Application of multifunctional pulse wave sphygmomanometer combined with constant temperature ice in patients with forearm hematoma after coronary intervention.

IF 2 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Jimin Qiao, Yihang Shi, Kai Li, Xiaomin Zhu, Zhimei Wang
{"title":"Application of multifunctional pulse wave sphygmomanometer combined with constant temperature ice in patients with forearm hematoma after coronary intervention.","authors":"Jimin Qiao, Yihang Shi, Kai Li, Xiaomin Zhu, Zhimei Wang","doi":"10.1186/s12872-024-04432-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study aims to investigate the effects of combining a multifunctional pulse wave sphygmomanometer with constant temperature ice on patients with forearm hematoma following coronary intervention.</p><p><strong>Methods: </strong>Patients who developed forearm hematoma after undergoing coronary intervention from March 2021 to March 2023 at our hospital were selected as the study cohort. Using a random number table, they were divided into two groups the control group and the research group. The control group received cuff compression treatment using a multifunctional pulse wave sphygmomanometer. The primary endpoint was the effective rate of one compression. Secondary endpoints included body surface temperature, pain, comfort, arm measurements, and swelling value.</p><p><strong>Results: </strong>A total of 190 patients were included, with 95 in the control group and 95 in the research group. The research group showed a significantly higher effective rate of one compression compared to the control group (87.2% vs. 95.8%, p = 0.035). Additionally, the research group experienced significantly reduced pain (2.0 [2.0,3.0] vs. 1.0 [1.0,2.0], p < 0.001) and improved comfort levels. This approach also effectively reduced body surface temperature (32.91 ± 0.83℃ vs. 12.09 ± 1.09℃, p < 0.001), arm measurements (274.32 ± 9.56 mm vs. 271.15 ± 8.82 mm, p = 0.019), and swelling value (12.40 ± 1.95 vs. 11.07 ± 2.13, p < 0.001) after compression.</p><p><strong>Conclusions: </strong>The combined use of a multifunctional pulse wave sphygmomanometer for cuff compression on forearm hematoma with simultaneous constant temperature ice application demonstrated more benefits. This approach effectively reduced pain, improved comfort levels, and enhanced compression-based hemostasis and reduction of swelling.</p><p><strong>Trial registration: </strong>Ethics No.KY20210604-02-KS-01.</p>","PeriodicalId":9195,"journal":{"name":"BMC Cardiovascular Disorders","volume":"25 1","pages":"8"},"PeriodicalIF":2.0000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11706164/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Cardiovascular Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12872-024-04432-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study aims to investigate the effects of combining a multifunctional pulse wave sphygmomanometer with constant temperature ice on patients with forearm hematoma following coronary intervention.

Methods: Patients who developed forearm hematoma after undergoing coronary intervention from March 2021 to March 2023 at our hospital were selected as the study cohort. Using a random number table, they were divided into two groups the control group and the research group. The control group received cuff compression treatment using a multifunctional pulse wave sphygmomanometer. The primary endpoint was the effective rate of one compression. Secondary endpoints included body surface temperature, pain, comfort, arm measurements, and swelling value.

Results: A total of 190 patients were included, with 95 in the control group and 95 in the research group. The research group showed a significantly higher effective rate of one compression compared to the control group (87.2% vs. 95.8%, p = 0.035). Additionally, the research group experienced significantly reduced pain (2.0 [2.0,3.0] vs. 1.0 [1.0,2.0], p < 0.001) and improved comfort levels. This approach also effectively reduced body surface temperature (32.91 ± 0.83℃ vs. 12.09 ± 1.09℃, p < 0.001), arm measurements (274.32 ± 9.56 mm vs. 271.15 ± 8.82 mm, p = 0.019), and swelling value (12.40 ± 1.95 vs. 11.07 ± 2.13, p < 0.001) after compression.

Conclusions: The combined use of a multifunctional pulse wave sphygmomanometer for cuff compression on forearm hematoma with simultaneous constant temperature ice application demonstrated more benefits. This approach effectively reduced pain, improved comfort levels, and enhanced compression-based hemostasis and reduction of swelling.

Trial registration: Ethics No.KY20210604-02-KS-01.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Cardiovascular Disorders
BMC Cardiovascular Disorders CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.50
自引率
0.00%
发文量
480
审稿时长
1 months
期刊介绍: BMC Cardiovascular Disorders is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the heart and circulatory system, as well as related molecular and cell biology, genetics, pathophysiology, epidemiology, and controlled trials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信