Transcranial electrical evoked muscle potentials for pediatric neurosurgery: scoping review of stimulation techniques and success rates.

IF 1.3 4区 医学 Q4 CLINICAL NEUROLOGY
Axel Fudickar, Kai Berndt, Klaus Novak
{"title":"Transcranial electrical evoked muscle potentials for pediatric neurosurgery: scoping review of stimulation techniques and success rates.","authors":"Axel Fudickar, Kai Berndt, Klaus Novak","doi":"10.1007/s00381-024-06739-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The background of this scoping review is that pediatric neurosurgery in the vicinity of motor pathways is associated with the risk of motor tract damage. By measuring transcranial electrical evoked potentials in muscles (electromyogram) or from the spinal cord (epidural D-wave) functional disorders and impending damage can be detected during surgery and countermeasures can be initiated. The objective was to summarize stimulation techniques of transcranial electrical stimulation and the success rate of motor evoked potentials exclusively in children undergoing neurosurgery.</p><p><strong>Methods: </strong>The data source was a literature search for reports meeting the suitability criteria (original articles and case series including motor evoked potentials and pediatric neurosurgery).</p><p><strong>Results: </strong>Twenty-four articles meeting suitability criteria were retrieved. The most common primary electrode positions for electrical stimulation were at C3 vs. C4 and C1 vs. C2 according to the 10-20-system of EEG. Single trains of 1 to 9 pulses with voltages from 160 to 900 V and pulse durations from 50 to 500 µs were applied for voltage-controlled stimulation. Interstimulus intervals ranged from 0.1 to 9.9 ms. Signals were filtered with high-pass filters between 1.5 and 300 Hz and low-pass filters between 500 and 5000 Hz. The overall rate of successful stimulation and measurement was 90.5% (N = 769).</p><p><strong>Conclusion: </strong>A broad range of stimulation parameters was used for transcranial electrical evoked potentials. Measurable potentials were obtained in most patients. Consideration of safety precautions is an important implication to avoid adverse events by application of high voltage to the motor cortex.</p>","PeriodicalId":9970,"journal":{"name":"Child's Nervous System","volume":"41 1","pages":"88"},"PeriodicalIF":1.3000,"publicationDate":"2025-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Child's Nervous System","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00381-024-06739-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The background of this scoping review is that pediatric neurosurgery in the vicinity of motor pathways is associated with the risk of motor tract damage. By measuring transcranial electrical evoked potentials in muscles (electromyogram) or from the spinal cord (epidural D-wave) functional disorders and impending damage can be detected during surgery and countermeasures can be initiated. The objective was to summarize stimulation techniques of transcranial electrical stimulation and the success rate of motor evoked potentials exclusively in children undergoing neurosurgery.

Methods: The data source was a literature search for reports meeting the suitability criteria (original articles and case series including motor evoked potentials and pediatric neurosurgery).

Results: Twenty-four articles meeting suitability criteria were retrieved. The most common primary electrode positions for electrical stimulation were at C3 vs. C4 and C1 vs. C2 according to the 10-20-system of EEG. Single trains of 1 to 9 pulses with voltages from 160 to 900 V and pulse durations from 50 to 500 µs were applied for voltage-controlled stimulation. Interstimulus intervals ranged from 0.1 to 9.9 ms. Signals were filtered with high-pass filters between 1.5 and 300 Hz and low-pass filters between 500 and 5000 Hz. The overall rate of successful stimulation and measurement was 90.5% (N = 769).

Conclusion: A broad range of stimulation parameters was used for transcranial electrical evoked potentials. Measurable potentials were obtained in most patients. Consideration of safety precautions is an important implication to avoid adverse events by application of high voltage to the motor cortex.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Child's Nervous System
Child's Nervous System 医学-临床神经学
CiteScore
3.00
自引率
7.10%
发文量
322
审稿时长
3 months
期刊介绍: The journal has been expanded to encompass all aspects of pediatric neurosciences concerning the developmental and acquired abnormalities of the nervous system and its coverings, functional disorders, epilepsy, spasticity, basic and clinical neuro-oncology, rehabilitation and trauma. Global pediatric neurosurgery is an additional field of interest that will be considered for publication in the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信