{"title":"Comparative analysis of axial length measurement method for eyes with submacular hemorrhage.","authors":"Masakazu Nagayama, Shuhei Kimura, Mio Morizane Hosokawa, Yusuke Shiode, Ryo Matoba, Tetsuro Morita, Keisuke Kanenaga, Yuki Morizane","doi":"10.1007/s10384-024-01147-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To identify a method for comparing preoperative axial length (AL) measurements with postoperative AL in submacular hemorrhage (SMH).</p><p><strong>Study design: </strong>Retrospective.</p><p><strong>Methods: </strong>This study included 30 patients who underwent vitrectomy for SMH (January 2016-January 2023) with preoperative and postoperative AL data. Preoperative AL was obtained using ultrasonography for the affected eye (aUS-AL) and compared to those measured using optical biometry (OB) for the affected and fellow eyes (aOB-AL and fOB-AL, respectively). Postoperative AL (aPost-AL) was defined as the AL of the affected eye by OB. The absolute differences between the preoperative AL (aUS-AL, aOB-AL, and fOB-AL) and aPost-AL were assessed.</p><p><strong>Results: </strong>aUS-AL, aOB-AL, and fOB-AL values were 23.50 ± 1.41 mm, 23.32 ± 1.40 mm, and 23.66 ± 1.45 mm, respectively, correlating strongly with aPost-AL (23.54 ± 1.37 mm) (all R > 0.95). fOB-AL exceeded aPost-AL significantly (P = 0.02). In all 30 eyes, absolute differences between preoperative AL and aPost-AL were 0.19 ± 0.18 mm, 0.28 ± 0.32 mm, and 0.21 ± 0.22 mm, respectively, which were not significantly different from each other (all P > 0.05). In nine eyes with SMH height > 1000 μm or unmeasurable, the absolute difference between aOB-AL and aPost-AL (0.42 ± 0.33 mm) exceeded that of aUS-AL and aPost-AL (0.10 ± 0.09 mm) (P = 0.003).</p><p><strong>Conclusion: </strong>Although aUS-AL, aOB-AL, and fOB-AL correlated well with postoperative AL in patients with SMH, fOB-AL may be measured longer and aOB-AL shorter in some cases. Therefore, aUS-AL may be considered primarily in determining IOL power of cataract surgery performed in combination with SMH displacement.</p>","PeriodicalId":14563,"journal":{"name":"Japanese Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10384-024-01147-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To identify a method for comparing preoperative axial length (AL) measurements with postoperative AL in submacular hemorrhage (SMH).
Study design: Retrospective.
Methods: This study included 30 patients who underwent vitrectomy for SMH (January 2016-January 2023) with preoperative and postoperative AL data. Preoperative AL was obtained using ultrasonography for the affected eye (aUS-AL) and compared to those measured using optical biometry (OB) for the affected and fellow eyes (aOB-AL and fOB-AL, respectively). Postoperative AL (aPost-AL) was defined as the AL of the affected eye by OB. The absolute differences between the preoperative AL (aUS-AL, aOB-AL, and fOB-AL) and aPost-AL were assessed.
Results: aUS-AL, aOB-AL, and fOB-AL values were 23.50 ± 1.41 mm, 23.32 ± 1.40 mm, and 23.66 ± 1.45 mm, respectively, correlating strongly with aPost-AL (23.54 ± 1.37 mm) (all R > 0.95). fOB-AL exceeded aPost-AL significantly (P = 0.02). In all 30 eyes, absolute differences between preoperative AL and aPost-AL were 0.19 ± 0.18 mm, 0.28 ± 0.32 mm, and 0.21 ± 0.22 mm, respectively, which were not significantly different from each other (all P > 0.05). In nine eyes with SMH height > 1000 μm or unmeasurable, the absolute difference between aOB-AL and aPost-AL (0.42 ± 0.33 mm) exceeded that of aUS-AL and aPost-AL (0.10 ± 0.09 mm) (P = 0.003).
Conclusion: Although aUS-AL, aOB-AL, and fOB-AL correlated well with postoperative AL in patients with SMH, fOB-AL may be measured longer and aOB-AL shorter in some cases. Therefore, aUS-AL may be considered primarily in determining IOL power of cataract surgery performed in combination with SMH displacement.
期刊介绍:
The Japanese Journal of Ophthalmology (JJO) was inaugurated in 1957 as a quarterly journal published in English by the Ophthalmology Department of the University of Tokyo, with the aim of disseminating the achievements of Japanese ophthalmologists worldwide. JJO remains the only Japanese ophthalmology journal published in English. In 1997, the Japanese Ophthalmological Society assumed the responsibility for publishing the Japanese Journal of Ophthalmology as its official English-language publication.
Currently the journal is published bimonthly and accepts papers from authors worldwide. JJO has become an international interdisciplinary forum for the publication of basic science and clinical research papers.