A Method to Evaluate Orientation-Dependent Errors in the Center of Contrast Targets Used with Terrestrial Laser Scanners.

IF 3.4 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL
Sensors Pub Date : 2025-01-16 DOI:10.3390/s25020505
Bala Muralikrishnan, Xinsu Lu, Mary Gregg, Meghan Shilling, Braden Czapla
{"title":"A Method to Evaluate Orientation-Dependent Errors in the Center of Contrast Targets Used with Terrestrial Laser Scanners.","authors":"Bala Muralikrishnan, Xinsu Lu, Mary Gregg, Meghan Shilling, Braden Czapla","doi":"10.3390/s25020505","DOIUrl":null,"url":null,"abstract":"<p><p>Terrestrial laser scanners (TLS) are portable dimensional measurement instruments used to obtain 3D point clouds of objects in a scene. While TLSs do not require the use of cooperative targets, they are sometimes placed in a scene to fuse or compare data from different instruments or data from the same instrument but from different positions. A contrast target is an example of such a target; it consists of alternating black/white squares that can be printed using a laser printer. Because contrast targets are planar as opposed to three-dimensional (like a sphere), the center of the target might suffer from errors that depend on the orientation of the target with respect to the TLS. In this paper, we discuss a low-cost method to characterize such errors and present results obtained from a short-range TLS and a long-range TLS. Our method involves comparing the center of a contrast target against the center of spheres and, therefore, does not require the use of a reference instrument or calibrated objects. For the short-range TLS, systematic errors of up to 0.5 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) and resolutions (30 points-per-degree (ppd) and 90 ppd) considered for this TLS. For the long-range TLS, systematic errors of about 0.3 mm to 0.8 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) at low resolution (28 ppd). Errors of under 0.3 mm were observed in the target center as a function of the angle for the two distances at high resolution (109 ppd).</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"25 2","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11768863/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s25020505","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Terrestrial laser scanners (TLS) are portable dimensional measurement instruments used to obtain 3D point clouds of objects in a scene. While TLSs do not require the use of cooperative targets, they are sometimes placed in a scene to fuse or compare data from different instruments or data from the same instrument but from different positions. A contrast target is an example of such a target; it consists of alternating black/white squares that can be printed using a laser printer. Because contrast targets are planar as opposed to three-dimensional (like a sphere), the center of the target might suffer from errors that depend on the orientation of the target with respect to the TLS. In this paper, we discuss a low-cost method to characterize such errors and present results obtained from a short-range TLS and a long-range TLS. Our method involves comparing the center of a contrast target against the center of spheres and, therefore, does not require the use of a reference instrument or calibrated objects. For the short-range TLS, systematic errors of up to 0.5 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) and resolutions (30 points-per-degree (ppd) and 90 ppd) considered for this TLS. For the long-range TLS, systematic errors of about 0.3 mm to 0.8 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) at low resolution (28 ppd). Errors of under 0.3 mm were observed in the target center as a function of the angle for the two distances at high resolution (109 ppd).

求助全文
约1分钟内获得全文 求助全文
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信