Method Development and Clinical Utility for Simultaneous Measurement of 21-Deoxycortisol, 17-Hydroxyprogesterone, Cortisol, and Cortisone Levels in Human Plasma Using UHPLC-MS/MS.

IF 2.1 Q3 PHARMACOLOGY & PHARMACY
Advances in Pharmacological and Pharmaceutical Sciences Pub Date : 2025-01-17 eCollection Date: 2025-01-01 DOI:10.1155/adpp/3859670
Syed N Alvi, Saleh Al Dgither, Ali Al-Odaib
{"title":"Method Development and Clinical Utility for Simultaneous Measurement of 21-Deoxycortisol, 17-Hydroxyprogesterone, Cortisol, and Cortisone Levels in Human Plasma Using UHPLC-MS/MS.","authors":"Syed N Alvi, Saleh Al Dgither, Ali Al-Odaib","doi":"10.1155/adpp/3859670","DOIUrl":null,"url":null,"abstract":"<p><p>A simple and efficient validated assay for quantifying 21-deoxycortisol (21-DOC), 17-hydroxyprogesterone (17-OHP), cortisol, and cortisone in human plasma has been developed using ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). Analysis of plasma samples were performed on Atlantis dC18 (3 <i>μ</i>m) column using a mobile phase of 20.0 mM ammonium acetate and acetonitrile (50:50, <i>v</i> : <i>v</i>) that was delivered at isocratic flow rate 0.3 mL/minute. After addition of d4-cortisol as an internal standard (IS), plasma samples containing 21-DOC, 17-OHP, cortisol, and cortisone were extracted with mixture of dichloromethane and tert-butylmethyl ether 1:2 (<i>v</i>/<i>v</i>). Analytes were detected and quantified in the positive ion mode of electrospray ionization using multiple reaction monitoring transition set at mass to charge (m/z): 347.17 ⟶ 311.12, 331.17 ⟶ 96.97, 363.11 ⟶ 121.00, 361.18 ⟶ 163.11, and 367.19 ⟶ 121.24 for 21-DOC and 17-OHP, cortisol, cortisone, and cortisol-d4 (IS), respectively. The relationship between concentration and peak area response (analyte/IS) were linear over the range of 0.25-50, 0.5-100, 1-200, and 2-400 ng/mL for 21-DOC, 17-OHP, cortisone, and cortisol, respectively. The mean extraction recovery of the analytes was in the range of 83%-96%. The coefficient of variation within and between days was less than 13.6%, and the bias ranged from -9.2% to 12%. The measured level of cortisol, cortisone, and 17-OHP was in the range of 21.9-110, 4.33-12.71, and 0.37-1.4 ng/mL, respectively. Furthermore, the measured value of cortisone-cortisol ratio was in the range of 0.08-0.21.</p>","PeriodicalId":7369,"journal":{"name":"Advances in Pharmacological and Pharmaceutical Sciences","volume":"2025 ","pages":"3859670"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11759567/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Pharmacological and Pharmaceutical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/adpp/3859670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

A simple and efficient validated assay for quantifying 21-deoxycortisol (21-DOC), 17-hydroxyprogesterone (17-OHP), cortisol, and cortisone in human plasma has been developed using ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). Analysis of plasma samples were performed on Atlantis dC18 (3 μm) column using a mobile phase of 20.0 mM ammonium acetate and acetonitrile (50:50, v : v) that was delivered at isocratic flow rate 0.3 mL/minute. After addition of d4-cortisol as an internal standard (IS), plasma samples containing 21-DOC, 17-OHP, cortisol, and cortisone were extracted with mixture of dichloromethane and tert-butylmethyl ether 1:2 (v/v). Analytes were detected and quantified in the positive ion mode of electrospray ionization using multiple reaction monitoring transition set at mass to charge (m/z): 347.17 ⟶ 311.12, 331.17 ⟶ 96.97, 363.11 ⟶ 121.00, 361.18 ⟶ 163.11, and 367.19 ⟶ 121.24 for 21-DOC and 17-OHP, cortisol, cortisone, and cortisol-d4 (IS), respectively. The relationship between concentration and peak area response (analyte/IS) were linear over the range of 0.25-50, 0.5-100, 1-200, and 2-400 ng/mL for 21-DOC, 17-OHP, cortisone, and cortisol, respectively. The mean extraction recovery of the analytes was in the range of 83%-96%. The coefficient of variation within and between days was less than 13.6%, and the bias ranged from -9.2% to 12%. The measured level of cortisol, cortisone, and 17-OHP was in the range of 21.9-110, 4.33-12.71, and 0.37-1.4 ng/mL, respectively. Furthermore, the measured value of cortisone-cortisol ratio was in the range of 0.08-0.21.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
3.60%
发文量
0
审稿时长
17 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信