Mechanism of spillage plumes from multiple openings on ceiling temperature distribution in metro tunnel fires based on superposition principle

IF 6.7 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Zhihe Su , Yanfeng Li , Runzhou Luo , Hua Zhong , Junmei Li , Zhihao Geng , Zhicheng Guo
{"title":"Mechanism of spillage plumes from multiple openings on ceiling temperature distribution in metro tunnel fires based on superposition principle","authors":"Zhihe Su ,&nbsp;Yanfeng Li ,&nbsp;Runzhou Luo ,&nbsp;Hua Zhong ,&nbsp;Junmei Li ,&nbsp;Zhihao Geng ,&nbsp;Zhicheng Guo","doi":"10.1016/j.tust.2025.106412","DOIUrl":null,"url":null,"abstract":"<div><div>This study revisits the coupling effects of tunnel ceiling temperature distribution caused by plume escapes from metro carriage doors during a fire. The impact of fire heat release rates on the ceiling temperature distribution under various door-opening scenarios was analysed by utilising the superposition principle. The concept of virtual fire sources was proposed to model the ceiling temperature distribution associated with plume outflows from carriage doors. The results indicate that the ceiling temperature distribution in a metro tunnel fire is primarily influenced by virtual fire sources generated by plumes escaping through multiple doors. The maximum ceiling temperature from a single virtual fire source was significantly lower than that of a real fire, and the temperature decay followed a double exponential function. The heat flow ratio for each door remained nearly constant for different fire heat release rates, and variations in heat flow with door positions were analysed. The incorporation of heat loss terms into the theoretical model improved the accuracy and quantification of heat loss coefficients. A predictive model for the ceiling temperature distribution caused by metro carriage fires was developed based on the superposition principle, with the predictions well aligning with the experimental results. This study enhances our understanding of the ceiling temperature distribution in multi-opening structures and guides scenarios involving multiple fire sources within tunnels.</div></div>","PeriodicalId":49414,"journal":{"name":"Tunnelling and Underground Space Technology","volume":"158 ","pages":"Article 106412"},"PeriodicalIF":6.7000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tunnelling and Underground Space Technology","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0886779825000501","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study revisits the coupling effects of tunnel ceiling temperature distribution caused by plume escapes from metro carriage doors during a fire. The impact of fire heat release rates on the ceiling temperature distribution under various door-opening scenarios was analysed by utilising the superposition principle. The concept of virtual fire sources was proposed to model the ceiling temperature distribution associated with plume outflows from carriage doors. The results indicate that the ceiling temperature distribution in a metro tunnel fire is primarily influenced by virtual fire sources generated by plumes escaping through multiple doors. The maximum ceiling temperature from a single virtual fire source was significantly lower than that of a real fire, and the temperature decay followed a double exponential function. The heat flow ratio for each door remained nearly constant for different fire heat release rates, and variations in heat flow with door positions were analysed. The incorporation of heat loss terms into the theoretical model improved the accuracy and quantification of heat loss coefficients. A predictive model for the ceiling temperature distribution caused by metro carriage fires was developed based on the superposition principle, with the predictions well aligning with the experimental results. This study enhances our understanding of the ceiling temperature distribution in multi-opening structures and guides scenarios involving multiple fire sources within tunnels.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Tunnelling and Underground Space Technology
Tunnelling and Underground Space Technology 工程技术-工程:土木
CiteScore
11.90
自引率
18.80%
发文量
454
审稿时长
10.8 months
期刊介绍: Tunnelling and Underground Space Technology is an international journal which publishes authoritative articles encompassing the development of innovative uses of underground space and the results of high quality research into improved, more cost-effective techniques for the planning, geo-investigation, design, construction, operation and maintenance of underground and earth-sheltered structures. The journal provides an effective vehicle for the improved worldwide exchange of information on developments in underground technology - and the experience gained from its use - and is strongly committed to publishing papers on the interdisciplinary aspects of creating, planning, and regulating underground space.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信