Non-invasive assessment of intracranial compliance in idiopathic intracranial hypertension: an MRI-ICP study.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Eye Pub Date : 2025-01-24 DOI:10.1038/s41433-024-03547-7
Matilde Sassani, James L Mitchell, Andreas Yiangou, Nigel Davies, Vijay Sawlani, Susan P Mollan, Mark E Wagshul, Alexandra J Sinclair
{"title":"Non-invasive assessment of intracranial compliance in idiopathic intracranial hypertension: an MRI-ICP study.","authors":"Matilde Sassani, James L Mitchell, Andreas Yiangou, Nigel Davies, Vijay Sawlani, Susan P Mollan, Mark E Wagshul, Alexandra J Sinclair","doi":"10.1038/s41433-024-03547-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>Idiopathic intracranial hypertension (IIH) is a disease which threatens vision and causes disabling headaches, affecting women of childbearing age with obesity. It is characterised by raised intracranial pressure (ICP), measured invasively either with lumbar punctures or intracranially-inserted monitors. There is an unmet clinical need to develop non-invasive means to assess ICP. This study aims to utilise the MRI-ICP imaging technique to measure intracranial compliance index and assess its suitability as surrogate biomarker of ICP.</p><p><strong>Subjects/methods: </strong>Nine IIH patients and ten age, sex, and body mass index matched healthy controls were recruited. All participants underwent lumbar puncture, visual assessments, detailed headache phenotyping, and MRI-ICP scans to calculate intracranial compliance index at baseline. Following treatment, patients were invited to attend a one-year visit when all assessments were repeated.</p><p><strong>Results: </strong>There was significant (p = 0.017) reduction in intracranial compliance index in IIH (mean = 1006.0 cc/mmHg/cm, SD = ± 384.6 cc/mmHg/cm) compared to controls (mean = 1493.0 cc/mmHg/cm, SD = ± 411.8 cc/mmHg/cm), inversely correlating with lumbar puncture opening pressure (r = -0.502, p = 0.029). A significant inverse correlation between compliance index and headache disability was also found (r = -0.458, p = 0.049) and a trend for an association between lower compliance index and increased frequency of headaches (r = -0.430, p = 0.066). This latter became significant (p = 0.018) after accounting for use of analgesics. Following successful treatment, compliance index was increased in all patients at one year (mean of differences = 380.7 cc/mmHg/cm, p = 0.031).</p><p><strong>Conclusions: </strong>This is the first study to apply the MRI-ICP technique longitudinally in IIH. It illustrates reduced intracranial compliance index in IIH, correlating with opening pressure and headache disability and ameliorating with treatment.</p>","PeriodicalId":12125,"journal":{"name":"Eye","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41433-024-03547-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/objectives: Idiopathic intracranial hypertension (IIH) is a disease which threatens vision and causes disabling headaches, affecting women of childbearing age with obesity. It is characterised by raised intracranial pressure (ICP), measured invasively either with lumbar punctures or intracranially-inserted monitors. There is an unmet clinical need to develop non-invasive means to assess ICP. This study aims to utilise the MRI-ICP imaging technique to measure intracranial compliance index and assess its suitability as surrogate biomarker of ICP.

Subjects/methods: Nine IIH patients and ten age, sex, and body mass index matched healthy controls were recruited. All participants underwent lumbar puncture, visual assessments, detailed headache phenotyping, and MRI-ICP scans to calculate intracranial compliance index at baseline. Following treatment, patients were invited to attend a one-year visit when all assessments were repeated.

Results: There was significant (p = 0.017) reduction in intracranial compliance index in IIH (mean = 1006.0 cc/mmHg/cm, SD = ± 384.6 cc/mmHg/cm) compared to controls (mean = 1493.0 cc/mmHg/cm, SD = ± 411.8 cc/mmHg/cm), inversely correlating with lumbar puncture opening pressure (r = -0.502, p = 0.029). A significant inverse correlation between compliance index and headache disability was also found (r = -0.458, p = 0.049) and a trend for an association between lower compliance index and increased frequency of headaches (r = -0.430, p = 0.066). This latter became significant (p = 0.018) after accounting for use of analgesics. Following successful treatment, compliance index was increased in all patients at one year (mean of differences = 380.7 cc/mmHg/cm, p = 0.031).

Conclusions: This is the first study to apply the MRI-ICP technique longitudinally in IIH. It illustrates reduced intracranial compliance index in IIH, correlating with opening pressure and headache disability and ameliorating with treatment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Eye
Eye 医学-眼科学
CiteScore
6.40
自引率
5.10%
发文量
481
审稿时长
3-6 weeks
期刊介绍: Eye seeks to provide the international practising ophthalmologist with high quality articles, of academic rigour, on the latest global clinical and laboratory based research. Its core aim is to advance the science and practice of ophthalmology with the latest clinical- and scientific-based research. Whilst principally aimed at the practising clinician, the journal contains material of interest to a wider readership including optometrists, orthoptists, other health care professionals and research workers in all aspects of the field of visual science worldwide. Eye is the official journal of The Royal College of Ophthalmologists. Eye encourages the submission of original articles covering all aspects of ophthalmology including: external eye disease; oculo-plastic surgery; orbital and lacrimal disease; ocular surface and corneal disorders; paediatric ophthalmology and strabismus; glaucoma; medical and surgical retina; neuro-ophthalmology; cataract and refractive surgery; ocular oncology; ophthalmic pathology; ophthalmic genetics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信