Development and Clinical Evaluation of a Contrast Optimizer for Contrast-Enhanced CT Imaging of the Liver.

IF 1 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Hananiel Setiawan, Francesco Ria, Ehsan Abadi, Daniele Marin, Lior Molvin, Ehsan Samei
{"title":"Development and Clinical Evaluation of a Contrast Optimizer for Contrast-Enhanced CT Imaging of the Liver.","authors":"Hananiel Setiawan, Francesco Ria, Ehsan Abadi, Daniele Marin, Lior Molvin, Ehsan Samei","doi":"10.1097/RCT.0000000000001677","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Patient characteristics, iodine injection, and scanning parameters can impact the quality and consistency of contrast enhancement of hepatic parenchyma in CT imaging. Improving the consistency and adequacy of contrast enhancement can enhance diagnostic accuracy and reduce clinical practice variability, with added positive implications for safety and cost-effectiveness in the use of contrast medium. We developed a clinical tool that uses patient attributes (height, weight, sex, age) to predict hepatic enhancement and suggest alternative injection/scanning parameters to optimize the procedure.</p><p><strong>Methods: </strong>The tool was based on a previously validated neural network prediction model that suggested adjustments for patients with predicted insufficient enhancement. We conducted a prospective clinical study in which we tested this tool in 24 patients aiming for a target portal-venous parenchyma CT number of 110 HU ± 10 HU.</p><p><strong>Results: </strong>Out of the 24 patients, 15 received adjustments to their iodine contrast injection parameters, resulting in median reductions of 8.8% in volume and 9.1% in injection rate. The scan delays were reduced by an average of 42.6%. We compared the results with the patients' previous scans and found that the tool improved consistency and reduced the number of underenhanced patients. The median enhancement remained relatively unchanged, but the number of underenhanced patients was reduced by half, and all previously overenhanced patients received enhancement reductions.</p><p><strong>Conclusions: </strong>Our study showed that the proposed patient-informed clinical framework can predict optimal contrast enhancement and suggest empiric injection/scanning parameters to achieve consistent and sufficient contrast enhancement of hepatic parenchyma. The described GUI-based tool can prospectively inform clinical decision-making predicting optimal patient's hepatic parenchyma contrast enhancement. This reduces instances of nondiagnostic/insufficient enhancement in patients.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001677","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Patient characteristics, iodine injection, and scanning parameters can impact the quality and consistency of contrast enhancement of hepatic parenchyma in CT imaging. Improving the consistency and adequacy of contrast enhancement can enhance diagnostic accuracy and reduce clinical practice variability, with added positive implications for safety and cost-effectiveness in the use of contrast medium. We developed a clinical tool that uses patient attributes (height, weight, sex, age) to predict hepatic enhancement and suggest alternative injection/scanning parameters to optimize the procedure.

Methods: The tool was based on a previously validated neural network prediction model that suggested adjustments for patients with predicted insufficient enhancement. We conducted a prospective clinical study in which we tested this tool in 24 patients aiming for a target portal-venous parenchyma CT number of 110 HU ± 10 HU.

Results: Out of the 24 patients, 15 received adjustments to their iodine contrast injection parameters, resulting in median reductions of 8.8% in volume and 9.1% in injection rate. The scan delays were reduced by an average of 42.6%. We compared the results with the patients' previous scans and found that the tool improved consistency and reduced the number of underenhanced patients. The median enhancement remained relatively unchanged, but the number of underenhanced patients was reduced by half, and all previously overenhanced patients received enhancement reductions.

Conclusions: Our study showed that the proposed patient-informed clinical framework can predict optimal contrast enhancement and suggest empiric injection/scanning parameters to achieve consistent and sufficient contrast enhancement of hepatic parenchyma. The described GUI-based tool can prospectively inform clinical decision-making predicting optimal patient's hepatic parenchyma contrast enhancement. This reduces instances of nondiagnostic/insufficient enhancement in patients.

肝脏CT增强成像造影剂的研制及临床评价。
目的:患者特征、碘注射液、扫描参数对肝实质CT增强质量和一致性有影响。提高造影剂增强的一致性和充分性可以提高诊断的准确性,减少临床实践的可变性,对造影剂使用的安全性和成本效益具有积极意义。我们开发了一种临床工具,该工具使用患者属性(身高、体重、性别、年龄)来预测肝脏增强,并建议替代注射/扫描参数以优化程序。方法:该工具基于先前验证的神经网络预测模型,该模型建议对预测增强不足的患者进行调整。我们进行了一项前瞻性临床研究,在24例患者中测试了该工具,目标门静脉实质CT值为110 HU±10 HU。结果:在24例患者中,15例接受了碘造影剂注射参数的调整,导致中位体积减少8.8%,注射速度减少9.1%。扫描延迟平均减少了42.6%。我们将结果与患者之前的扫描结果进行了比较,发现该工具提高了一致性并减少了未增强患者的数量。中位增强保持相对不变,但增强不足的患者数量减少了一半,所有先前过度增强的患者都接受了增强减少。结论:我们的研究表明,提出的患者知情的临床框架可以预测最佳的造影剂增强,并建议经验注射/扫描参数,以实现一致和充分的肝实质造影剂增强。所描述的基于gui的工具可以前瞻性地为临床决策提供信息,预测最佳患者肝实质增强。这减少了患者的非诊断性/不充分增强的情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
230
审稿时长
4-8 weeks
期刊介绍: The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信