Visual System Inspired Algorithm for Enhanced Visibility in Coronary Angiograms (VIAEVCA).

IF 3.4 3区 医学 Q1 ENGINEERING, MULTIDISCIPLINARY
Hedva Spitzer, Yosef Shai Kashi, Morris Mosseri, Jacob Erel
{"title":"Visual System Inspired Algorithm for Enhanced Visibility in Coronary Angiograms (VIAEVCA).","authors":"Hedva Spitzer, Yosef Shai Kashi, Morris Mosseri, Jacob Erel","doi":"10.3390/biomimetics10010018","DOIUrl":null,"url":null,"abstract":"<p><p>Numerous efforts have been invested in previous algorithms to expose and enhance blood vessel (BV) visibility derived from clinical coronary angiography (CAG) procedures, such as noise reduction, segmentation, and background subtraction. Yet, the visibility of the BVs and their luminal content, particularly the small ones, is still limited. We propose a novel visibility enhancement algorithm, whose main body is inspired by a line completion mechanism of the visual system, i.e., lateral interactions. It facilitates the enhancement of the BVs along with simultaneous noise reduction. In addition, we developed a specific algorithm component that allows better visibility of small BVs and the various CAG tools utilized during the procedure. It is accomplished by enhancing the BVs' fine resolutions, located in the coarse resolutions at the BV zone. The visibility of the most significant clinical features during the CAG procedure was evaluated and qualitatively compared by the consensus of two cardiologists (MM and JE) to the algorithm's results. These included the visibility of the whole frame, the coronary BVs as well as the small ones, the main obstructive lesions within the BVs, and the various angiography interventional tools utilized during the procedure. The algorithm succeeded in producing better visibility of all these features, even under low-contrast or low-radiation conditions. Despite its major advantages, the algorithm also caused the appearance of disturbing vertebral and bony artifacts, which could somewhat lower diagnostic accuracy. Yet, viewing the processed images from multiple angles and not just from a single one and evaluating the cine mode usually overcomes this drawback. Thus, our novel algorithm potentially leads to a better clinical diagnosis, improved procedural capabilities, and a successful outcome.</p>","PeriodicalId":8907,"journal":{"name":"Biomimetics","volume":"10 1","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11760461/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomimetics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/biomimetics10010018","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Numerous efforts have been invested in previous algorithms to expose and enhance blood vessel (BV) visibility derived from clinical coronary angiography (CAG) procedures, such as noise reduction, segmentation, and background subtraction. Yet, the visibility of the BVs and their luminal content, particularly the small ones, is still limited. We propose a novel visibility enhancement algorithm, whose main body is inspired by a line completion mechanism of the visual system, i.e., lateral interactions. It facilitates the enhancement of the BVs along with simultaneous noise reduction. In addition, we developed a specific algorithm component that allows better visibility of small BVs and the various CAG tools utilized during the procedure. It is accomplished by enhancing the BVs' fine resolutions, located in the coarse resolutions at the BV zone. The visibility of the most significant clinical features during the CAG procedure was evaluated and qualitatively compared by the consensus of two cardiologists (MM and JE) to the algorithm's results. These included the visibility of the whole frame, the coronary BVs as well as the small ones, the main obstructive lesions within the BVs, and the various angiography interventional tools utilized during the procedure. The algorithm succeeded in producing better visibility of all these features, even under low-contrast or low-radiation conditions. Despite its major advantages, the algorithm also caused the appearance of disturbing vertebral and bony artifacts, which could somewhat lower diagnostic accuracy. Yet, viewing the processed images from multiple angles and not just from a single one and evaluating the cine mode usually overcomes this drawback. Thus, our novel algorithm potentially leads to a better clinical diagnosis, improved procedural capabilities, and a successful outcome.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomimetics
Biomimetics Biochemistry, Genetics and Molecular Biology-Biotechnology
CiteScore
3.50
自引率
11.10%
发文量
189
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信