Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis.

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Zhi-Yong Tian, Meng Li, Jing-Shang Zhang, Ying-Yan Mao, Zhao-Xing Guo, Xin Zheng, Peng Zhao, Xiu-Hua Wan
{"title":"Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis.","authors":"Zhi-Yong Tian, Meng Li, Jing-Shang Zhang, Ying-Yan Mao, Zhao-Xing Guo, Xin Zheng, Peng Zhao, Xiu-Hua Wan","doi":"10.1007/s10792-025-03430-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).</p><p><strong>Methods: </strong>This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024. The outcome measurement was the percentage of eyes with a predicted error (PE) within ± 0.50 or ± 1.00 diopter (D).</p><p><strong>Results: </strong>The study have nine retrospective clinical trials, involving a total of 637 eyes and 18 calculation formulas. According to the ranking based on the surface under the cumulative ranking curve by Bayesian method, the top three formulas were Barrett True-K formula for keratoconus predicted posterior corneal astigmatism (Barrett KC P-PCA), EVO2.0, and Barrett True-K formula for keratoconus measured posterior corneal astigmatism (Barrett KC M-PCA) on the percentage of PE within ± 0.50 D, and the comparison between the three formulas and Barrett Universal II formula has statistical significance. In the range of ± 1.00D, the top three formulas were Barrett KC P-PCA, Barrett KC M-PCA and Kane for keratoconus formula, and the difference was significant. Thereforewe recommend using the Barrett KC P-PCA formula and the Barrett KC M-PCA formula for calculating IOL power in cataract patients with KC.</p><p><strong>Conclusion: </strong>This study revealed that the KC-specific IOL formulas, notably the Barrett KC P-PCA and Barrett KC M-PCA formulas, demonstrated superior accuracy. In clinical practice, when managing patients with different degrees of KC, surgeons should take into account the individual characteristics of each patient and adopt multiple formulas to improve the accuracy of refractive prediction.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":"45 1","pages":"40"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-025-03430-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).

Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024. The outcome measurement was the percentage of eyes with a predicted error (PE) within ± 0.50 or ± 1.00 diopter (D).

Results: The study have nine retrospective clinical trials, involving a total of 637 eyes and 18 calculation formulas. According to the ranking based on the surface under the cumulative ranking curve by Bayesian method, the top three formulas were Barrett True-K formula for keratoconus predicted posterior corneal astigmatism (Barrett KC P-PCA), EVO2.0, and Barrett True-K formula for keratoconus measured posterior corneal astigmatism (Barrett KC M-PCA) on the percentage of PE within ± 0.50 D, and the comparison between the three formulas and Barrett Universal II formula has statistical significance. In the range of ± 1.00D, the top three formulas were Barrett KC P-PCA, Barrett KC M-PCA and Kane for keratoconus formula, and the difference was significant. Thereforewe recommend using the Barrett KC P-PCA formula and the Barrett KC M-PCA formula for calculating IOL power in cataract patients with KC.

Conclusion: This study revealed that the KC-specific IOL formulas, notably the Barrett KC P-PCA and Barrett KC M-PCA formulas, demonstrated superior accuracy. In clinical practice, when managing patients with different degrees of KC, surgeons should take into account the individual characteristics of each patient and adopt multiple formulas to improve the accuracy of refractive prediction.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信