The Use of MiniMed780G System Is Associated With Stable Glycemic Control in People With Type 1 Diabetes Before, During, and After Ramadan: An Observational Study.

IF 3.6 3区 医学 Q2 ENDOCRINOLOGY & METABOLISM
Journal of Diabetes Research Pub Date : 2025-01-02 eCollection Date: 2025-01-01 DOI:10.1155/jdr/4144787
Abdullah M Alguwaihes, Najla Alotaibi, Metib Alotaibi, Naglaa Masry, Saher Safarini
{"title":"The Use of MiniMed780G System Is Associated With Stable Glycemic Control in People With Type 1 Diabetes Before, During, and After Ramadan: An Observational Study.","authors":"Abdullah M Alguwaihes, Najla Alotaibi, Metib Alotaibi, Naglaa Masry, Saher Safarini","doi":"10.1155/jdr/4144787","DOIUrl":null,"url":null,"abstract":"<p><p><b>Aims:</b> The study was aimed at assessing the role of the MiniMed780G system of glycemic control before, during, and after Ramadan among people with Type 1 diabetes (PwT1D). <b>Methods:</b> This is a single-center retrospective analysis of MiniMed780G system users aged 14 years and above whose glycemic profiles were collected from February 21 to May 20, 2023, which corresponds to the Hijri months of Sha'ban, Ramadan, and Shawwal 1444/1445. Data was collected, processed, and analyzed in the framework of the Medtronic Galaxy service of the One Hospital Clinical Service (OHCS) program in Dallah Hospital, Riyadh, Saudi Arabia. Data from 43 PwT1D (24 females, mean age 30 ± 11 years with 14 ± 8 years from diabetes onset) using the MiniMed780G system were collected. <b>Results:</b> Overall, the 3-month (Sha'ban, Ramadan, and Shawwal) mean sensor glucose (SG), time in range (TIR) (70-180 mg/dL), time below range (TBR) (54-69 mg/dL and < 54 mg/dL), time above range (TAR) (180-250 mg/dL and > 250 mg/dL), and glucose management indicator (GMI) showed no statistical differences within the three periods. No differences in insulin total daily dose have been detected, and no diabetic ketoacidosis (DKA) or severe hypoglycemia events occurred. <b>Conclusion:</b> The use of the MiniMed780G system is safe with favorable glycemic outcomes across nonfasting and fasting months.</p>","PeriodicalId":15576,"journal":{"name":"Journal of Diabetes Research","volume":"2025 ","pages":"4144787"},"PeriodicalIF":3.6000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11717436/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Diabetes Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/jdr/4144787","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: The study was aimed at assessing the role of the MiniMed780G system of glycemic control before, during, and after Ramadan among people with Type 1 diabetes (PwT1D). Methods: This is a single-center retrospective analysis of MiniMed780G system users aged 14 years and above whose glycemic profiles were collected from February 21 to May 20, 2023, which corresponds to the Hijri months of Sha'ban, Ramadan, and Shawwal 1444/1445. Data was collected, processed, and analyzed in the framework of the Medtronic Galaxy service of the One Hospital Clinical Service (OHCS) program in Dallah Hospital, Riyadh, Saudi Arabia. Data from 43 PwT1D (24 females, mean age 30 ± 11 years with 14 ± 8 years from diabetes onset) using the MiniMed780G system were collected. Results: Overall, the 3-month (Sha'ban, Ramadan, and Shawwal) mean sensor glucose (SG), time in range (TIR) (70-180 mg/dL), time below range (TBR) (54-69 mg/dL and < 54 mg/dL), time above range (TAR) (180-250 mg/dL and > 250 mg/dL), and glucose management indicator (GMI) showed no statistical differences within the three periods. No differences in insulin total daily dose have been detected, and no diabetic ketoacidosis (DKA) or severe hypoglycemia events occurred. Conclusion: The use of the MiniMed780G system is safe with favorable glycemic outcomes across nonfasting and fasting months.

使用MiniMed780G系统与1型糖尿病患者斋月前后稳定血糖控制相关:一项观察性研究
目的:该研究旨在评估MiniMed780G系统在1型糖尿病(PwT1D)患者斋月前、期间和之后的血糖控制作用。方法:对2023年2月21日至5月20日收集的14岁及以上的MiniMed780G系统用户进行单中心回顾性分析,这些用户的血糖记录对应于斋月、斋月和斋月1444/1445。在沙特阿拉伯利雅得Dallah医院的一家医院临床服务(OHCS)项目的美敦力银河服务框架内收集、处理和分析数据。使用MiniMed780G系统收集了43例PwT1D患者(24例女性,平均年龄30±11岁,糖尿病发病时间14±8年)的数据。结果:总体而言,3个月(沙班、斋月和斋月)的平均传感器血糖(SG)、范围时间(TIR) (70-180 mg/dL)、范围下时间(TBR) (54-69 mg/dL和250 mg/dL)和葡萄糖管理指标(GMI)在3个时期内无统计学差异。胰岛素每日总剂量无差异,未发生糖尿病酮症酸中毒(DKA)或严重低血糖事件。结论:MiniMed780G系统的使用是安全的,在非禁食和禁食月份均有良好的血糖结局。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Diabetes Research
Journal of Diabetes Research ENDOCRINOLOGY & METABOLISM-MEDICINE, RESEARCH & EXPERIMENTAL
CiteScore
8.40
自引率
2.30%
发文量
152
审稿时长
14 weeks
期刊介绍: Journal of Diabetes Research is a peer-reviewed, Open Access journal that publishes research articles, review articles, and clinical studies related to type 1 and type 2 diabetes. The journal welcomes submissions focusing on the epidemiology, etiology, pathogenesis, management, and prevention of diabetes, as well as associated complications, such as diabetic retinopathy, neuropathy and nephropathy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信