Cerebral Embolic Protection in Patients Undergoing Left Atrial Appendage Closure.

IF 2.4 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Julia Seeger, Philipp Seppelt, Mario Iturbe-Orbe, David Leistner, Jochen Wöhrle, Michael Joner
{"title":"Cerebral Embolic Protection in Patients Undergoing Left Atrial Appendage Closure.","authors":"Julia Seeger, Philipp Seppelt, Mario Iturbe-Orbe, David Leistner, Jochen Wöhrle, Michael Joner","doi":"10.3390/jcdd12010005","DOIUrl":null,"url":null,"abstract":"<p><p>(1) Background: Cerebral magnetic resonance imaging has reported new cerebral ischemic lesions after left atrial appendage (LAA) closure in about one- third of patients. Stroke occurs predominantly periprocedurally. This study evaluated the characteristics of embolized debris captured by the SENTINEL<sup>TM</sup> cerebral embolic protection system in patients undergoing LAA closure; (2) Methods: Sixty filters of 30 consecutive patients undergoing LAA closure with the WATCHMAN FLX<sup>TM</sup> device were collected and captured debris was analyzed by histopathology and histomorphometry. Clinical outcome measures were disabling and non-disabling stroke within 72 h; (3) Results: In most filters, no material was captured. The predominant captured debris was acute or organized thrombi. The most common pattern was acute fibrin-rich thrombus, which was detected in 11/30 (33.3%) patients. Particles of heart tissue were seen in 6/30 (20%) patients, and foreign material was seen in one (3.3%) patient. The number of particles ranged from 0 to 52 per patient with a maximum of 31 in the distal and 21 in the proximal filter. Particle diameter ranged from 131 to 2614 µm. By logistic regression analysis, only protected time remained a multivariable predictor for larger particles (<i>p</i> = 0.039). There was no disabling or non-disabling stroke. Compared to transfemoral aortic valve replacement, the number of particles is only about 1.5%. (4) Conclusion: LAA occlusion with the WATCHMAN FLX<sup>TM</sup> was associated with a very low number of embolized particles captured with the double-filter SENTINEL<sup>TM</sup> embolic protection system and no periprocedural stroke.</p>","PeriodicalId":15197,"journal":{"name":"Journal of Cardiovascular Development and Disease","volume":"12 1","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11765631/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Development and Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcdd12010005","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

(1) Background: Cerebral magnetic resonance imaging has reported new cerebral ischemic lesions after left atrial appendage (LAA) closure in about one- third of patients. Stroke occurs predominantly periprocedurally. This study evaluated the characteristics of embolized debris captured by the SENTINELTM cerebral embolic protection system in patients undergoing LAA closure; (2) Methods: Sixty filters of 30 consecutive patients undergoing LAA closure with the WATCHMAN FLXTM device were collected and captured debris was analyzed by histopathology and histomorphometry. Clinical outcome measures were disabling and non-disabling stroke within 72 h; (3) Results: In most filters, no material was captured. The predominant captured debris was acute or organized thrombi. The most common pattern was acute fibrin-rich thrombus, which was detected in 11/30 (33.3%) patients. Particles of heart tissue were seen in 6/30 (20%) patients, and foreign material was seen in one (3.3%) patient. The number of particles ranged from 0 to 52 per patient with a maximum of 31 in the distal and 21 in the proximal filter. Particle diameter ranged from 131 to 2614 µm. By logistic regression analysis, only protected time remained a multivariable predictor for larger particles (p = 0.039). There was no disabling or non-disabling stroke. Compared to transfemoral aortic valve replacement, the number of particles is only about 1.5%. (4) Conclusion: LAA occlusion with the WATCHMAN FLXTM was associated with a very low number of embolized particles captured with the double-filter SENTINELTM embolic protection system and no periprocedural stroke.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiovascular Development and Disease
Journal of Cardiovascular Development and Disease CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
12.50%
发文量
381
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信