{"title":"Risk factors for the recurrence of atrial fibrillation after catheter ablation: a meta-analysis.","authors":"Gonghao Li, Yanli Zhao, Zhongxing Peng, Yunfeng Zhao","doi":"10.1186/s43044-025-00605-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The rate at which atrial fibrillation (AF) patients experience a return of symptoms after catheter ablation is significant, and there are multiple risk factors involved. This research intends to perform a meta-analysis to explore the risk factors connected to the recurrence of AF in patients following catheter ablation.</p><p><strong>Methods: </strong>The PubMed, Cochrane Library, WOS, Embase, SinoMed, CNKI, Wanfang, and VIP databases were explored for studies from January 1, 2000 to August 10, 2021, and research meeting the established inclusion requirements was chosen. Two authors separately gathered details regarding the study structure. The strength of the link between various risk factors and AF returning after CA was evaluated using odds ratios. All statistical evaluations were conducted with RevMan5.3 software.</p><p><strong>Results: </strong>In total, 44 articles and 62,674 patients were included. The OR for AF recurrence in patients with diabetes was 2.04 compared with the reference group (95% CI 1.51-2.76, p < 0.00001); that of lower left ventricular ejection fraction was 1.38 (95% CI 1.25-1.52, p < 0.00001); that of female was 1.34 (95% CI 1.18-1.52, p < 0.00001); that of increased age was 1.03 (95% CI 1.02-1.04, p < 0.00001); that of persistent AF was 1.72 (95% CI 1.58-1.87, p < 0.00001); that of AF duration over 2 years was 1.17 (95% CI 1.08-1.26, p < 0.00001); that of increased left atrial diameter (LAD) was 1.12 (95% CI 1.08-1.17, p < 0.00001); that of larger left atrial volume index (LAVi) was 1.02 (95% CI 1.01-1.03, p < 0.00001); that of higher hs-CRP was 1.19 (95% CI 1.04-1.36, p = 0.04); that of early recurrence (ER) was 3.22 (95% CI 2.74-3.77, p < 0.00001); and that of long ablation duration was 1.00 (95% CI 0.98-1.02, p = 0.72). Heterogeneity and slight publication bias were observed for each factor.</p><p><strong>Conclusions: </strong>Evidence indicates that diabetes, low left ventricular ejection fraction, being female, older age, longer duration of atrial fibrillation, elevated high-sensitivity C-reactive protein levels, large left atrial dimension, large left atrial volume index, persistent atrial fibrillation, and exercise rehabilitation are factors that increase the chances of getting atrial fibrillation again after catheter ablation. However, the length of the ablation procedure does not relate to the recurrence of AF.</p>","PeriodicalId":74993,"journal":{"name":"The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology","volume":"77 1","pages":"9"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11729607/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43044-025-00605-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The rate at which atrial fibrillation (AF) patients experience a return of symptoms after catheter ablation is significant, and there are multiple risk factors involved. This research intends to perform a meta-analysis to explore the risk factors connected to the recurrence of AF in patients following catheter ablation.
Methods: The PubMed, Cochrane Library, WOS, Embase, SinoMed, CNKI, Wanfang, and VIP databases were explored for studies from January 1, 2000 to August 10, 2021, and research meeting the established inclusion requirements was chosen. Two authors separately gathered details regarding the study structure. The strength of the link between various risk factors and AF returning after CA was evaluated using odds ratios. All statistical evaluations were conducted with RevMan5.3 software.
Results: In total, 44 articles and 62,674 patients were included. The OR for AF recurrence in patients with diabetes was 2.04 compared with the reference group (95% CI 1.51-2.76, p < 0.00001); that of lower left ventricular ejection fraction was 1.38 (95% CI 1.25-1.52, p < 0.00001); that of female was 1.34 (95% CI 1.18-1.52, p < 0.00001); that of increased age was 1.03 (95% CI 1.02-1.04, p < 0.00001); that of persistent AF was 1.72 (95% CI 1.58-1.87, p < 0.00001); that of AF duration over 2 years was 1.17 (95% CI 1.08-1.26, p < 0.00001); that of increased left atrial diameter (LAD) was 1.12 (95% CI 1.08-1.17, p < 0.00001); that of larger left atrial volume index (LAVi) was 1.02 (95% CI 1.01-1.03, p < 0.00001); that of higher hs-CRP was 1.19 (95% CI 1.04-1.36, p = 0.04); that of early recurrence (ER) was 3.22 (95% CI 2.74-3.77, p < 0.00001); and that of long ablation duration was 1.00 (95% CI 0.98-1.02, p = 0.72). Heterogeneity and slight publication bias were observed for each factor.
Conclusions: Evidence indicates that diabetes, low left ventricular ejection fraction, being female, older age, longer duration of atrial fibrillation, elevated high-sensitivity C-reactive protein levels, large left atrial dimension, large left atrial volume index, persistent atrial fibrillation, and exercise rehabilitation are factors that increase the chances of getting atrial fibrillation again after catheter ablation. However, the length of the ablation procedure does not relate to the recurrence of AF.
背景:心房颤动(房颤)患者在导管消融术后症状复发率很高,其中涉及多种风险因素。本研究旨在进行一项荟萃分析,探讨与导管消融术后房颤患者复发有关的风险因素:方法:检索PubMed、Cochrane Library、WOS、Embase、SinoMed、CNKI、万方和VIP数据库中2000年1月1日至2021年8月10日的研究,选择符合既定纳入要求的研究。两位作者分别收集了有关研究结构的详细信息。使用几率比来评估各种风险因素与 CA 后房颤复发之间的联系强度。所有统计评估均使用RevMan5.3软件进行:共纳入 44 篇文章和 62,674 名患者。与参照组相比,糖尿病患者房颤复发的 OR 值为 2.04(95% CI 1.51-2.76,P 结论:有证据表明,糖尿病、低血压、心肌梗死和心律失常是房颤复发的主要原因:有证据表明,糖尿病、左室射血分数低、女性、年龄大、心房颤动持续时间长、高敏C反应蛋白水平升高、左心房尺寸大、左心房容积指数大、持续性心房颤动和运动康复是增加导管消融术后再次发生心房颤动几率的因素。然而,消融过程的长短与房颤复发无关。