{"title":"Impact of Cell Layout on Bandwidth of Multi-Frequency Piezoelectric Micromachined Ultrasonic Transducer Array.","authors":"Wanli Yang, Huimin Li, Yuewu Gong, Zhuochen Wang, Xingli Xu, Xiaofan Hu, Pengfei Niu, Wei Pang","doi":"10.3390/mi16010049","DOIUrl":null,"url":null,"abstract":"<p><p>Piezoelectric micromachined ultrasonic transducers (PMUTs) show considerable promise for application in ultrasound imaging, but the limited bandwidth of the traditional PMUTs largely affects the imaging quality. This paper focuses on how to arrange cells with different frequencies to maximize the bandwidth and proposes a multi-frequency PMUT (MF-PMUT) linear array. Seven cells with gradually changing frequencies are arranged in a monotonic trend to form a unit, and 32 units are distributed across four lines, forming one element. To investigate how the arrangement of cells affects the bandwidth, three different arrays were designed according to the extent of unit aggregation from the same frequency. Underwater experiments were conducted to assess the acoustic performance, especially the bandwidth. We found that the densest arrangement of the same cells produced the largest bandwidth, achieving a 92% transmission bandwidth and a 50% burst-echo bandwidth at 6 MHz. The mechanism was investigated from the coupling point of view by finite element analysis and laser Doppler vibrometry, focusing on the cell displacements. The results demonstrated strong ultrasound coupling in the devices, resulting in larger bandwidths. To exploit the advanced bandwidth but reduce the crosstalk, grooves for isolation were fabricated between elements. This work proposes an effective strategy for developing advanced PMUT arrays that would benefit ultrasound imaging applications.</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"16 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11767585/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi16010049","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Piezoelectric micromachined ultrasonic transducers (PMUTs) show considerable promise for application in ultrasound imaging, but the limited bandwidth of the traditional PMUTs largely affects the imaging quality. This paper focuses on how to arrange cells with different frequencies to maximize the bandwidth and proposes a multi-frequency PMUT (MF-PMUT) linear array. Seven cells with gradually changing frequencies are arranged in a monotonic trend to form a unit, and 32 units are distributed across four lines, forming one element. To investigate how the arrangement of cells affects the bandwidth, three different arrays were designed according to the extent of unit aggregation from the same frequency. Underwater experiments were conducted to assess the acoustic performance, especially the bandwidth. We found that the densest arrangement of the same cells produced the largest bandwidth, achieving a 92% transmission bandwidth and a 50% burst-echo bandwidth at 6 MHz. The mechanism was investigated from the coupling point of view by finite element analysis and laser Doppler vibrometry, focusing on the cell displacements. The results demonstrated strong ultrasound coupling in the devices, resulting in larger bandwidths. To exploit the advanced bandwidth but reduce the crosstalk, grooves for isolation were fabricated between elements. This work proposes an effective strategy for developing advanced PMUT arrays that would benefit ultrasound imaging applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Micromachines
Micromachines NANOSCIENCE & NANOTECHNOLOGY-INSTRUMENTS & INSTRUMENTATION
CiteScore
5.20
自引率
14.70%
发文量
1862
审稿时长
16.31 days
期刊介绍: Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信