Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.

IF 2.6 Q2 HEALTH CARE SCIENCES & SERVICES
JMIR Human Factors Pub Date : 2025-01-07 DOI:10.2196/65578
Fu-Yu Chen, Tzu-Yao Lin, Yi-Cheng Huang, Evina Widianawati
{"title":"Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.","authors":"Fu-Yu Chen, Tzu-Yao Lin, Yi-Cheng Huang, Evina Widianawati","doi":"10.2196/65578","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Muscle fatigue, characterized by reduced force generation during repetitive contractions, impacts older adults doing daily activities and athletes during sports activities. While various sensors detect muscle fatigue via muscle activity, biochemical markers, and kinematic parameters, a real-time wearable solution with high usability remains limited. Plantar pressure monitoring detects muscle fatigue through foot loading changes, seamlessly integrating into footwear to improve the usability and compliance for home-based monitoring.</p><p><strong>Objective: </strong>This study aimed to investigate the effects of muscle fatigue on plantar pressure measurements using a self-developed wearable plantar pressure system.</p><p><strong>Methods: </strong>Twelve healthy participants completed a 5-minute calf muscle fatigue protocol. The plantar pressures and surface electromyography (sEMG) activity of the gastrocnemius muscles were recorded before and after exercise. The plantar pressures at 6 regions and the median frequency (MDF) of sEMG were analyzed to quantify fatigue.</p><p><strong>Results: </strong>The self-developed foot pressure system showed a significant decrease in plantar pressure peak values at the heel of the left (P=.003) and right feet (P=.001) and at the lateral toe of the left (P=.001) and right feet (P=.026). A significant increase was observed at the metatarsal head of both the left foot (P=.001) and the right foot (P=.017). The MDF of sEMG signals significantly decreased in the left (P=.001) and right gastrocnemius (P<.001).</p><p><strong>Conclusions: </strong>Plantar pressure changes and sEMG signals effectively detect gastrocnemius muscle fatigue using the proposed wearable system, supporting the development of a wearable solution for detecting muscle fatigue suitable for home-use.</p>","PeriodicalId":36351,"journal":{"name":"JMIR Human Factors","volume":"12 ","pages":"e65578"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11731697/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Human Factors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/65578","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Muscle fatigue, characterized by reduced force generation during repetitive contractions, impacts older adults doing daily activities and athletes during sports activities. While various sensors detect muscle fatigue via muscle activity, biochemical markers, and kinematic parameters, a real-time wearable solution with high usability remains limited. Plantar pressure monitoring detects muscle fatigue through foot loading changes, seamlessly integrating into footwear to improve the usability and compliance for home-based monitoring.

Objective: This study aimed to investigate the effects of muscle fatigue on plantar pressure measurements using a self-developed wearable plantar pressure system.

Methods: Twelve healthy participants completed a 5-minute calf muscle fatigue protocol. The plantar pressures and surface electromyography (sEMG) activity of the gastrocnemius muscles were recorded before and after exercise. The plantar pressures at 6 regions and the median frequency (MDF) of sEMG were analyzed to quantify fatigue.

Results: The self-developed foot pressure system showed a significant decrease in plantar pressure peak values at the heel of the left (P=.003) and right feet (P=.001) and at the lateral toe of the left (P=.001) and right feet (P=.026). A significant increase was observed at the metatarsal head of both the left foot (P=.001) and the right foot (P=.017). The MDF of sEMG signals significantly decreased in the left (P=.001) and right gastrocnemius (P<.001).

Conclusions: Plantar pressure changes and sEMG signals effectively detect gastrocnemius muscle fatigue using the proposed wearable system, supporting the development of a wearable solution for detecting muscle fatigue suitable for home-use.

使用数字可穿戴足底压力装置检测肌肉疲劳的有效性:受试者内重复测量实验设计。
背景:肌肉疲劳,其特征是在重复收缩过程中产生的力减少,影响日常活动的老年人和体育运动中的运动员。虽然各种传感器通过肌肉活动、生化标记和运动学参数来检测肌肉疲劳,但具有高可用性的实时可穿戴解决方案仍然有限。足底压力监测通过脚负荷变化检测肌肉疲劳,无缝集成到鞋类,以提高家庭监测的可用性和合规性。目的:利用自行研制的可穿戴式足底压力测量系统,研究肌肉疲劳对足底压力测量的影响。方法:12名健康参与者完成了5分钟小腿肌肉疲劳方案。记录运动前后腓肠肌的足底压力和表面肌电活动。分析6个区域的足底压力和表面肌电信号的中位数频率(MDF)来量化疲劳。结果:自主开发的足压系统显示,左、右足跟部(P= 0.003)和左、右足外侧脚趾部(P= 0.001)的足底压力峰值显著降低(P= 0.026)。在左脚跖骨头(P=.001)和右脚跖骨头(P=.017)观察到显著增加。左侧腓肠肌肌电信号的MDF显著降低(P=.001),右侧腓肠肌肌电信号的MDF显著降低(P=.001)。结论:采用所提出的可穿戴系统,足底压力变化和sEMG信号可以有效检测腓肠肌疲劳,支持开发适合家庭使用的可穿戴肌肉疲劳检测解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Human Factors
JMIR Human Factors Medicine-Health Informatics
CiteScore
3.40
自引率
3.70%
发文量
123
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信