{"title":"Eye lens dosimetry: does the direction of rotation (vertical or horizontal) play a role in type testing?","authors":"Behnam Khanbabaee, Rolf Behrens, Onur Erdem","doi":"10.1088/1361-6498/adaaff","DOIUrl":null,"url":null,"abstract":"<p><p>With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm,<i>H</i><sub>p</sub>(3), is the measurement method for monitoring the dose to the lens of the eye. Usual dosemeter type-test irradiations at non-normal angles of radiation incidence (<i>α</i>≠ 0°) primarily use lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating rotation of the dosemeter-phantom setup around a vertical axis. However, this method does not adequately account for bottom-to-top radiation exposures which are common in real-world situations (such as radiation scattered by a patient reaching medical staff). This study examines oblique radiation exposure conditions using a typical eye lens thermoluminescent dosemeter (TLD), Eye-D, placed on a cylindrical phantom to assess dose response at different angles and exposure energies. The study employs both low-energy (N-30 radiation quality with a mean photon energy of 25 keV) and medium-energy (N-100 radiation quality with a mean photon energy of 83 keV) x-rays at irradiation angles of<b>-</b>60°, 0°, and +60°, measured along the vertical and horizontal rotation axes of the dosemeter-phantom setup. The results show no significant difference between horizontal and vertical (polar and radial) rotation orientations of the dosemeter-phantom setup: recorded relative doses stayed well within ± 1 %, i.e. by far within the attributed combined uncertainty of ± 2 %.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/adaaff","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm,Hp(3), is the measurement method for monitoring the dose to the lens of the eye. Usual dosemeter type-test irradiations at non-normal angles of radiation incidence (α≠ 0°) primarily use lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating rotation of the dosemeter-phantom setup around a vertical axis. However, this method does not adequately account for bottom-to-top radiation exposures which are common in real-world situations (such as radiation scattered by a patient reaching medical staff). This study examines oblique radiation exposure conditions using a typical eye lens thermoluminescent dosemeter (TLD), Eye-D, placed on a cylindrical phantom to assess dose response at different angles and exposure energies. The study employs both low-energy (N-30 radiation quality with a mean photon energy of 25 keV) and medium-energy (N-100 radiation quality with a mean photon energy of 83 keV) x-rays at irradiation angles of-60°, 0°, and +60°, measured along the vertical and horizontal rotation axes of the dosemeter-phantom setup. The results show no significant difference between horizontal and vertical (polar and radial) rotation orientations of the dosemeter-phantom setup: recorded relative doses stayed well within ± 1 %, i.e. by far within the attributed combined uncertainty of ± 2 %.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.