Wan-Tong Zhou, Xi-Jin Du, Zhi-Lin Luo, Lian-Yi Xu, Ying-Guang Cao, Ke Song
{"title":"Comparative accuracy assessment of analog and virtual wax-up in prosthetic-driven planning and guided implant surgery: A retrospective cohort study.","authors":"Wan-Tong Zhou, Xi-Jin Du, Zhi-Lin Luo, Lian-Yi Xu, Ying-Guang Cao, Ke Song","doi":"10.2186/jpr.JPR_D_24_00053","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This retrospective cohort study evaluated the accuracy of analog versus virtual wax-ups in prosthetic-driven planning and guided surgery.</p><p><strong>Methods: </strong>There were 73 patients with a single missing posterior tooth who underwent either an analog or virtual wax-up design following a prosthetic-driven concept. Intraoral scans of the final restoration were performed 1 year after completion of the restoration. The accuracy was assessed by comparing the deviation between the final restoration and the wax-up (analog or virtual) of each patient at the prosthetic level. The maximum deviation in six areas (buccal top, buccal mid, buccal bottom, lingual top, lingual mid, and lingual bottom) was recorded. The accuracy was also assessed at the implant level by comparing the deviation between the virtual new implant position, which was redesigned based on the final restoration as the new wax-up, and the planned position. The mean deviations in the coronal, apical, angular, and depth measurements were recorded. A two-tailed independent t-test and a one-way analysis of variance were used.</p><p><strong>Results: </strong>Statistically significant differences were observed between the buccal (P = 0.03) and lingual tops (P = 0.03) at the prosthetic level. Significant differences were observed in the angular (P < 0.01) and coronal (P = 0.01) deviations at the implant level. There were smaller deviations between the analog wax-ups and final restorations regardless of the prosthetic or implant level.</p><p><strong>Conclusions: </strong>Analog wax-ups were preferable to virtual wax-ups for preoperative design in computer-guided implant surgery.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of prosthodontic research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_24_00053","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This retrospective cohort study evaluated the accuracy of analog versus virtual wax-ups in prosthetic-driven planning and guided surgery.
Methods: There were 73 patients with a single missing posterior tooth who underwent either an analog or virtual wax-up design following a prosthetic-driven concept. Intraoral scans of the final restoration were performed 1 year after completion of the restoration. The accuracy was assessed by comparing the deviation between the final restoration and the wax-up (analog or virtual) of each patient at the prosthetic level. The maximum deviation in six areas (buccal top, buccal mid, buccal bottom, lingual top, lingual mid, and lingual bottom) was recorded. The accuracy was also assessed at the implant level by comparing the deviation between the virtual new implant position, which was redesigned based on the final restoration as the new wax-up, and the planned position. The mean deviations in the coronal, apical, angular, and depth measurements were recorded. A two-tailed independent t-test and a one-way analysis of variance were used.
Results: Statistically significant differences were observed between the buccal (P = 0.03) and lingual tops (P = 0.03) at the prosthetic level. Significant differences were observed in the angular (P < 0.01) and coronal (P = 0.01) deviations at the implant level. There were smaller deviations between the analog wax-ups and final restorations regardless of the prosthetic or implant level.
Conclusions: Analog wax-ups were preferable to virtual wax-ups for preoperative design in computer-guided implant surgery.
期刊介绍:
Journal of Prosthodontic Research is published 4 times annually, in January, April, July, and October, under supervision by the Editorial Board of Japan Prosthodontic Society, which selects all materials submitted for publication.
Journal of Prosthodontic Research originated as an official journal of Japan Prosthodontic Society. It has recently developed a long-range plan to become the most prestigious Asian journal of dental research regarding all aspects of oral and occlusal rehabilitation, fixed/removable prosthodontics, oral implantology and applied oral biology and physiology. The Journal will cover all diagnostic and clinical management aspects necessary to reestablish subjective and objective harmonious oral aesthetics and function.
The most-targeted topics:
1) Clinical Epidemiology and Prosthodontics
2) Fixed/Removable Prosthodontics
3) Oral Implantology
4) Prosthodontics-Related Biosciences (Regenerative Medicine, Bone Biology, Mechanobiology, Microbiology/Immunology)
5) Oral Physiology and Biomechanics (Masticating and Swallowing Function, Parafunction, e.g., bruxism)
6) Orofacial Pain and Temporomandibular Disorders (TMDs)
7) Adhesive Dentistry / Dental Materials / Aesthetic Dentistry
8) Maxillofacial Prosthodontics and Dysphagia Rehabilitation
9) Digital Dentistry
Prosthodontic treatment may become necessary as a result of developmental or acquired disturbances in the orofacial region, of orofacial trauma, or of a variety of dental and oral diseases and orofacial pain conditions.
Reviews, Original articles, technical procedure and case reports can be submitted. Letters to the Editor commenting on papers or any aspect of Journal of Prosthodontic Research are welcomed.