{"title":"A bis-pyrene polyamine receptor for fast optical detection of ketoprofen: synthesis, characterization and application in all-solid-state fluorescent sensors","authors":"Giammarco Maria Romano, Pierangela Di Menna, Andrea Bencini, Yschtar Tecla Simonini Steiner, Massimo Innocenti, Corrado Di Natale, Roberto Paolesse, Larisa Lvova","doi":"10.1039/d4an01469c","DOIUrl":null,"url":null,"abstract":"Here we report on a polyamine receptor L1 bearing pyrene fluorogenic groups for the optical assessment of non-opioid analgesic drug ketoprofen, KP. L1, composed of a diethylenetriamine moiety linked at its extremities to the 1 position of two pyrene units via methylene linkers, gives an emission at 460 nm in water/ethanol 1:1 (v:v) mixture at pH 7, likely due to the excimer formation between the two aromatic groups.. In the presence of KP a salt bridging interaction between the carboxylate group of the analyte and the central ammonium group of L1 induces a redistribution of the acidic protons in the polyamine chain causing a marked increase of the emission. This optical signal was used to detect KP in aqueous media. Inspired by this observation, the properties of all-solid-state optodes with plasticized PVC membranes doped with L1 and deposited on the appropriate solid support material were further tested. The best membrane contained 1wt% of fully protonated L1, plasticized with DOS and doped with 3 equiv. of TDMACl anion-exchanger. It was able to detect KP in 2μM–0.1mM range with a low influence of interfering ions and applied for KP assessment in OkiTask with RSD of 2.1% and recovery of 102%. Moreover, the possibility to low down the KP DL to 0.84 μM (0.21mg/L) through the application of L1 based fluorescent sensor array and chemometrics was shown.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"33 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4an01469c","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Here we report on a polyamine receptor L1 bearing pyrene fluorogenic groups for the optical assessment of non-opioid analgesic drug ketoprofen, KP. L1, composed of a diethylenetriamine moiety linked at its extremities to the 1 position of two pyrene units via methylene linkers, gives an emission at 460 nm in water/ethanol 1:1 (v:v) mixture at pH 7, likely due to the excimer formation between the two aromatic groups.. In the presence of KP a salt bridging interaction between the carboxylate group of the analyte and the central ammonium group of L1 induces a redistribution of the acidic protons in the polyamine chain causing a marked increase of the emission. This optical signal was used to detect KP in aqueous media. Inspired by this observation, the properties of all-solid-state optodes with plasticized PVC membranes doped with L1 and deposited on the appropriate solid support material were further tested. The best membrane contained 1wt% of fully protonated L1, plasticized with DOS and doped with 3 equiv. of TDMACl anion-exchanger. It was able to detect KP in 2μM–0.1mM range with a low influence of interfering ions and applied for KP assessment in OkiTask with RSD of 2.1% and recovery of 102%. Moreover, the possibility to low down the KP DL to 0.84 μM (0.21mg/L) through the application of L1 based fluorescent sensor array and chemometrics was shown.
用于酮洛芬快速光学检测的双芘多胺受体:合成、表征及其在全固态荧光传感器中的应用
在这里,我们报道了多胺受体L1携带芘荧光基团用于非阿片类镇痛药物酮洛芬KP的光学评估。在pH为7的水/乙醇1:1 (v:v)混合物中,由二乙烯三胺部分通过亚甲基连接到两个芘单元的1位组成的L1在460 nm处发出辐射,可能是由于两个芳香基团之间形成了准分子。在KP存在的情况下,分析物的羧酸基和L1的中心铵基之间的盐桥接相互作用诱导了多胺链中酸性质子的重新分配,导致辐射显著增加。该光信号被用于检测水介质中的KP。受这一观察结果的启发,我们进一步测试了掺杂L1的塑化PVC膜并沉积在适当的固体支撑材料上的全固态光电器件的性能。最好的膜含有1wt%的完全质子化L1,用DOS塑化,并掺杂3等量的TDMACl阴离子交换剂。该方法在2μM-0.1mM范围内检测KP,干扰离子影响小,可用于OkiTask中KP的测定,RSD为2.1%,回收率为102%。此外,通过L1荧光传感器阵列和化学计量学的应用,可以将KP DL降低到0.84 μM (0.21mg/L)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信