Different manipulations for resolving the overlapped spectra of novel anti-asthmatic combination: Green-blue-white triple evaluation tools

IF 2.6 4区 生物学 Q2 BIOCHEMICAL RESEARCH METHODS
Michael Gamal Fawzy , Hawa Khalil , Alaa Reda , Eman A. Bahgat
{"title":"Different manipulations for resolving the overlapped spectra of novel anti-asthmatic combination: Green-blue-white triple evaluation tools","authors":"Michael Gamal Fawzy ,&nbsp;Hawa Khalil ,&nbsp;Alaa Reda ,&nbsp;Eman A. Bahgat","doi":"10.1016/j.ab.2025.115783","DOIUrl":null,"url":null,"abstract":"<div><div>This work represents different spectrophotometric techniques for concurrent quantification of Indacaterol (IND) and Mometasone furoate (MOM); co-formulated inhalation capsules to control asthma symptoms. Direct spectrophotometric (D<sup>0</sup>) approach was applied for IND assay. While, absorption factor (AF), ratio difference (RD), mean centering of the ratio spectra (MC), and continuous wavelet transform (CW) techniques were utilized for MOM quantification. The applied methods' validation was accomplished relative to the ICH guidelines. Within the linearity range of (4–20 μg/mL), these approaches provided accurate and precise assessment of IND and MOM in laboratory-synthetic mixtures and pharmaceutical formulation with determination coefficients higher than 0.9997. Moreover, the proposed methods demonstrated good detection and quantification levels. The respective LOD and LOQ for IND were (0.33 μg/mL) and (1.01 μg/mL). While, the LOD and LOQ for MOM were ranging from (0.16–0.30 μg/mL) and (0.47–0.91 μg/mL), respectively. Statistical comparison revealed no significant differences between the findings derived from the proposed methods and the reported one. The applied methods’ environmental effect was cheeked using Analytical Greenness Calculator (AGREE), Blue Applicability Grade Index (BAGI), and Red-Green-Blue 12 (RGB12). All the utilized metrics showed reliable scores, approving that the proposed methods were adhered to the sustainability principles.</div></div>","PeriodicalId":7830,"journal":{"name":"Analytical biochemistry","volume":"700 ","pages":"Article 115783"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical biochemistry","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S000326972500020X","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

This work represents different spectrophotometric techniques for concurrent quantification of Indacaterol (IND) and Mometasone furoate (MOM); co-formulated inhalation capsules to control asthma symptoms. Direct spectrophotometric (D0) approach was applied for IND assay. While, absorption factor (AF), ratio difference (RD), mean centering of the ratio spectra (MC), and continuous wavelet transform (CW) techniques were utilized for MOM quantification. The applied methods' validation was accomplished relative to the ICH guidelines. Within the linearity range of (4–20 μg/mL), these approaches provided accurate and precise assessment of IND and MOM in laboratory-synthetic mixtures and pharmaceutical formulation with determination coefficients higher than 0.9997. Moreover, the proposed methods demonstrated good detection and quantification levels. The respective LOD and LOQ for IND were (0.33 μg/mL) and (1.01 μg/mL). While, the LOD and LOQ for MOM were ranging from (0.16–0.30 μg/mL) and (0.47–0.91 μg/mL), respectively. Statistical comparison revealed no significant differences between the findings derived from the proposed methods and the reported one. The applied methods’ environmental effect was cheeked using Analytical Greenness Calculator (AGREE), Blue Applicability Grade Index (BAGI), and Red-Green-Blue 12 (RGB12). All the utilized metrics showed reliable scores, approving that the proposed methods were adhered to the sustainability principles.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical biochemistry
Analytical biochemistry 生物-分析化学
CiteScore
5.70
自引率
0.00%
发文量
283
审稿时长
44 days
期刊介绍: The journal''s title Analytical Biochemistry: Methods in the Biological Sciences declares its broad scope: methods for the basic biological sciences that include biochemistry, molecular genetics, cell biology, proteomics, immunology, bioinformatics and wherever the frontiers of research take the field. The emphasis is on methods from the strictly analytical to the more preparative that would include novel approaches to protein purification as well as improvements in cell and organ culture. The actual techniques are equally inclusive ranging from aptamers to zymology. The journal has been particularly active in: -Analytical techniques for biological molecules- Aptamer selection and utilization- Biosensors- Chromatography- Cloning, sequencing and mutagenesis- Electrochemical methods- Electrophoresis- Enzyme characterization methods- Immunological approaches- Mass spectrometry of proteins and nucleic acids- Metabolomics- Nano level techniques- Optical spectroscopy in all its forms. The journal is reluctant to include most drug and strictly clinical studies as there are more suitable publication platforms for these types of papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信