Surface roughness of composite resins subjected to brushing with whitening toothpastes: an in vitro study.

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Brazilian oral research Pub Date : 2025-01-20 eCollection Date: 2025-01-01 DOI:10.1590/1807-3107bor-2025.vol39.006
Nicolle Madruga Ramos Ferreira, Vinicius Funghetto Lippert, Amanda Baptista da Silva Heck, Ana Maria Spohr, Marcel Ferreira Kunrath, Carlos Alberto Feldens, Paulo Floriani Kramer
{"title":"Surface roughness of composite resins subjected to brushing with whitening toothpastes: an in vitro study.","authors":"Nicolle Madruga Ramos Ferreira, Vinicius Funghetto Lippert, Amanda Baptista da Silva Heck, Ana Maria Spohr, Marcel Ferreira Kunrath, Carlos Alberto Feldens, Paulo Floriani Kramer","doi":"10.1590/1807-3107bor-2025.vol39.006","DOIUrl":null,"url":null,"abstract":"<p><p>The emergence of toothpastes containing different abrasive and whitening substances has been a constant concern among dental professionals. The aim of the present study was to perform an in vitro assessment of the surface topography of nanoparticle composite resins subjected to simulated brushing with dentifrices. Test samples were prepared with Filtek Universal (3M ESPE), Filtek Bulkfill (3M ESPE) and Z350 (3M ESPE), with 24 samples per resin. A testing machine was used to simulate brushing with the dentifrices Colgate Total 12, Oral B 100% and Oral B Gengiva Detox Gentle Whitening (8 samples per group). The constant speed of the machine was 250 cycles per minute, and 20.000 cycles were carried out, which corresponds to 24 months (1 hour and 20 minutes). Roughness features and qualitative surface topography were investigated. Statistical analysis involved the Kruskal-Wallis, Wilcoxon and Mann-Whitney tests. A significant increase in surface roughness was found for all the resins (p < 0.05). However, no significant difference was found among the resins in terms of final roughness values (p = 0.690). In contrast, a significant difference among dentifrices was found with respect to roughness measurements (p < 0.001). The qualitative analysis revealed an increase in surface roughness in all the samples and differences in the abrasive potential of the dentifrices. In conclusion, brushing with dentifrices increases the surface roughness parameters of composite resin restorations. Moreover, the differences in the abrasive effects of the dentifrices indicate a need for further studies to establish efficacy and safety criteria.</p>","PeriodicalId":9240,"journal":{"name":"Brazilian oral research","volume":"39 ","pages":"e006"},"PeriodicalIF":1.5000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11745460/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian oral research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1807-3107bor-2025.vol39.006","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

The emergence of toothpastes containing different abrasive and whitening substances has been a constant concern among dental professionals. The aim of the present study was to perform an in vitro assessment of the surface topography of nanoparticle composite resins subjected to simulated brushing with dentifrices. Test samples were prepared with Filtek Universal (3M ESPE), Filtek Bulkfill (3M ESPE) and Z350 (3M ESPE), with 24 samples per resin. A testing machine was used to simulate brushing with the dentifrices Colgate Total 12, Oral B 100% and Oral B Gengiva Detox Gentle Whitening (8 samples per group). The constant speed of the machine was 250 cycles per minute, and 20.000 cycles were carried out, which corresponds to 24 months (1 hour and 20 minutes). Roughness features and qualitative surface topography were investigated. Statistical analysis involved the Kruskal-Wallis, Wilcoxon and Mann-Whitney tests. A significant increase in surface roughness was found for all the resins (p < 0.05). However, no significant difference was found among the resins in terms of final roughness values (p = 0.690). In contrast, a significant difference among dentifrices was found with respect to roughness measurements (p < 0.001). The qualitative analysis revealed an increase in surface roughness in all the samples and differences in the abrasive potential of the dentifrices. In conclusion, brushing with dentifrices increases the surface roughness parameters of composite resin restorations. Moreover, the differences in the abrasive effects of the dentifrices indicate a need for further studies to establish efficacy and safety criteria.

美白牙膏对复合树脂表面粗糙度的影响:体外研究。
含有不同磨料和美白物质的牙膏的出现一直是牙科专业人员关注的问题。本研究的目的是在体外评估纳米颗粒复合树脂在模拟刷牙时的表面形貌。测试样品采用Filtek Universal (3M ESPE)、Filtek Bulkfill (3M ESPE)和Z350 (3M ESPE)制备,每种树脂24个样品。采用测试机模拟使用高露洁Total 12、Oral B 100%和Oral B Gengiva排毒温和美白牙膏刷牙(每组8个样品)。机器的恒转速为每分钟250圈,进行了20000圈,相当于24个月(1小时20分钟)。研究了表面粗糙度特征和定性表面形貌。统计分析包括Kruskal-Wallis, Wilcoxon和Mann-Whitney测试。所有树脂的表面粗糙度均显著增加(p < 0.05)。然而,在最终粗糙度值方面,树脂之间没有显著差异(p = 0.690)。相比之下,在粗糙度测量方面,不同牙菌种之间存在显著差异(p < 0.001)。定性分析表明,所有样品的表面粗糙度都有所增加,并且牙齿的磨蚀电位也有所不同。综上所述,用牙刷可以增加复合树脂修复体的表面粗糙度参数。此外,在磨蚀作用的差异表明,需要进一步的研究,以建立有效性和安全性标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.70
自引率
4.00%
发文量
107
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信