Clinical Characteristics and Outcomes in Heart Failure Patients with Implantable Pulmonary Artery Pressure Monitors: A Single Centre Irish Experience.

IF 2.4 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Niall Leahy, Cillian O'Brien, Sara Essa Alsubai, Eileen Coen, Darragh Murphy, Faisal Sharif
{"title":"Clinical Characteristics and Outcomes in Heart Failure Patients with Implantable Pulmonary Artery Pressure Monitors: A Single Centre Irish Experience.","authors":"Niall Leahy, Cillian O'Brien, Sara Essa Alsubai, Eileen Coen, Darragh Murphy, Faisal Sharif","doi":"10.3390/jcdd12010025","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Hospitalisation for acute decompensated heart failure (HF) portends a poor prognosis. Fluid retention manifesting in dyspnoea and oedema are important clinical features of decompensated heart failure and drive hospital admissions. Intracardiac and pulmonary artery pressure (PAP) monitoring can help predict heart failure decompensation, as changes in these haemodynamics occur before clinical congestion manifests. <b>Methods:</b> A retrospective single centre analysis of patients who underwent insertion of the Cordella™ PA Sensor System (Endotronix, Inc., Chicago, IL, USA) in University Hospital Galway, Ireland, as part of three separate clinical trials-SIRONA 1, SIRONA 2, PROACTIVE HF, was performed. The primary clinical outcome assessed was the difference between HF hospitalisation pre- and post-sensor implantation. <b>Results:</b> In total, there were 33 patients with symptomatic HF who underwent device insertion between 2018 and 2023. All patients had NYHA class 3 heart failure, and 48.5% (<i>n</i> = 16) of patients had HF with reduced ejection fraction. Only one device-related complication was noted, and no pressure sensor failures occurred. In total, there were 26 admissions for HF decompensation 1-year pre-device insertion and only three admissions post-insertion. The difference in the mean number of HF hospitalisations per patient pre- and post-device insertion was 0.70 (<i>p</i> < 0.0001). The difference in mean NYHA class score pre- and post-insertion was 1.0 (<i>p</i> < 0.001). <b>Conclusions:</b> Data from this single-centre cohort study have shown that the insertion of the Cordella™ PA Sensor System in symptomatic HF patients was safe and resulted in statistically significant improvements in HF hospitalisations and NYHA class.</p>","PeriodicalId":15197,"journal":{"name":"Journal of Cardiovascular Development and Disease","volume":"12 1","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11766364/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Development and Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcdd12010025","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Hospitalisation for acute decompensated heart failure (HF) portends a poor prognosis. Fluid retention manifesting in dyspnoea and oedema are important clinical features of decompensated heart failure and drive hospital admissions. Intracardiac and pulmonary artery pressure (PAP) monitoring can help predict heart failure decompensation, as changes in these haemodynamics occur before clinical congestion manifests. Methods: A retrospective single centre analysis of patients who underwent insertion of the Cordella™ PA Sensor System (Endotronix, Inc., Chicago, IL, USA) in University Hospital Galway, Ireland, as part of three separate clinical trials-SIRONA 1, SIRONA 2, PROACTIVE HF, was performed. The primary clinical outcome assessed was the difference between HF hospitalisation pre- and post-sensor implantation. Results: In total, there were 33 patients with symptomatic HF who underwent device insertion between 2018 and 2023. All patients had NYHA class 3 heart failure, and 48.5% (n = 16) of patients had HF with reduced ejection fraction. Only one device-related complication was noted, and no pressure sensor failures occurred. In total, there were 26 admissions for HF decompensation 1-year pre-device insertion and only three admissions post-insertion. The difference in the mean number of HF hospitalisations per patient pre- and post-device insertion was 0.70 (p < 0.0001). The difference in mean NYHA class score pre- and post-insertion was 1.0 (p < 0.001). Conclusions: Data from this single-centre cohort study have shown that the insertion of the Cordella™ PA Sensor System in symptomatic HF patients was safe and resulted in statistically significant improvements in HF hospitalisations and NYHA class.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiovascular Development and Disease
Journal of Cardiovascular Development and Disease CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
12.50%
发文量
381
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信