Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.

IF 2.6 Q2 HEALTH CARE SCIENCES & SERVICES
JMIR Human Factors Pub Date : 2025-01-07 DOI:10.2196/65578
Fu-Yu Chen, Tzu-Yao Lin, Yi-Cheng Huang, Evina Widianawati
{"title":"Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.","authors":"Fu-Yu Chen, Tzu-Yao Lin, Yi-Cheng Huang, Evina Widianawati","doi":"10.2196/65578","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Muscle fatigue, characterized by reduced force generation during repetitive contractions, impacts older adults doing daily activities and athletes during sports activities. While various sensors detect muscle fatigue via muscle activity, biochemical markers, and kinematic parameters, a real-time wearable solution with high usability remains limited. Plantar pressure monitoring detects muscle fatigue through foot loading changes, seamlessly integrating into footwear to improve the usability and compliance for home-based monitoring.</p><p><strong>Objective: </strong>This study aimed to investigate the effects of muscle fatigue on plantar pressure measurements using a self-developed wearable plantar pressure system.</p><p><strong>Methods: </strong>Twelve healthy participants completed a 5-minute calf muscle fatigue protocol. The plantar pressures and surface electromyography (sEMG) activity of the gastrocnemius muscles were recorded before and after exercise. The plantar pressures at 6 regions and the median frequency (MDF) of sEMG were analyzed to quantify fatigue.</p><p><strong>Results: </strong>The self-developed foot pressure system showed a significant decrease in plantar pressure peak values at the heel of the left (P=.003) and right feet (P=.001) and at the lateral toe of the left (P=.001) and right feet (P=.026). A significant increase was observed at the metatarsal head of both the left foot (P=.001) and the right foot (P=.017). The MDF of sEMG signals significantly decreased in the left (P=.001) and right gastrocnemius (P<.001).</p><p><strong>Conclusions: </strong>Plantar pressure changes and sEMG signals effectively detect gastrocnemius muscle fatigue using the proposed wearable system, supporting the development of a wearable solution for detecting muscle fatigue suitable for home-use.</p>","PeriodicalId":36351,"journal":{"name":"JMIR Human Factors","volume":"12 ","pages":"e65578"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Human Factors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/65578","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Muscle fatigue, characterized by reduced force generation during repetitive contractions, impacts older adults doing daily activities and athletes during sports activities. While various sensors detect muscle fatigue via muscle activity, biochemical markers, and kinematic parameters, a real-time wearable solution with high usability remains limited. Plantar pressure monitoring detects muscle fatigue through foot loading changes, seamlessly integrating into footwear to improve the usability and compliance for home-based monitoring.

Objective: This study aimed to investigate the effects of muscle fatigue on plantar pressure measurements using a self-developed wearable plantar pressure system.

Methods: Twelve healthy participants completed a 5-minute calf muscle fatigue protocol. The plantar pressures and surface electromyography (sEMG) activity of the gastrocnemius muscles were recorded before and after exercise. The plantar pressures at 6 regions and the median frequency (MDF) of sEMG were analyzed to quantify fatigue.

Results: The self-developed foot pressure system showed a significant decrease in plantar pressure peak values at the heel of the left (P=.003) and right feet (P=.001) and at the lateral toe of the left (P=.001) and right feet (P=.026). A significant increase was observed at the metatarsal head of both the left foot (P=.001) and the right foot (P=.017). The MDF of sEMG signals significantly decreased in the left (P=.001) and right gastrocnemius (P<.001).

Conclusions: Plantar pressure changes and sEMG signals effectively detect gastrocnemius muscle fatigue using the proposed wearable system, supporting the development of a wearable solution for detecting muscle fatigue suitable for home-use.

求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Human Factors
JMIR Human Factors Medicine-Health Informatics
CiteScore
3.40
自引率
3.70%
发文量
123
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信