A new stability indicating HPLC method with QDa and PDA detectors for the determination of process and degradation impurities of ivabradine including separation of diastereomeric N-oxides.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Büşra Gülşen, Sıdıka Ertürk Toker
{"title":"A new stability indicating HPLC method with QDa and PDA detectors for the determination of process and degradation impurities of ivabradine including separation of diastereomeric <i>N</i>-oxides.","authors":"Büşra Gülşen, Sıdıka Ertürk Toker","doi":"10.1039/d4ay01986e","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, a new reversed phase high performance liquid chromatography method using two detectors was developed for the analysis of degradation and process impurities of ivabradine in pharmaceutical preparations. A PDA detector set to 285 nm wavelength and a QDa detector set to positive scan mode were used in the method. In the developed method, the separation process was carried out in a Zorbax phenyl column with a gradient application of a 0.075% trifluoroacetic acid, acetonitrile, and methanol mixture at a flow rate of 1.5 ml min<sup>-1</sup>. During the degradation studies, the samples were exposed to acidic, alkaline, oxidative, thermal, and photolytic conditions. Process-related impurities were separated not only without interfering with each other but also with the degradation product and ivabradine peaks, and thanks to QDa, all impurities could be identified with their molecular weights. This method, in addition to providing stability data, was also able to separate two diastereomeric <i>N</i>-oxide impurities which are major oxidative degradation impurities of ivabradine having a chiral center. Some additional measurements such as solubility, specific rotation, melting point and differential scanning calorimetry analysis proved the formation of the two diastereomeric <i>N</i>-oxide impurities under oxidative conditions. Method validation was performed according to the International Council for Harmonization guidelines and the analysis of ivabradine, its process related impurities (dehydro ivabradine, acetyl ivabradine, and hydroxy ivabradine) and a major oxidative degradation product (ivabradine <i>N</i>-oxide) was successfully performed by this method.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01986e","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a new reversed phase high performance liquid chromatography method using two detectors was developed for the analysis of degradation and process impurities of ivabradine in pharmaceutical preparations. A PDA detector set to 285 nm wavelength and a QDa detector set to positive scan mode were used in the method. In the developed method, the separation process was carried out in a Zorbax phenyl column with a gradient application of a 0.075% trifluoroacetic acid, acetonitrile, and methanol mixture at a flow rate of 1.5 ml min-1. During the degradation studies, the samples were exposed to acidic, alkaline, oxidative, thermal, and photolytic conditions. Process-related impurities were separated not only without interfering with each other but also with the degradation product and ivabradine peaks, and thanks to QDa, all impurities could be identified with their molecular weights. This method, in addition to providing stability data, was also able to separate two diastereomeric N-oxide impurities which are major oxidative degradation impurities of ivabradine having a chiral center. Some additional measurements such as solubility, specific rotation, melting point and differential scanning calorimetry analysis proved the formation of the two diastereomeric N-oxide impurities under oxidative conditions. Method validation was performed according to the International Council for Harmonization guidelines and the analysis of ivabradine, its process related impurities (dehydro ivabradine, acetyl ivabradine, and hydroxy ivabradine) and a major oxidative degradation product (ivabradine N-oxide) was successfully performed by this method.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信