A Highly Sensitive Triple Quad LC–MS/MS Method Development and Validation for the Determination of Bexicaserin (LP352) in Human Plasma and Urine Matrices

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Raja Reddy Kallem, Maisy Yeager, Rosa Chan, Katharine Fletcher, Katie Neal, Nuggehally R. Srinivas
{"title":"A Highly Sensitive Triple Quad LC–MS/MS Method Development and Validation for the Determination of Bexicaserin (LP352) in Human Plasma and Urine Matrices","authors":"Raja Reddy Kallem,&nbsp;Maisy Yeager,&nbsp;Rosa Chan,&nbsp;Katharine Fletcher,&nbsp;Katie Neal,&nbsp;Nuggehally R. Srinivas","doi":"10.1002/bmc.6079","DOIUrl":null,"url":null,"abstract":"<p>Bexicaserin is a highly selective agonist at the 5-HT<sub>2c</sub> receptor in clinical development for the treatment of seizures associated with developmental and epileptic encephalopathies (DEEs). We report an LC–MS/MS method for the quantitative estimation of bexicaserin in human plasma and urine. The sample preparation involves the extraction of bexicaserin and internal standard (<sup>13</sup>CD<sub>2</sub>-bexicaserin; IS) from 150 μL plasma and 50 μL urine using a solid phase extraction method. The chromatographic separation of bexicaserin and IS was achieved on a Poroshell EC-C18 column using 5 min gradient program. The calibration curve ranged from 0.1 to 100 ng/mL in plasma and 1.0 to 1000 ng/mL in urine. Intraday and interday precision and accuracy, linearity, matrix effect, extraction recovery, carry-over, dilution integrity, a battery of stability studies, and incurred sample reanalysis were performed for bexicaserin in both plasma and urine. The intraday and interday accuracy and precision were well within the acceptable limits in both plasma and urine matrices. Stability studies in plasma and urine showed that bexicaserin was stable on bench for 24 h, in autosampler over 54 h, five freeze–thaw cycles, and long-term storage at −20°C and −80°C for &gt; 368 days. The validated methods were successfully applied in clinical study.</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 2","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753905/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.6079","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Bexicaserin is a highly selective agonist at the 5-HT2c receptor in clinical development for the treatment of seizures associated with developmental and epileptic encephalopathies (DEEs). We report an LC–MS/MS method for the quantitative estimation of bexicaserin in human plasma and urine. The sample preparation involves the extraction of bexicaserin and internal standard (13CD2-bexicaserin; IS) from 150 μL plasma and 50 μL urine using a solid phase extraction method. The chromatographic separation of bexicaserin and IS was achieved on a Poroshell EC-C18 column using 5 min gradient program. The calibration curve ranged from 0.1 to 100 ng/mL in plasma and 1.0 to 1000 ng/mL in urine. Intraday and interday precision and accuracy, linearity, matrix effect, extraction recovery, carry-over, dilution integrity, a battery of stability studies, and incurred sample reanalysis were performed for bexicaserin in both plasma and urine. The intraday and interday accuracy and precision were well within the acceptable limits in both plasma and urine matrices. Stability studies in plasma and urine showed that bexicaserin was stable on bench for 24 h, in autosampler over 54 h, five freeze–thaw cycles, and long-term storage at −20°C and −80°C for > 368 days. The validated methods were successfully applied in clinical study.

高灵敏度三重四联质谱/质谱法测定人血浆和尿液基质中贝西卡塞林(LP352)的建立与验证
贝西卡塞林是一种高度选择性的5-HT2c受体激动剂,用于治疗与发育性和癫痫性脑病(dei)相关的癫痫发作。我们报道了一种LC-MS/MS定量测定人血浆和尿液中贝西卡塞林的方法。样品制备包括提取贝西沙塞林和内标(13cd2 -贝西沙塞林;采用固相萃取法从150 μL血浆和50 μL尿液中提取IS)。采用5 min梯度程序,在Poroshell EC-C18色谱柱上实现贝西卡塞林和IS的色谱分离。血浆中的校准曲线范围为0.1 ~ 100 ng/mL,尿液中的校准曲线范围为1.0 ~ 1000 ng/mL。对血浆和尿液中的贝西卡塞林进行了当日和日间的精密度和准确度、线性、基质效应、提取回收率、结转、稀释完整性、一系列稳定性研究和发生的样品再分析。血浆和尿液基质的当日和日间准确度和精密度均在可接受范围内。血浆和尿液的稳定性研究表明,贝昔卡塞林在实验台上稳定24 h,在自动进样器中稳定54 h,冻融循环5次,在-20°C和-80°C条件下长期保存368天。验证的方法已成功应用于临床研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信