Feasibility of YOLOX computer model-based assessment of knee function compared with manual assessment for people with severe knee osteoarthritis.

IF 3.3 3区 医学 Q2 MEDICAL INFORMATICS
Tao Yang, Jie Zhao, Ben Wang, Li Wang, Hengzhe Bao, Bing Li, Wen Luo, Huiwen Zhao, Jun Liu
{"title":"Feasibility of YOLOX computer model-based assessment of knee function compared with manual assessment for people with severe knee osteoarthritis.","authors":"Tao Yang, Jie Zhao, Ben Wang, Li Wang, Hengzhe Bao, Bing Li, Wen Luo, Huiwen Zhao, Jun Liu","doi":"10.1186/s12911-025-02877-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to assess the feasibility of computer model-based evaluation of knee joint functional capacity in comparison with manual assessment.</p><p><strong>Methods: </strong>This study consisted of two phases: (1) developing an automatic knee joint action recognition and classification system on the basis of improved YOLOX and (2) analyzing the feasibility of assessment by the software system and doctors, identifying the knee joint function of patients, and determining the accuracy of the software system. We collected 40-50 samples for use in clinical experiments. The datasets used in this study were collected from patients admitted to the Joint Surgery Center. In this study, the knee joint assessment items included stair climbing, walking on uneven surfaces, and knee joint function. To assess the computer model's automatic evaluation of knee joint function, MedCalc 20 statistical software was used to analyze the consistency of the Lequesne functional index between the computer model's automated determinations and manual independent assessments.</p><p><strong>Results: </strong>The weighted kappa coefficients between the doctors' assessments and the software system's assessments were 0.76 (95% confidence intervals:0.59 ~ 0.92) for climbing up and down stairs, 0.64 (95% confidence intervals:0.45 ~ 0.82) for walking on uneven floors, and 0.68 (95% confidence intervals:0.53 ~ 0.84) for the Lequesne functional index, indicating good consistency between the assessments of the software system and doctors.</p><p><strong>Conclusion: </strong>This paper introduces an automatic knee joint action recognition and classification method based on improved YOLOX. By comparing the results obtained by orthopedic doctors and the software system, the feasibility of this software system was validated in the clinic.</p>","PeriodicalId":9340,"journal":{"name":"BMC Medical Informatics and Decision Making","volume":"25 1","pages":"40"},"PeriodicalIF":3.3000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11763141/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Informatics and Decision Making","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12911-025-02877-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL INFORMATICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to assess the feasibility of computer model-based evaluation of knee joint functional capacity in comparison with manual assessment.

Methods: This study consisted of two phases: (1) developing an automatic knee joint action recognition and classification system on the basis of improved YOLOX and (2) analyzing the feasibility of assessment by the software system and doctors, identifying the knee joint function of patients, and determining the accuracy of the software system. We collected 40-50 samples for use in clinical experiments. The datasets used in this study were collected from patients admitted to the Joint Surgery Center. In this study, the knee joint assessment items included stair climbing, walking on uneven surfaces, and knee joint function. To assess the computer model's automatic evaluation of knee joint function, MedCalc 20 statistical software was used to analyze the consistency of the Lequesne functional index between the computer model's automated determinations and manual independent assessments.

Results: The weighted kappa coefficients between the doctors' assessments and the software system's assessments were 0.76 (95% confidence intervals:0.59 ~ 0.92) for climbing up and down stairs, 0.64 (95% confidence intervals:0.45 ~ 0.82) for walking on uneven floors, and 0.68 (95% confidence intervals:0.53 ~ 0.84) for the Lequesne functional index, indicating good consistency between the assessments of the software system and doctors.

Conclusion: This paper introduces an automatic knee joint action recognition and classification method based on improved YOLOX. By comparing the results obtained by orthopedic doctors and the software system, the feasibility of this software system was validated in the clinic.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
5.70%
发文量
297
审稿时长
1 months
期刊介绍: BMC Medical Informatics and Decision Making is an open access journal publishing original peer-reviewed research articles in relation to the design, development, implementation, use, and evaluation of health information technologies and decision-making for human health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信