Interobserver and intraobserver variability among different vendors for mitral valve assessment: implications for transcatheter mitral valve repair.

IF 9.7 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Apurva B Challa, Monika Radike, Asim Rizvi, Nikkole M Weber, Malgorzata Wamil, Shivaram Poigai Arunachalam, Emily Sheedy, Shuai Leng, Eric E Williamson
{"title":"Interobserver and intraobserver variability among different vendors for mitral valve assessment: implications for transcatheter mitral valve repair.","authors":"Apurva B Challa, Monika Radike, Asim Rizvi, Nikkole M Weber, Malgorzata Wamil, Shivaram Poigai Arunachalam, Emily Sheedy, Shuai Leng, Eric E Williamson","doi":"10.1007/s11547-025-01950-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Pre-procedural imaging is critical for transcatheter mitral valve repair planning in patients with mitral valve disease. As differences among various measurement techniques for valve evaluation are still poorly understood, we sought to assess the intra- and interobserver agreement of complex measurements derived from a prototype mitral evaluation tool (Siemens) and a commercially available tool (CVI42) using both saddle- and D-shaped mitral annulus techniques.</p><p><strong>Materials and methods: </strong>Multiphasic cardiac computed tomography angiography data were loaded into each software. Three expert readers independently measured the annuli on systolic- and diastolic-phase images using both tools. Measurement agreement between the tools was assessed with t tests, with p ≤ 0.05 considered statistically significant. Intraclass correlation coefficient (ICC) was used for interobserver agreement. Bland-Altman plots were used to assess for systematic differences.</p><p><strong>Results: </strong>Ten patients (mean age: 61.9 ± 9.9 years, 70%males) were included, with either normal mitral valve (n = 5) or with primary mitral regurgitation (n = 5). The intraobserver comparison showed statistically significantly different circumference and planar surface areas only for one reader in each group. However, there was significant difference (p ≤ 0.05) between measurements for intercommissural distance, septolateral distance, and intertrigone distance. The interobserver agreement was good (ICC, 0.60-0.74) to excellent (ICC, 0.75-1.00). There were systematic differences in mitral annulus area parameters for both saddle- and D-shaped annulus.</p><p><strong>Conclusion: </strong>Both tools effectively assess mitral annulus with good-to-excellent interobserver agreement. As there were systematic differences in the annular area and distance, use of the same software should be considered in clinical and research workflows.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":""},"PeriodicalIF":9.7000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-025-01950-y","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Pre-procedural imaging is critical for transcatheter mitral valve repair planning in patients with mitral valve disease. As differences among various measurement techniques for valve evaluation are still poorly understood, we sought to assess the intra- and interobserver agreement of complex measurements derived from a prototype mitral evaluation tool (Siemens) and a commercially available tool (CVI42) using both saddle- and D-shaped mitral annulus techniques.

Materials and methods: Multiphasic cardiac computed tomography angiography data were loaded into each software. Three expert readers independently measured the annuli on systolic- and diastolic-phase images using both tools. Measurement agreement between the tools was assessed with t tests, with p ≤ 0.05 considered statistically significant. Intraclass correlation coefficient (ICC) was used for interobserver agreement. Bland-Altman plots were used to assess for systematic differences.

Results: Ten patients (mean age: 61.9 ± 9.9 years, 70%males) were included, with either normal mitral valve (n = 5) or with primary mitral regurgitation (n = 5). The intraobserver comparison showed statistically significantly different circumference and planar surface areas only for one reader in each group. However, there was significant difference (p ≤ 0.05) between measurements for intercommissural distance, septolateral distance, and intertrigone distance. The interobserver agreement was good (ICC, 0.60-0.74) to excellent (ICC, 0.75-1.00). There were systematic differences in mitral annulus area parameters for both saddle- and D-shaped annulus.

Conclusion: Both tools effectively assess mitral annulus with good-to-excellent interobserver agreement. As there were systematic differences in the annular area and distance, use of the same software should be considered in clinical and research workflows.

不同供应商对二尖瓣评估的观察者之间和观察者内部差异:对经导管二尖瓣修复的影响。
目的:术前影像对经导管二尖瓣疾病患者的二尖瓣修复计划至关重要。由于各种瓣膜评估测量技术之间的差异仍然知之甚少,我们试图评估来自二尖瓣评估工具原型(Siemens)和商用工具(CVI42)的复杂测量在观察者内部和观察者之间的一致性,这些工具使用鞍形和d形二尖瓣环技术。材料和方法:将多相心脏计算机断层血管造影数据加载到各软件中。三位专家读者分别使用这两种工具在收缩期和舒张期图像上测量了环空。采用t检验评估工具之间的测量一致性,p≤0.05认为具有统计学意义。类内相关系数(ICC)用于观察者间的一致性。Bland-Altman图用于评估系统差异。结果:纳入10例患者(平均年龄:61.9±9.9岁,70%为男性),二尖瓣正常(n = 5)或原发性二尖瓣反流(n = 5)。观察者内比较显示,每组中只有一名读者的周长和平面面积有统计学意义上的差异。然而,关节间距离、隔侧距离和三角间距离的测量差异有统计学意义(p≤0.05)。观察者间的一致性为良好(ICC, 0.60-0.74)至优秀(ICC, 0.75-1.00)。鞍形环和d形环的二尖瓣面积参数有系统差异。结论:两种工具都能有效评估二尖瓣环,观察者之间的一致性良好。由于环的面积和距离存在系统性差异,在临床和研究工作流程中应考虑使用相同的软件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiologia Medica
Radiologia Medica 医学-核医学
CiteScore
14.10
自引率
7.90%
发文量
133
审稿时长
4-8 weeks
期刊介绍: Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信