Development of a time-resolved fluoroimmunoassay for rituximab and its application to therapeutic drug monitoring

IF 3.2 3区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Shangbin Kao , Xiaobin Liu , Juan Jin , Lin Zhang , Ting Shen , Jialong Wu , Yuan Qin , Xiumei Zhou , Xueqin Zhao , Liang Wang , Qiang He , Biao Huang
{"title":"Development of a time-resolved fluoroimmunoassay for rituximab and its application to therapeutic drug monitoring","authors":"Shangbin Kao ,&nbsp;Xiaobin Liu ,&nbsp;Juan Jin ,&nbsp;Lin Zhang ,&nbsp;Ting Shen ,&nbsp;Jialong Wu ,&nbsp;Yuan Qin ,&nbsp;Xiumei Zhou ,&nbsp;Xueqin Zhao ,&nbsp;Liang Wang ,&nbsp;Qiang He ,&nbsp;Biao Huang","doi":"10.1016/j.cca.2025.120142","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Rituximab pharmacokinetics in patients with membranous nephropathy (MN) exhibit significant interindividual variability. Accurate measurement of serum rituximab concentrations is essential for effective therapeutic monitoring. This study develops a highly sensitive time-resolved fluoroimmunoassay (TRFIA) for rituximab (rituximab-TRFIA) with a wide detection range, aimed at enhancing therapeutic drug monitoring in MN treatment.</div></div><div><h3>Methods</h3><div>A capture -type rituximab-TRFIA was developed using streptavidin-coated microplates, biotinylated anti-rituximab idiotypic antibodies, and Eu<sup>3+</sup>-labeled mouse anti-human IgG targeting the Fc fragment of rituximab. The assay was used to measure rituximab serum concentrations in MN patients treated with rituximab.</div></div><div><h3>Results</h3><div>The linear range of rituximab-TRFIA is 0.50 to 2500 ng/mL, with a limit of detection (LOD) of 0.062 ng/mL. The intra-assay coefficient of variation (CV) ranges from 1.97 % to 9.50 %, while the inter-assay CV ranges from 7.44 % to 9.99 %. The recovery rate ranges from 99.14 % to 107.75 %. No cross-reactivity was observed with other monoclonal antibody drugs (mAbs). The detection range is two orders of magnitude higher, and the sensitivity is six times greater than that of the enzyme-linked immunosorbent assay (ELISA). Rituximab-TRFIA showed strong consistency within the same measurement range compared to ELISA (P &lt; 0.0001). The serum rituximab levels in MN patients were significantly higher than those in the control group (P &lt; 0.0001). Among patients who did not achieve remission, 60 % to 70 % had insufficient drug concentrations, and rituximab pharmacokinetics followed the expected trends.</div></div><div><h3>Conclusions</h3><div>The rituximab-TRFIA provides high sensitivity, a wide detection range, and reliable performance for monitoring serum rituximab concentrations in MN patients, supporting personalized treatment strategies.</div></div>","PeriodicalId":10205,"journal":{"name":"Clinica Chimica Acta","volume":"568 ","pages":"Article 120142"},"PeriodicalIF":3.2000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinica Chimica Acta","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S000989812500021X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Rituximab pharmacokinetics in patients with membranous nephropathy (MN) exhibit significant interindividual variability. Accurate measurement of serum rituximab concentrations is essential for effective therapeutic monitoring. This study develops a highly sensitive time-resolved fluoroimmunoassay (TRFIA) for rituximab (rituximab-TRFIA) with a wide detection range, aimed at enhancing therapeutic drug monitoring in MN treatment.

Methods

A capture -type rituximab-TRFIA was developed using streptavidin-coated microplates, biotinylated anti-rituximab idiotypic antibodies, and Eu3+-labeled mouse anti-human IgG targeting the Fc fragment of rituximab. The assay was used to measure rituximab serum concentrations in MN patients treated with rituximab.

Results

The linear range of rituximab-TRFIA is 0.50 to 2500 ng/mL, with a limit of detection (LOD) of 0.062 ng/mL. The intra-assay coefficient of variation (CV) ranges from 1.97 % to 9.50 %, while the inter-assay CV ranges from 7.44 % to 9.99 %. The recovery rate ranges from 99.14 % to 107.75 %. No cross-reactivity was observed with other monoclonal antibody drugs (mAbs). The detection range is two orders of magnitude higher, and the sensitivity is six times greater than that of the enzyme-linked immunosorbent assay (ELISA). Rituximab-TRFIA showed strong consistency within the same measurement range compared to ELISA (P < 0.0001). The serum rituximab levels in MN patients were significantly higher than those in the control group (P < 0.0001). Among patients who did not achieve remission, 60 % to 70 % had insufficient drug concentrations, and rituximab pharmacokinetics followed the expected trends.

Conclusions

The rituximab-TRFIA provides high sensitivity, a wide detection range, and reliable performance for monitoring serum rituximab concentrations in MN patients, supporting personalized treatment strategies.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinica Chimica Acta
Clinica Chimica Acta 医学-医学实验技术
CiteScore
10.10
自引率
2.00%
发文量
1268
审稿时长
23 days
期刊介绍: The Official Journal of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Clinica Chimica Acta is a high-quality journal which publishes original Research Communications in the field of clinical chemistry and laboratory medicine, defined as the diagnostic application of chemistry, biochemistry, immunochemistry, biochemical aspects of hematology, toxicology, and molecular biology to the study of human disease in body fluids and cells. The objective of the journal is to publish novel information leading to a better understanding of biological mechanisms of human diseases, their prevention, diagnosis, and patient management. Reports of an applied clinical character are also welcome. Papers concerned with normal metabolic processes or with constituents of normal cells or body fluids, such as reports of experimental or clinical studies in animals, are only considered when they are clearly and directly relevant to human disease. Evaluation of commercial products have a low priority for publication, unless they are novel or represent a technological breakthrough. Studies dealing with effects of drugs and natural products and studies dealing with the redox status in various diseases are not within the journal''s scope. Development and evaluation of novel analytical methodologies where applicable to diagnostic clinical chemistry and laboratory medicine, including point-of-care testing, and topics on laboratory management and informatics will also be considered. Studies focused on emerging diagnostic technologies and (big) data analysis procedures including digitalization, mobile Health, and artificial Intelligence applied to Laboratory Medicine are also of interest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信