Transient Voltage Information Entropy Difference Unit Protection Based on Fault Condition Attribute Fusion.

IF 2.1 3区 物理与天体物理 Q2 PHYSICS, MULTIDISCIPLINARY
Entropy Pub Date : 2025-01-11 DOI:10.3390/e27010061
Zhenwei Guo, Ruiqiang Zhao, Zebo Huang, Yongyan Jiang, Haojie Li, Yingcai Deng
{"title":"Transient Voltage Information Entropy Difference Unit Protection Based on Fault Condition Attribute Fusion.","authors":"Zhenwei Guo, Ruiqiang Zhao, Zebo Huang, Yongyan Jiang, Haojie Li, Yingcai Deng","doi":"10.3390/e27010061","DOIUrl":null,"url":null,"abstract":"<p><p>Transient protection has the advantage of ultra-high-speed action, but traditional transient protection is susceptible to the influence of two fault condition attributes, namely, transition resistance and initial angle of fault, and there are the problems of insufficient sensitivity and insufficient reliability under weak faults. To this end, the propagation characteristics of high-frequency components of transient voltage in bus and line systems are explored, and a new method of unit protection based on the entropy difference in transient voltage information is proposed. In order to solve the problem of single-ended transient protection not being able to reliably distinguish line faults from bus faults and adjacent line first-end faults, the difference between the entropy of line voltage and the entropy of bus voltage was introduced as a fault characteristic. Aimed at the susceptibility of transient protection to the influence of fault condition attributes, composite fault characteristics containing fault attribute information were obtained by integrating fault characteristics with fault condition attributes to overcome the adverse influence of fault condition attributes on transient protection and improve the reliability of the protection. The algorithm solved 38.9% of the original cross-data, 36.1% of the false actions, and 6.1% of the rejected actions. Finally, the accuracy and reliability of the proposed algorithm were verified by extensive ATP-Draw simulation tests.</p>","PeriodicalId":11694,"journal":{"name":"Entropy","volume":"27 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11764891/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Entropy","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.3390/e27010061","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Transient protection has the advantage of ultra-high-speed action, but traditional transient protection is susceptible to the influence of two fault condition attributes, namely, transition resistance and initial angle of fault, and there are the problems of insufficient sensitivity and insufficient reliability under weak faults. To this end, the propagation characteristics of high-frequency components of transient voltage in bus and line systems are explored, and a new method of unit protection based on the entropy difference in transient voltage information is proposed. In order to solve the problem of single-ended transient protection not being able to reliably distinguish line faults from bus faults and adjacent line first-end faults, the difference between the entropy of line voltage and the entropy of bus voltage was introduced as a fault characteristic. Aimed at the susceptibility of transient protection to the influence of fault condition attributes, composite fault characteristics containing fault attribute information were obtained by integrating fault characteristics with fault condition attributes to overcome the adverse influence of fault condition attributes on transient protection and improve the reliability of the protection. The algorithm solved 38.9% of the original cross-data, 36.1% of the false actions, and 6.1% of the rejected actions. Finally, the accuracy and reliability of the proposed algorithm were verified by extensive ATP-Draw simulation tests.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Entropy
Entropy PHYSICS, MULTIDISCIPLINARY-
CiteScore
4.90
自引率
11.10%
发文量
1580
审稿时长
21.05 days
期刊介绍: Entropy (ISSN 1099-4300), an international and interdisciplinary journal of entropy and information studies, publishes reviews, regular research papers and short notes. Our aim is to encourage scientists to publish as much as possible their theoretical and experimental details. There is no restriction on the length of the papers. If there are computation and the experiment, the details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信