Influence of pH on the release of nickel ions from fixed orthodontic appliances in artificial saliva.

Q2 Dentistry
Journal of Orthodontic Science Pub Date : 2024-11-25 eCollection Date: 2024-01-01 DOI:10.4103/jos.jos_8_24
Youssouf Ouédraogo, Abdoul Karim Sakira, Moussa Ouédraogo, Issa Tapsoba, Tarcissus Konsem, Jean Bertin Beugré
{"title":"Influence of pH on the release of nickel ions from fixed orthodontic appliances in artificial saliva.","authors":"Youssouf Ouédraogo, Abdoul Karim Sakira, Moussa Ouédraogo, Issa Tapsoba, Tarcissus Konsem, Jean Bertin Beugré","doi":"10.4103/jos.jos_8_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study was to make a laboratory assessment of pH influence on the kinetics of the release of nickel ions in artificial saliva.</p><p><strong>Methods and material: </strong>In this study, 15 basic orthodontic appliances are immersed in 15 polyethylene tubes each containing 40 ml of artificial saliva. Tubes were divided into three sub-groups of 5 tubes depending on the pH: pH 5, pH 7 and pH 8. The release of nickel ions was measured using atomic absorption spectrometry in a sample of 5 ml of artificial saliva taken one hour, four hours and one hundred and sixty-eight hours after immersion in a water bath at 37°.</p><p><strong>Statistical analysis used: </strong>Significance threshold <i>P</i> was set at 0.05. A Student T test and the 2-way Anova test (with a Bonferoni post-test) were used respectively to compare the means.</p><p><strong>Results: </strong>The neutral pH causes a low release of nickel ions. The release kinetics of nickel ions is minimal for neutral pH, it increases when pH varies. After one hour of immersion, the nickel released did not reach the spectrometer quantification threshold as for neutral and acid pH. The alkaline pH causes an average release of nickel ions from the beginning without kinetic variation. As time passes (T3), the acidic pH causes more nickel ions release through a succession of oxidation-reduction reactions. After 168 hours, the average mass of nickel released is 0.30 µg for pH 7, 1.35 µg for pH 8 and up to 2.85 µg for pH 5.</p><p><strong>Conclusions: </strong>Quantities released did not reach nickel toxicity threshold in humans. Orthodontists must consider the potential risk of hypersensitivity due to nickel in fixed orthodontic appliances.</p>","PeriodicalId":16604,"journal":{"name":"Journal of Orthodontic Science","volume":"13 ","pages":"49"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11698249/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthodontic Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jos.jos_8_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of this study was to make a laboratory assessment of pH influence on the kinetics of the release of nickel ions in artificial saliva.

Methods and material: In this study, 15 basic orthodontic appliances are immersed in 15 polyethylene tubes each containing 40 ml of artificial saliva. Tubes were divided into three sub-groups of 5 tubes depending on the pH: pH 5, pH 7 and pH 8. The release of nickel ions was measured using atomic absorption spectrometry in a sample of 5 ml of artificial saliva taken one hour, four hours and one hundred and sixty-eight hours after immersion in a water bath at 37°.

Statistical analysis used: Significance threshold P was set at 0.05. A Student T test and the 2-way Anova test (with a Bonferoni post-test) were used respectively to compare the means.

Results: The neutral pH causes a low release of nickel ions. The release kinetics of nickel ions is minimal for neutral pH, it increases when pH varies. After one hour of immersion, the nickel released did not reach the spectrometer quantification threshold as for neutral and acid pH. The alkaline pH causes an average release of nickel ions from the beginning without kinetic variation. As time passes (T3), the acidic pH causes more nickel ions release through a succession of oxidation-reduction reactions. After 168 hours, the average mass of nickel released is 0.30 µg for pH 7, 1.35 µg for pH 8 and up to 2.85 µg for pH 5.

Conclusions: Quantities released did not reach nickel toxicity threshold in humans. Orthodontists must consider the potential risk of hypersensitivity due to nickel in fixed orthodontic appliances.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthodontic Science
Journal of Orthodontic Science Dentistry-Orthodontics
CiteScore
0.90
自引率
0.00%
发文量
46
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信