Effectiveness of Different Organic Solvent Additions to Water Samples for Reducing the Adsorption Effects of Organic Pesticides Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry.

IF 4.2 2区 化学 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Yucan Liu, Xinyi Xu, Ying Wang, Yan Zhang, Jianbo Lu, Chengbin Liu, Jinming Duan, Hongwei Sun
{"title":"Effectiveness of Different Organic Solvent Additions to Water Samples for Reducing the Adsorption Effects of Organic Pesticides Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry.","authors":"Yucan Liu, Xinyi Xu, Ying Wang, Yan Zhang, Jianbo Lu, Chengbin Liu, Jinming Duan, Hongwei Sun","doi":"10.3390/molecules30010200","DOIUrl":null,"url":null,"abstract":"<p><p>This study systematically investigated the effect of organic solvent addition on the detection signal intensity of 15 organic pesticides in water using ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS). The analysis of chromatographic peak area ratios in ultrapure water (UPW) versus 30% methanol (MeOH)-UPW showed that the adsorption effects (AEs, mainly from injection vials with weaker polarity) were the main factor influencing the detection intensity of the organic pesticides. The AEs varied with pesticide type and concentration, especially for those with high logK<sub>ow</sub> values and longer retention times, such as malathion, triadimefon, prometryn, S-metolachlor, diazinon, and profenofos. Significant differences were observed in the ability of five organic solvents (MeOH, dimethyl sulfoxide, isopropanol, acetonitrile, and acetone) to reduce AEs, with MeOH being the most effective. Optimal solvent ratios were determined to minimize AEs in aqueous solutions. Additionally, plastic injection vials caused greater AEs than glass injection vials, but the addition of organic solvents increased the detection intensity of the analytes for vials of both materials. Density functional theory calculations of the binding energies between pesticides (diazinon, malathion, and S-metolachlor) and vial materials further confirmed the effect of AE on the detection intensity of the analytes. This study showed that the addition of MeOH to real water samples effectively reduced or eliminated the effects of AEs, achieving a good linearity of calibration curves (0.05/0.1-5 μg/L, R<sup>2</sup> = 0.9853-0.9998), high sensitivity (LOD = 5-32 ng/L), precision (RSD = 1.4-14.5%), and accuracy (average recoveries = 80.6-121.8%). These results provide technical and methodological support for mitigating the effects of AEs on pesticide detection in water using UHPLC-ESI-MS/MS.</p>","PeriodicalId":19041,"journal":{"name":"Molecules","volume":"30 1","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11722058/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecules","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3390/molecules30010200","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study systematically investigated the effect of organic solvent addition on the detection signal intensity of 15 organic pesticides in water using ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS). The analysis of chromatographic peak area ratios in ultrapure water (UPW) versus 30% methanol (MeOH)-UPW showed that the adsorption effects (AEs, mainly from injection vials with weaker polarity) were the main factor influencing the detection intensity of the organic pesticides. The AEs varied with pesticide type and concentration, especially for those with high logKow values and longer retention times, such as malathion, triadimefon, prometryn, S-metolachlor, diazinon, and profenofos. Significant differences were observed in the ability of five organic solvents (MeOH, dimethyl sulfoxide, isopropanol, acetonitrile, and acetone) to reduce AEs, with MeOH being the most effective. Optimal solvent ratios were determined to minimize AEs in aqueous solutions. Additionally, plastic injection vials caused greater AEs than glass injection vials, but the addition of organic solvents increased the detection intensity of the analytes for vials of both materials. Density functional theory calculations of the binding energies between pesticides (diazinon, malathion, and S-metolachlor) and vial materials further confirmed the effect of AE on the detection intensity of the analytes. This study showed that the addition of MeOH to real water samples effectively reduced or eliminated the effects of AEs, achieving a good linearity of calibration curves (0.05/0.1-5 μg/L, R2 = 0.9853-0.9998), high sensitivity (LOD = 5-32 ng/L), precision (RSD = 1.4-14.5%), and accuracy (average recoveries = 80.6-121.8%). These results provide technical and methodological support for mitigating the effects of AEs on pesticide detection in water using UHPLC-ESI-MS/MS.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Molecules
Molecules 化学-有机化学
CiteScore
7.40
自引率
8.70%
发文量
7524
审稿时长
1.4 months
期刊介绍: Molecules (ISSN 1420-3049, CODEN: MOLEFW) is an open access journal of synthetic organic chemistry and natural product chemistry. All articles are peer-reviewed and published continously upon acceptance. Molecules is published by MDPI, Basel, Switzerland. Our aim is to encourage chemists to publish as much as possible their experimental detail, particularly synthetic procedures and characterization information. There is no restriction on the length of the experimental section. In addition, availability of compound samples is published and considered as important information. Authors are encouraged to register or deposit their chemical samples through the non-profit international organization Molecular Diversity Preservation International (MDPI). Molecules has been launched in 1996 to preserve and exploit molecular diversity of both, chemical information and chemical substances.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信