Cheng-Hao Ko, Wei-Yi Kong, Abel Chernet Kabiso, Wei-Huai Chiu, Ashenafi Belihu Tadesse, Chitsung Hong, Chia-Fang Wu, Hung-Hsun Lin
{"title":"Portable SpectroChip-Based Immunoassay Platform for Rapid and Accurate Melamine Quantification in Urine Samples.","authors":"Cheng-Hao Ko, Wei-Yi Kong, Abel Chernet Kabiso, Wei-Huai Chiu, Ashenafi Belihu Tadesse, Chitsung Hong, Chia-Fang Wu, Hung-Hsun Lin","doi":"10.3390/toxics12120870","DOIUrl":null,"url":null,"abstract":"<p><p>Growing concerns about the health risks of melamine adulteration in food products highlight the urgent need for reliable detection methods. However, the long-term effects of chronic low-level melamine exposure remain inadequately explored. This study introduces THE ONE InstantCare platform, a portable immunoassay analyzer integrating a SpectroChip-based spectral processing unit (SPU) with lateral flow immunoassay (LFIA) for sensitive and accurate quantification of melamine in human urine. This platform provides a cost-effective, rapid, and user-friendly point-of-care (POC) solution for melamine detection. Analytical evaluations across eight melamine concentrations (0-100 parts per billion, ppb) achieved a limit of detection (LOD) of 1.91 ppb. Validation with 24 human urine samples demonstrated strong concordance with liquid chromatography-mass spectrometry (LC-MS), yielding an intraclass correlation coefficient (ICC) of 0.9220, a Pearson correlation coefficient of 0.9389, and 95% agreement in Bland-Altman analysis. High reproducibility was observed, with an intraday coefficient of variation (CV) of 6.53% and acceptable interday CV values, while interference studies confirmed reliability in the presence of common biological substances. By delivering results in approximately 10 min, THE ONE InstantCare platform significantly reduces analysis time compared to LC-MS, which typically requires several hours. This novel platform enhances food safety surveillance and advances human health risk assessments, particularly for evaluating melamine-linked kidney damage. Its versatility and robust performance make it a promising tool for environmental monitoring and clinical diagnostics, enabling the detection of diverse biomarkers with high sensitivity and reproducibility.</p>","PeriodicalId":23195,"journal":{"name":"Toxics","volume":"12 12","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11679044/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Toxics","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.3390/toxics12120870","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Growing concerns about the health risks of melamine adulteration in food products highlight the urgent need for reliable detection methods. However, the long-term effects of chronic low-level melamine exposure remain inadequately explored. This study introduces THE ONE InstantCare platform, a portable immunoassay analyzer integrating a SpectroChip-based spectral processing unit (SPU) with lateral flow immunoassay (LFIA) for sensitive and accurate quantification of melamine in human urine. This platform provides a cost-effective, rapid, and user-friendly point-of-care (POC) solution for melamine detection. Analytical evaluations across eight melamine concentrations (0-100 parts per billion, ppb) achieved a limit of detection (LOD) of 1.91 ppb. Validation with 24 human urine samples demonstrated strong concordance with liquid chromatography-mass spectrometry (LC-MS), yielding an intraclass correlation coefficient (ICC) of 0.9220, a Pearson correlation coefficient of 0.9389, and 95% agreement in Bland-Altman analysis. High reproducibility was observed, with an intraday coefficient of variation (CV) of 6.53% and acceptable interday CV values, while interference studies confirmed reliability in the presence of common biological substances. By delivering results in approximately 10 min, THE ONE InstantCare platform significantly reduces analysis time compared to LC-MS, which typically requires several hours. This novel platform enhances food safety surveillance and advances human health risk assessments, particularly for evaluating melamine-linked kidney damage. Its versatility and robust performance make it a promising tool for environmental monitoring and clinical diagnostics, enabling the detection of diverse biomarkers with high sensitivity and reproducibility.
ToxicsChemical Engineering-Chemical Health and Safety
CiteScore
4.50
自引率
10.90%
发文量
681
审稿时长
6 weeks
期刊介绍:
Toxics (ISSN 2305-6304) is an international, peer-reviewed, open access journal which provides an advanced forum for studies related to all aspects of toxic chemicals and materials. It publishes reviews, regular research papers, and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in detail. There is, therefore, no restriction on the maximum length of the papers, although authors should write their papers in a clear and concise way. The full experimental details must be provided so that the results can be reproduced. Electronic files or software regarding the full details of calculations and experimental procedure can be deposited as supplementary material, if it is not possible to publish them along with the text.