{"title":"Preparation of CHS-Fe<sub>3</sub>O<sub>4</sub>@@ZIF-8 peroxidase-mimic with an ultra-thin hollow layer for ultrasensitive electrochemical detection of kanamycin.","authors":"Jiadong Zhang, Yaoying Cui, Yanchao Dou, Jingying Zhu, Xiangyu Ma, Liming Guo, Kai Zhang, Nan Hao, Liangdong Feng, Yi Chen","doi":"10.1007/s00604-025-06965-w","DOIUrl":null,"url":null,"abstract":"<p><p>A highly sensitive and selective electrochemical biosensor was developed for the detection of kanamycin using a core-hollow-shell structured peroxidase-mimic nanozyme, CHS-Fe₃O₄@@ZIF-8. The synthesized CHS-Fe<sub>3</sub>O<sub>4</sub>@@ZIF-8 was characterized with scanning electron microscopy, transmission electron microscopy, and X-ray photoelectron spectroscopy. It was found that the CHS-Fe<sub>3</sub>O<sub>4</sub>@@ZIF-8 exhibits excellent peroxidase-like activity due to  its ultra-thin hollow layer. Besides, CHS-Fe<sub>3</sub>O<sub>4</sub>@@ZIF-8 functionalized with complementary chains of kanamycin aptamer was anchored to the electrode surface via complementary base pairing with the kanamycin aptamer. Upon the presence of kanamycin, a strand displacement reaction was triggered leading to a reduction in the number of the CHS-Fe<sub>3</sub>O<sub>4</sub>@@ZIF-8, which slowed down the catalytic reaction of the substrate 3,3',5,5' -tetramethylbenzidine (TMB) facilitated by CHS-Fe<sub>3</sub>O<sub>4</sub>@@ZIF 8. Differential pulse voltammetry (DPV) was employed to measure and record changes in peak current resulting from catalytic oxidation product formation (oxidation product of TMB). The electrochemical signal exhibited a linear relationship with logarithmic variations in kanamycin concentration within a range spanning from 10 to 8000 pM and achieved an impressive detection limit as low as 7.52 pM. Furthermore, successful detection of kanamycin content in serum samples using this sensor demonstrated its good specificity and reproducibility. These findings indicate that the constructed electrochemical kanamycin sensor holds significant potential for practical applications. The biosensor demonstrated high selectivity, distinguishing kanamycin from other antibiotics, and exhibited good reproducibility, making it reliable for practical applications. The successful detection of kanamycin in serum samples further underscores the sensor's potential for real-world applications, particularly in monitoring antibiotic residues in food products and clinical diagnostics.</p>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 2","pages":"106"},"PeriodicalIF":5.3000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00604-025-06965-w","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A highly sensitive and selective electrochemical biosensor was developed for the detection of kanamycin using a core-hollow-shell structured peroxidase-mimic nanozyme, CHS-Fe₃O₄@@ZIF-8. The synthesized CHS-Fe3O4@@ZIF-8 was characterized with scanning electron microscopy, transmission electron microscopy, and X-ray photoelectron spectroscopy. It was found that the CHS-Fe3O4@@ZIF-8 exhibits excellent peroxidase-like activity due to  its ultra-thin hollow layer. Besides, CHS-Fe3O4@@ZIF-8 functionalized with complementary chains of kanamycin aptamer was anchored to the electrode surface via complementary base pairing with the kanamycin aptamer. Upon the presence of kanamycin, a strand displacement reaction was triggered leading to a reduction in the number of the CHS-Fe3O4@@ZIF-8, which slowed down the catalytic reaction of the substrate 3,3',5,5' -tetramethylbenzidine (TMB) facilitated by CHS-Fe3O4@@ZIF 8. Differential pulse voltammetry (DPV) was employed to measure and record changes in peak current resulting from catalytic oxidation product formation (oxidation product of TMB). The electrochemical signal exhibited a linear relationship with logarithmic variations in kanamycin concentration within a range spanning from 10 to 8000 pM and achieved an impressive detection limit as low as 7.52 pM. Furthermore, successful detection of kanamycin content in serum samples using this sensor demonstrated its good specificity and reproducibility. These findings indicate that the constructed electrochemical kanamycin sensor holds significant potential for practical applications. The biosensor demonstrated high selectivity, distinguishing kanamycin from other antibiotics, and exhibited good reproducibility, making it reliable for practical applications. The successful detection of kanamycin in serum samples further underscores the sensor's potential for real-world applications, particularly in monitoring antibiotic residues in food products and clinical diagnostics.

制备具有超薄中空层的 CHS-Fe3O4@@ZIF-8 过氧化物酶模拟物,用于卡那霉素的超灵敏电化学检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信