{"title":"Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.","authors":"Yimeng Kang, Wenjing Li, Qingqing Lv, Qiuying Tao, Jieping Sun, Jinghan Dang, Xiaoyu Niu, Zijun Liu, Shujian Li, Zanxia Zhang, Kaiyu Wang, Baohong Wen, Jingliang Cheng, Yong Zhang, Weijian Wang","doi":"10.1186/s12880-025-01554-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.</p><p><strong>Methods: </strong>We enrolled a cohort of sixty patients who underwent DL-MRI, conventional MRI, and No-DL MRI examinations to evaluate image quality. Key metrics considered in the assessment included scan duration, overall image quality, quantitative assessments of Relative Signal-to-Noise Ratio (rSNR), Relative Contrast-to-Noise Ratio (rCNR), and diagnostic efficacy. Two experienced radiologists independently assessed image quality using a 5-point scale (5 indicating the highest quality). To gauge interobserver agreement for the assessed pathologies across image sets, we employed weighted kappa statistics. Additionally, the Wilcoxon signed rank test was employed to compare image quality and quantitative rSNR and rCNR measurements.</p><p><strong>Results: </strong>Scan time was significantly reduced with DL-MRI and represented an approximate 66.5% reduction. DL-MRI consistently exhibited superior image quality in both coronal T2WI and axial T2WI when compared to both conventional MRI (p < 0.01) and No-DL-MRI (p < 0.01). Interobserver agreement was robust, with kappa values exceeding 0.735. For rSNR data, coronal fat-saturated(FS) T2WI and axial FS T2WI in DL-MRI consistently outperformed No-DL-MRI, with statistical significance (p < 0.01) observed in all cases. Similarly, rCNR data revealed significant improvements (p < 0.01) in coronal FS T2WI of DL-MRI when compared to No-DL-MRI. Importantly, our findings indicated that DL-MRI demonstrated diagnostic performance comparable to conventional MRI.</p><p><strong>Conclusion: </strong>Integrating deep learning-based reconstruction methods into standard clinical workflows has the potential to the promise of accelerating image acquisition, enhancing image clarity, and increasing patient throughput, thereby optimizing diagnostic efficiency.</p><p><strong>Trial registration: </strong>Retrospectively registered.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"17"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-025-01554-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

Methods: We enrolled a cohort of sixty patients who underwent DL-MRI, conventional MRI, and No-DL MRI examinations to evaluate image quality. Key metrics considered in the assessment included scan duration, overall image quality, quantitative assessments of Relative Signal-to-Noise Ratio (rSNR), Relative Contrast-to-Noise Ratio (rCNR), and diagnostic efficacy. Two experienced radiologists independently assessed image quality using a 5-point scale (5 indicating the highest quality). To gauge interobserver agreement for the assessed pathologies across image sets, we employed weighted kappa statistics. Additionally, the Wilcoxon signed rank test was employed to compare image quality and quantitative rSNR and rCNR measurements.

Results: Scan time was significantly reduced with DL-MRI and represented an approximate 66.5% reduction. DL-MRI consistently exhibited superior image quality in both coronal T2WI and axial T2WI when compared to both conventional MRI (p < 0.01) and No-DL-MRI (p < 0.01). Interobserver agreement was robust, with kappa values exceeding 0.735. For rSNR data, coronal fat-saturated(FS) T2WI and axial FS T2WI in DL-MRI consistently outperformed No-DL-MRI, with statistical significance (p < 0.01) observed in all cases. Similarly, rCNR data revealed significant improvements (p < 0.01) in coronal FS T2WI of DL-MRI when compared to No-DL-MRI. Importantly, our findings indicated that DL-MRI demonstrated diagnostic performance comparable to conventional MRI.

Conclusion: Integrating deep learning-based reconstruction methods into standard clinical workflows has the potential to the promise of accelerating image acquisition, enhancing image clarity, and increasing patient throughput, thereby optimizing diagnostic efficiency.

Trial registration: Retrospectively registered.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信