Classification of arteriovenous fistula sounds using a convolutional block attention module and long short-term memory neural network.

IF 3.2 3区 医学 Q2 PHYSIOLOGY
Frontiers in Physiology Pub Date : 2024-12-24 eCollection Date: 2024-01-01 DOI:10.3389/fphys.2024.1397317
Jun Zhang, Rongxi Zhang, Xinming Shu, Hongtao Zhang
{"title":"Classification of arteriovenous fistula sounds using a convolutional block attention module and long short-term memory neural network.","authors":"Jun Zhang, Rongxi Zhang, Xinming Shu, Hongtao Zhang","doi":"10.3389/fphys.2024.1397317","DOIUrl":null,"url":null,"abstract":"<p><p>The assessment of vascular accessibility in patients undergoing hemodialysis is predominantly reliant on manual inspection, a method that is associated with several limitations. In this study, we propose an alternative approach by recording the acoustic signals produced by the arteriovenous fistula (AVF) and employing deep learning techniques to analyze these sounds as an objective complement to traditional AVF evaluation methods. Auscultation sounds were collected from 800 patients, with each recording lasting between 24 and 30 s. Features were extracted by combining Mel-Frequency Cepstral Coefficients with Mel-Spectrogram data, generating a novel set of feature parameters. These parameters were subsequently used as input to a model that integrates the Convolutional Block Attention Module and a Long Short-Term Memory neural network, designed to classify the severity of AVF stenosis based on two sound categories (normal and abnormal). The experimental results demonstrate that the CBAM-LSTM model achieves an Area Under the Receiver Operating Characteristic curve of 99%, Precision of 99%, Recall of 97%, and F1 Score of 98%. Comparative analysis with other models, including VGG, Bi-LSTM, DenseNet121, and ResNet50, indicates that the proposed CBAM-LSTM model outperforms these alternatives in classifying AVF stenosis severity. These findings suggest the potential of the CBAM-LSTM model as a reliable tool for monitoring AVF maturation.</p>","PeriodicalId":12477,"journal":{"name":"Frontiers in Physiology","volume":"15 ","pages":"1397317"},"PeriodicalIF":3.2000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11703813/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/fphys.2024.1397317","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The assessment of vascular accessibility in patients undergoing hemodialysis is predominantly reliant on manual inspection, a method that is associated with several limitations. In this study, we propose an alternative approach by recording the acoustic signals produced by the arteriovenous fistula (AVF) and employing deep learning techniques to analyze these sounds as an objective complement to traditional AVF evaluation methods. Auscultation sounds were collected from 800 patients, with each recording lasting between 24 and 30 s. Features were extracted by combining Mel-Frequency Cepstral Coefficients with Mel-Spectrogram data, generating a novel set of feature parameters. These parameters were subsequently used as input to a model that integrates the Convolutional Block Attention Module and a Long Short-Term Memory neural network, designed to classify the severity of AVF stenosis based on two sound categories (normal and abnormal). The experimental results demonstrate that the CBAM-LSTM model achieves an Area Under the Receiver Operating Characteristic curve of 99%, Precision of 99%, Recall of 97%, and F1 Score of 98%. Comparative analysis with other models, including VGG, Bi-LSTM, DenseNet121, and ResNet50, indicates that the proposed CBAM-LSTM model outperforms these alternatives in classifying AVF stenosis severity. These findings suggest the potential of the CBAM-LSTM model as a reliable tool for monitoring AVF maturation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
5.00%
发文量
2608
审稿时长
14 weeks
期刊介绍: Frontiers in Physiology is a leading journal in its field, publishing rigorously peer-reviewed research on the physiology of living systems, from the subcellular and molecular domains to the intact organism, and its interaction with the environment. Field Chief Editor George E. Billman at the Ohio State University Columbus is supported by an outstanding Editorial Board of international researchers. This multidisciplinary open-access journal is at the forefront of disseminating and communicating scientific knowledge and impactful discoveries to researchers, academics, clinicians and the public worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信