Predictors of implant failure: A comprehensive analysis of risk factors in oral implant restoration for patients with partial defects of dentition.

0 MEDICINE, RESEARCH & EXPERIMENTAL
Dake Linghu, Danna Zhang, Min Liu
{"title":"Predictors of implant failure: A comprehensive analysis of risk factors in oral implant restoration for patients with partial defects of dentition.","authors":"Dake Linghu, Danna Zhang, Min Liu","doi":"10.17305/bb.2024.11668","DOIUrl":null,"url":null,"abstract":"<p><p>Implant failure remains a significant challenge in oral implantology, necessitating a deeper understanding of its risk factors to improve treatment outcomes. This study aimed to enhance the clinical outcomes of oral implant restoration by investigating the factors contributing to implant failure in patients with partial dentition defects within two years of treatment. Additionally, the study sought to develop an early risk prediction model for implant failure. A retrospective analysis was conducted on 300 patients with partial dentition defects, dividing them into two groups: a failed implant group and a successful implant group, based on the occurrence of implant failure within two years. General clinical data and condition-specific clinical information were compared between the groups. Multivariate binary logistic regression analysis was used to identify influencing factors, while the predictive effectiveness of the model was assessed using a receiver operating characteristic (ROC) curve. The analysis revealed that factors, such as gender, post-implant smoking, oral hygiene status at the second-year follow-up, tooth position, number of implants, timing of loading, width of keratinized mucosa, and bone quantity significantly influenced the likelihood of implant failure (P < 0.05). Among these, post-implant smoking and tooth position were identified as independent risk factors. The area under the curve (AUC) for tooth position was 0.695, indicating low predictive performance. Although tooth position was determined to be an independent risk factor for implant failure within two years, its predictive performance was limited.</p>","PeriodicalId":72398,"journal":{"name":"Biomolecules & biomedicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomolecules & biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17305/bb.2024.11668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Implant failure remains a significant challenge in oral implantology, necessitating a deeper understanding of its risk factors to improve treatment outcomes. This study aimed to enhance the clinical outcomes of oral implant restoration by investigating the factors contributing to implant failure in patients with partial dentition defects within two years of treatment. Additionally, the study sought to develop an early risk prediction model for implant failure. A retrospective analysis was conducted on 300 patients with partial dentition defects, dividing them into two groups: a failed implant group and a successful implant group, based on the occurrence of implant failure within two years. General clinical data and condition-specific clinical information were compared between the groups. Multivariate binary logistic regression analysis was used to identify influencing factors, while the predictive effectiveness of the model was assessed using a receiver operating characteristic (ROC) curve. The analysis revealed that factors, such as gender, post-implant smoking, oral hygiene status at the second-year follow-up, tooth position, number of implants, timing of loading, width of keratinized mucosa, and bone quantity significantly influenced the likelihood of implant failure (P < 0.05). Among these, post-implant smoking and tooth position were identified as independent risk factors. The area under the curve (AUC) for tooth position was 0.695, indicating low predictive performance. Although tooth position was determined to be an independent risk factor for implant failure within two years, its predictive performance was limited.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信