Laser Welding of Micro-Wire Stent Electrode as a Minimally Invasive Endovascular Neural Interface.

IF 3 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL
Micromachines Pub Date : 2024-12-26 DOI:10.3390/mi16010021
Bo Wen, Liang Shen, Xiaoyang Kang
{"title":"Laser Welding of Micro-Wire Stent Electrode as a Minimally Invasive Endovascular Neural Interface.","authors":"Bo Wen, Liang Shen, Xiaoyang Kang","doi":"10.3390/mi16010021","DOIUrl":null,"url":null,"abstract":"<p><p>Minimally invasive endovascular stent electrodes are an emerging technology in neural engineering, designed to minimize the damage to neural tissue. However, conventional stent electrodes often rely on resistive welding and are relatively bulky, restricting their use primarily to large animals or thick blood vessels. In this study, the feasibility is explored of fabricating a laser welding stent electrode as small as 300 μm. A high-precision laser welding technique was developed to join micro-wire electrodes without compromising structural integrity or performance. To ensure consistent results, a novel micro-wire welding with platinum pad method was introduced during the welding process. The fabricated electrodes were integrated with stent structures and subjected to detailed electrochemical performance testing to evaluate their potential as neural interface components. The laser-welded endovascular stent electrodes exhibited excellent electrochemical properties, including low impedance and stable charge transfer capabilities. At the same time, in this study, a simulation is conducted of the electrode distribution and arrangement on the stent structure, optimizing the utilization of the available surface area for enhanced functionality. These results demonstrate the potential of the fabricated electrodes for high-performance neural interfacing in endovascular applications. The approach provided a promising solution for advancing endovascular neural engineering technologies, particularly in applications requiring compact electrode designs.</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"16 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11767702/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi16010021","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Minimally invasive endovascular stent electrodes are an emerging technology in neural engineering, designed to minimize the damage to neural tissue. However, conventional stent electrodes often rely on resistive welding and are relatively bulky, restricting their use primarily to large animals or thick blood vessels. In this study, the feasibility is explored of fabricating a laser welding stent electrode as small as 300 μm. A high-precision laser welding technique was developed to join micro-wire electrodes without compromising structural integrity or performance. To ensure consistent results, a novel micro-wire welding with platinum pad method was introduced during the welding process. The fabricated electrodes were integrated with stent structures and subjected to detailed electrochemical performance testing to evaluate their potential as neural interface components. The laser-welded endovascular stent electrodes exhibited excellent electrochemical properties, including low impedance and stable charge transfer capabilities. At the same time, in this study, a simulation is conducted of the electrode distribution and arrangement on the stent structure, optimizing the utilization of the available surface area for enhanced functionality. These results demonstrate the potential of the fabricated electrodes for high-performance neural interfacing in endovascular applications. The approach provided a promising solution for advancing endovascular neural engineering technologies, particularly in applications requiring compact electrode designs.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Micromachines
Micromachines NANOSCIENCE & NANOTECHNOLOGY-INSTRUMENTS & INSTRUMENTATION
CiteScore
5.20
自引率
14.70%
发文量
1862
审稿时长
16.31 days
期刊介绍: Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信