Infection Diagnostics Enabled by Selective Adsorption of Breath-Based Biomarkers in Zr-Based Metal–Organic Frameworks

IF 8.2 1区 化学 Q1 CHEMISTRY, ANALYTICAL
N. Scott Bobbitt, R. Eric Sikma, Jason P. Sammon, Michael Chandross, Jacob I. Deneff, Dorina Sava Gallis
{"title":"Infection Diagnostics Enabled by Selective Adsorption of Breath-Based Biomarkers in Zr-Based Metal–Organic Frameworks","authors":"N. Scott Bobbitt, R. Eric Sikma, Jason P. Sammon, Michael Chandross, Jacob I. Deneff, Dorina Sava Gallis","doi":"10.1021/acssensors.4c02609","DOIUrl":null,"url":null,"abstract":"Exhaled breath contains trace levels of volatile organic compounds (VOCs) that can reveal information about metabolic processes or pathogens in the body. These molecules can be used for medical diagnosis, but capturing and accurately measuring them is a significant challenge in chemical separations. A highly selective nanoporous sorbent can be used to capture target molecules from a breath sample and preconcentrate them for use in a detector. In this work, we present a combined predictive modeling–experimental validation study in which five Zr-based metal–organic frameworks (MOFs) were identified and tested. These MOFs display good selectivity for a variety of VOCs known to be indicators of viral infections such as influenza and COVID-19. We first used molecular simulation to identify promising MOF candidates that were subsequently synthesized and tested for recovery of a variety of VOCs (toluene, propanal, butanone, octane, acetaldehyde) at concentrations of 20 ppm in humid nitrogen. We show that MOF-818, PCN-777, and UiO-66 have particularly good selectivity for the target molecules in the presence of humidity. These three MOFs each recover around 40–60% of the targets (with the exception of acetaldehyde) at up to 95% relative humidity. MOF-818 recovers 63% of butanone and 60% of toluene at 80% relative humidity. Recovery for acetaldehyde is lower across all MOFs at high humidity, but notably, MOF-808 recovers 90% of acetaldehyde at 60% humidity.","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":"34 1","pages":""},"PeriodicalIF":8.2000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c02609","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Exhaled breath contains trace levels of volatile organic compounds (VOCs) that can reveal information about metabolic processes or pathogens in the body. These molecules can be used for medical diagnosis, but capturing and accurately measuring them is a significant challenge in chemical separations. A highly selective nanoporous sorbent can be used to capture target molecules from a breath sample and preconcentrate them for use in a detector. In this work, we present a combined predictive modeling–experimental validation study in which five Zr-based metal–organic frameworks (MOFs) were identified and tested. These MOFs display good selectivity for a variety of VOCs known to be indicators of viral infections such as influenza and COVID-19. We first used molecular simulation to identify promising MOF candidates that were subsequently synthesized and tested for recovery of a variety of VOCs (toluene, propanal, butanone, octane, acetaldehyde) at concentrations of 20 ppm in humid nitrogen. We show that MOF-818, PCN-777, and UiO-66 have particularly good selectivity for the target molecules in the presence of humidity. These three MOFs each recover around 40–60% of the targets (with the exception of acetaldehyde) at up to 95% relative humidity. MOF-818 recovers 63% of butanone and 60% of toluene at 80% relative humidity. Recovery for acetaldehyde is lower across all MOFs at high humidity, but notably, MOF-808 recovers 90% of acetaldehyde at 60% humidity.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信