhance the system's applicability.

Hata-Yanagiya 体力活动计算系统:一种基于全球定位系统的新方法,用于准确估算步行和跑步时的耗氧量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.60
自引率
7.40%
发文量
459
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信