Commutability assessment of new standard reference materials (SRMs) for determining serum total 25-hydroxyvitamin D using ligand binding and liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays.

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Stephen A Wise, Étienne Cavalier, Pierre Lukas, Stéphanie Peeters, Caroline Le Goff, Laura E Briggs, Emma L Williams, Ekaterina Mineva, Christine M Pfeiffer, Hubert Vesper, Christian Popp, Christian Beckert, Jan Schultess, Kevin Wang, Carole Tourneur, Camille Pease, Dominik Osterritter, Ralf Fischer, Ben Saida, Chao Dou, Satoshi Kojima, Hope A Weiler, Agnieszka Bielecki, Heather Pham, Alexandra Bennett, Shawn You, Amit K Ghoshal, Bin Wei, Christian Vogl, James Freeman, Neil Parker, Samantha Pagliaro, Jennifer Cheek, Jie Li, Hisao Tsukamoto, Karen Galvin, Kevin D Cashman, Hsuan-Chieh Liao, Andrew N Hoofnagle, Jeffery R Budd, Adam J Kuszak, Ashley S P Boggs, Carolyn Q Burdette, Grace Hahm, Federica Nalin, Johanna E Camara
{"title":"Commutability assessment of new standard reference materials (SRMs) for determining serum total 25-hydroxyvitamin D using ligand binding and liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays.","authors":"Stephen A Wise, Étienne Cavalier, Pierre Lukas, Stéphanie Peeters, Caroline Le Goff, Laura E Briggs, Emma L Williams, Ekaterina Mineva, Christine M Pfeiffer, Hubert Vesper, Christian Popp, Christian Beckert, Jan Schultess, Kevin Wang, Carole Tourneur, Camille Pease, Dominik Osterritter, Ralf Fischer, Ben Saida, Chao Dou, Satoshi Kojima, Hope A Weiler, Agnieszka Bielecki, Heather Pham, Alexandra Bennett, Shawn You, Amit K Ghoshal, Bin Wei, Christian Vogl, James Freeman, Neil Parker, Samantha Pagliaro, Jennifer Cheek, Jie Li, Hisao Tsukamoto, Karen Galvin, Kevin D Cashman, Hsuan-Chieh Liao, Andrew N Hoofnagle, Jeffery R Budd, Adam J Kuszak, Ashley S P Boggs, Carolyn Q Burdette, Grace Hahm, Federica Nalin, Johanna E Camara","doi":"10.1007/s00216-024-05699-7","DOIUrl":null,"url":null,"abstract":"<p><p>Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials<sup>®</sup> (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D<sub>2</sub> [25(OH)D<sub>2</sub>] and 25-hydroxyvitamin D<sub>3</sub> [25(OH)D<sub>3</sub>], was assessed through an interlaboratory study. The following SRMs were assessed: (1) SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level), (2) SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D<sub>2</sub> High Level), and (3) SRM 1949 Frozen Human Prenatal Serum. These SRMs represent three clinically relevant situations including (1) low levels of total 25(OH)D, (2) high level of 25(OH)D<sub>2</sub>, and (3) 25(OH)D levels in nonpregnant women and women during each of the three trimesters of pregnancy with changing concentrations of vitamin D-binding protein (VDBP). Twelve laboratories using 17 different ligand binding assays and eight laboratories using nine commercial and custom liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays provided results in this study. Commutability of the SRMs with patient samples was assessed using the Clinical and Laboratory Standards Institute (CLSI) approach based on 95% prediction intervals or a pre-set commutability criterion and the recently introduced International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approach based on differences in bias for the clinical and reference material samples using a commutability criterion of 8.8%. All three SRMs were deemed as commutable with all LC-MS/MS assays using both CLSI and IFCC approaches. SRM 2969 and SRM 2970 were deemed noncommutable for three and seven different ligand binding assays, respectively, when using the IFCC approach. Except for two assays, one or more of the three pregnancy levels of SRM 1949 were deemed noncommutable or inconclusive using different ligand binding assays and the commutability criterion of 8.8%. Overall, a noncommutable assessment for ligand binding assays is determined for these SRMs primarily due to a lack of assay selectivity related to 25(OH)D<sub>2</sub> or an increasing VDBP in pregnancy trimester materials rather than the quality of the SRMs. With results from 17 different ligand binding and nine LC-MS/MS assays, this study provides valuable knowledge for clinical laboratories to inform SRM selection when assessing 25(OH)D status in patient populations, particularly in subpopulations with low levels of 25(OH)D, high levels of 25(OH)D<sub>2</sub>, women only, or women who are pregnant.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05699-7","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials® (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], was assessed through an interlaboratory study. The following SRMs were assessed: (1) SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level), (2) SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D2 High Level), and (3) SRM 1949 Frozen Human Prenatal Serum. These SRMs represent three clinically relevant situations including (1) low levels of total 25(OH)D, (2) high level of 25(OH)D2, and (3) 25(OH)D levels in nonpregnant women and women during each of the three trimesters of pregnancy with changing concentrations of vitamin D-binding protein (VDBP). Twelve laboratories using 17 different ligand binding assays and eight laboratories using nine commercial and custom liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays provided results in this study. Commutability of the SRMs with patient samples was assessed using the Clinical and Laboratory Standards Institute (CLSI) approach based on 95% prediction intervals or a pre-set commutability criterion and the recently introduced International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approach based on differences in bias for the clinical and reference material samples using a commutability criterion of 8.8%. All three SRMs were deemed as commutable with all LC-MS/MS assays using both CLSI and IFCC approaches. SRM 2969 and SRM 2970 were deemed noncommutable for three and seven different ligand binding assays, respectively, when using the IFCC approach. Except for two assays, one or more of the three pregnancy levels of SRM 1949 were deemed noncommutable or inconclusive using different ligand binding assays and the commutability criterion of 8.8%. Overall, a noncommutable assessment for ligand binding assays is determined for these SRMs primarily due to a lack of assay selectivity related to 25(OH)D2 or an increasing VDBP in pregnancy trimester materials rather than the quality of the SRMs. With results from 17 different ligand binding and nine LC-MS/MS assays, this study provides valuable knowledge for clinical laboratories to inform SRM selection when assessing 25(OH)D status in patient populations, particularly in subpopulations with low levels of 25(OH)D, high levels of 25(OH)D2, women only, or women who are pregnant.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信