Fetal Safety in MRI During Pregnancy: A Comprehensive Review.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Gal Puris, Angela Chetrit, Eldad Katorza
{"title":"Fetal Safety in MRI During Pregnancy: A Comprehensive Review.","authors":"Gal Puris, Angela Chetrit, Eldad Katorza","doi":"10.3390/diagnostics15020208","DOIUrl":null,"url":null,"abstract":"<p><p>As medical imaging continues to expand, concerns about the potential risks of ionizing radiation to the developing fetus have led to a preference for non-radiation-based alternatives such as ultrasonography and fetal MRI. This review examines the current evidence on the safety of MRI during pregnancy, with a focus on 3 T MRI and contrast agents, aiming to provide a comprehensive synthesis that informs clinical decision-making, ensures fetal safety and supports the safe use of all available modalities that could impact management. We conducted a comprehensive review of studies from 2000 to 2024 on MRI safety during pregnancy, focusing on 3 T MRI and gadolinium use. The review included peer-reviewed articles and large database studies, summarizing key findings and identifying areas for further research. Fetal MRI, used alongside ultrasound, enhances diagnostic accuracy for fetal anomalies, particularly in the brain, thorax, gastrointestinal and genitourinary systems, with no conclusive evidence of adverse effects on fetal development. While theoretical risks such as tissue heating and acoustic damage exist, studies show no significant harm at 1.5 T or 3 T, though caution is still advised in the first trimester. Regarding gadolinium-based contrast agents, the evidence is conflicting: while some studies suggest risks such as stillbirth and rheumatological conditions, animal studies show minimal fetal retention and no significant toxicity, and later clinical research has not substantiated these risks. The existing literature on fetal MRI is encouraging, suggesting minimal risks; however, further investigation through larger, prospective and long-term follow-up studies is essential to comprehensively determine its safety and late effects.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 2","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11765095/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15020208","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

As medical imaging continues to expand, concerns about the potential risks of ionizing radiation to the developing fetus have led to a preference for non-radiation-based alternatives such as ultrasonography and fetal MRI. This review examines the current evidence on the safety of MRI during pregnancy, with a focus on 3 T MRI and contrast agents, aiming to provide a comprehensive synthesis that informs clinical decision-making, ensures fetal safety and supports the safe use of all available modalities that could impact management. We conducted a comprehensive review of studies from 2000 to 2024 on MRI safety during pregnancy, focusing on 3 T MRI and gadolinium use. The review included peer-reviewed articles and large database studies, summarizing key findings and identifying areas for further research. Fetal MRI, used alongside ultrasound, enhances diagnostic accuracy for fetal anomalies, particularly in the brain, thorax, gastrointestinal and genitourinary systems, with no conclusive evidence of adverse effects on fetal development. While theoretical risks such as tissue heating and acoustic damage exist, studies show no significant harm at 1.5 T or 3 T, though caution is still advised in the first trimester. Regarding gadolinium-based contrast agents, the evidence is conflicting: while some studies suggest risks such as stillbirth and rheumatological conditions, animal studies show minimal fetal retention and no significant toxicity, and later clinical research has not substantiated these risks. The existing literature on fetal MRI is encouraging, suggesting minimal risks; however, further investigation through larger, prospective and long-term follow-up studies is essential to comprehensively determine its safety and late effects.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信