Development of Hollow Fiber Membranes Suitable for Outside-In Filtration of Human Blood Plasma.

IF 3.3 4区 工程技术 Q2 CHEMISTRY, PHYSICAL
David Ramada, Bente Adema, Mohamed Labib, Odyl Ter Beek, Dimitrios Stamatialis
{"title":"Development of Hollow Fiber Membranes Suitable for Outside-In Filtration of Human Blood Plasma.","authors":"David Ramada, Bente Adema, Mohamed Labib, Odyl Ter Beek, Dimitrios Stamatialis","doi":"10.3390/membranes15010016","DOIUrl":null,"url":null,"abstract":"<p><p>Hemodialysis (HD) is a critical treatment for patients with end-stage kidney disease (ESKD). The effectiveness of conventional dialyzers used there could be compromised during extended use due to limited blood compatibility of synthetic polymeric membranes and sub-optimal dialyzer design. In fact, blood flow in the hollow fiber (HF) membrane could trigger inflammatory responses and thrombus formation, leading to reduced filtration efficiency and limiting therapy duration, a consequence of flowing the patients' blood through the lumen of each fiber while the dialysate passes along the inter-fiber space (IOF, inside-out filtration). This study investigates the development of HF membranes for \"outside-in filtration\" (OIF) in HD. In OIF, blood flows through the inter-fiber space while dialysate flows within the fiber lumens, reducing the risk of fiber clogging and potentially extending treatment duration. For the OIF mode, the membrane should have a blood-compatible outer selective layer in contact with the patient's blood. We develop HFs for OIF via liquid-induced phase separation using PES/PVP (polyethersulphone/polyvinylpyrrolidone) blends. The fibers' surface morphology (SEM, scanning electron microscopy), chemistry (ATR-FTIR-attenuated total reflection-Fourier transform infrared spectroscopy, XPS-X-ray photoelectron spectroscopy), transport properties, and uremic toxin removal from human plasma are evaluated and compared to commercial HFs. These membranes feature a smooth, hydrophilic outer layer, porous lumen, ultrafiltration coefficient of 13-34 mL m<sup>2</sup> h<sup>-1</sup> mmHg<sup>-1</sup>, adequate mechanical properties, low albumin leakage, and toxin removal performance on par with commercial membranes in IOF and OIF. They offer potential for more efficient long-term HD by reducing clogging and systemic anticoagulation needs and enhancing treatment time and toxin clearance.</p>","PeriodicalId":18410,"journal":{"name":"Membranes","volume":"15 1","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11766680/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Membranes","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/membranes15010016","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Hemodialysis (HD) is a critical treatment for patients with end-stage kidney disease (ESKD). The effectiveness of conventional dialyzers used there could be compromised during extended use due to limited blood compatibility of synthetic polymeric membranes and sub-optimal dialyzer design. In fact, blood flow in the hollow fiber (HF) membrane could trigger inflammatory responses and thrombus formation, leading to reduced filtration efficiency and limiting therapy duration, a consequence of flowing the patients' blood through the lumen of each fiber while the dialysate passes along the inter-fiber space (IOF, inside-out filtration). This study investigates the development of HF membranes for "outside-in filtration" (OIF) in HD. In OIF, blood flows through the inter-fiber space while dialysate flows within the fiber lumens, reducing the risk of fiber clogging and potentially extending treatment duration. For the OIF mode, the membrane should have a blood-compatible outer selective layer in contact with the patient's blood. We develop HFs for OIF via liquid-induced phase separation using PES/PVP (polyethersulphone/polyvinylpyrrolidone) blends. The fibers' surface morphology (SEM, scanning electron microscopy), chemistry (ATR-FTIR-attenuated total reflection-Fourier transform infrared spectroscopy, XPS-X-ray photoelectron spectroscopy), transport properties, and uremic toxin removal from human plasma are evaluated and compared to commercial HFs. These membranes feature a smooth, hydrophilic outer layer, porous lumen, ultrafiltration coefficient of 13-34 mL m2 h-1 mmHg-1, adequate mechanical properties, low albumin leakage, and toxin removal performance on par with commercial membranes in IOF and OIF. They offer potential for more efficient long-term HD by reducing clogging and systemic anticoagulation needs and enhancing treatment time and toxin clearance.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Membranes
Membranes Chemical Engineering-Filtration and Separation
CiteScore
6.10
自引率
16.70%
发文量
1071
审稿时长
11 weeks
期刊介绍: Membranes (ISSN 2077-0375) is an international, peer-reviewed open access journal of separation science and technology. It publishes reviews, research articles, communications and technical notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. Full experimental and/or methodical details must be provided.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信