Accurate urine sodium measurements at home using Point of Care Testing in patients with Short Bowel Syndrome.

IF 2.9 Q3 NUTRITION & DIETETICS
Miranda Van Berkel, Judith Beurskens-Meijerink, Nicole Buters-Ambrosius, Eline Van Der Hagen, Getty Huisman-De Waal, Geert Wanten
{"title":"Accurate urine sodium measurements at home using Point of Care Testing in patients with Short Bowel Syndrome.","authors":"Miranda Van Berkel, Judith Beurskens-Meijerink, Nicole Buters-Ambrosius, Eline Van Der Hagen, Getty Huisman-De Waal, Geert Wanten","doi":"10.1016/j.clnesp.2025.01.040","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Measurement of the urine sodium concentration (USC) is a simple procedure that in many patients adequately indicates their hydration status. This is of particular importance in patients suffering from short bowel syndrome (SBS), who may very rapidly dehydrate and are at risk for permanently compromising their kidney function. A point of care test (POCT) that allows reliable measurement of USC would enable these patients to effectively evaluate their sodium- and water balance in the at home setting, thereby avoiding hospital visits and delayed test results. In this study, a POCT device to assess USC was first analytically validated after which it was applied for the at home evaluation of the hydration status in patients with SBS.</p><p><strong>Methods: </strong>First, we validated the imprecision, bias and limit of quantification of USC as measured with the Fisic Medimate POCT device in comparison to an automated routine chemistry system. Next, the device was used for monitoring USC at home in 21 patients with SBS, including an evaluation of user friendliness System Usability Scale (SUS) and accuracy for detecting low sodium levels as compared to the routine chemistry system.</p><p><strong>Results: </strong>The imprecision of the POCT device at low USC was 6.1 %. In samples at the clinical decision threshold to identify patients at the verge of dehydration of 20 mmol/l as measured by routine chemistry USC, the POCT device demonstrated a mean estimation of USC of 20.6 mmol/l (95% CI 18.8-22.4). Dehydration was detected with a sensitivity of 95% when the medical decision limit for urinary sodium on the POCT device was set at a safe concentration of 30 mmol/l. Using the device was straightforward and easy to learn for patients with an overall System Usability Scale (SUS) score of 86.</p><p><strong>Conclusion: </strong>USC measurements using this POCT device can be safely integrated into daily practice for early detection of dehydration in patients with SBS. Clear patient instructions to ensure accurate drop dispensing and a higher clinical decision threshold of USC of 30 mmol/l will allow a high sensitivity for detecting dehydration in patients with short bowel syndrome.</p>","PeriodicalId":10352,"journal":{"name":"Clinical nutrition ESPEN","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical nutrition ESPEN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.clnesp.2025.01.040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: Measurement of the urine sodium concentration (USC) is a simple procedure that in many patients adequately indicates their hydration status. This is of particular importance in patients suffering from short bowel syndrome (SBS), who may very rapidly dehydrate and are at risk for permanently compromising their kidney function. A point of care test (POCT) that allows reliable measurement of USC would enable these patients to effectively evaluate their sodium- and water balance in the at home setting, thereby avoiding hospital visits and delayed test results. In this study, a POCT device to assess USC was first analytically validated after which it was applied for the at home evaluation of the hydration status in patients with SBS.

Methods: First, we validated the imprecision, bias and limit of quantification of USC as measured with the Fisic Medimate POCT device in comparison to an automated routine chemistry system. Next, the device was used for monitoring USC at home in 21 patients with SBS, including an evaluation of user friendliness System Usability Scale (SUS) and accuracy for detecting low sodium levels as compared to the routine chemistry system.

Results: The imprecision of the POCT device at low USC was 6.1 %. In samples at the clinical decision threshold to identify patients at the verge of dehydration of 20 mmol/l as measured by routine chemistry USC, the POCT device demonstrated a mean estimation of USC of 20.6 mmol/l (95% CI 18.8-22.4). Dehydration was detected with a sensitivity of 95% when the medical decision limit for urinary sodium on the POCT device was set at a safe concentration of 30 mmol/l. Using the device was straightforward and easy to learn for patients with an overall System Usability Scale (SUS) score of 86.

Conclusion: USC measurements using this POCT device can be safely integrated into daily practice for early detection of dehydration in patients with SBS. Clear patient instructions to ensure accurate drop dispensing and a higher clinical decision threshold of USC of 30 mmol/l will allow a high sensitivity for detecting dehydration in patients with short bowel syndrome.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical nutrition ESPEN
Clinical nutrition ESPEN NUTRITION & DIETETICS-
CiteScore
4.90
自引率
3.30%
发文量
512
期刊介绍: Clinical Nutrition ESPEN is an electronic-only journal and is an official publication of the European Society for Clinical Nutrition and Metabolism (ESPEN). Nutrition and nutritional care have gained wide clinical and scientific interest during the past decades. The increasing knowledge of metabolic disturbances and nutritional assessment in chronic and acute diseases has stimulated rapid advances in design, development and clinical application of nutritional support. The aims of ESPEN are to encourage the rapid diffusion of knowledge and its application in the field of clinical nutrition and metabolism. Published bimonthly, Clinical Nutrition ESPEN focuses on publishing articles on the relationship between nutrition and disease in the setting of basic science and clinical practice. Clinical Nutrition ESPEN is available to all members of ESPEN and to all subscribers of Clinical Nutrition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信